www.krohne.

com KROHNE 11/2002


7.02398.23.00

GR

M10 Signal converter


hazardous-duty version EEx d for variable-area flowmeters H250/H54

II2G

Fully equipped G direct sensing of float position G current output 4 ... 20 mA in two-wire technology / HART G HART communication G two galvanically isolated binary outputs with selectable function: G switch contact with NAMUR level to DIN 19234 G switch contact 24 V DC, open collector G pulse output 10 Hz G galvanically isolated binary input with function G totalizing counter reset G 3-line, 12-character alphameric display G operator control optionally by way of bar magnet (no need to open display) or keys (opened display)

Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments Communications technology Engineering systems & solutions Switches, counters, displays and recorders Heat metering Pressure and temperature

Signal converter M10


The H250/H54 variable-area flowmeter is equipped with an electronic signal converter M10 of hazardous-duty design EEx d (flameproof enclosure). There is no magnetic coupling nor pointer. The position of the float is sensed directly. The display can be adjusted using a bar magnet without having to open the front cover. Alternatively, adjustment can be done via the HART interface.

Technical Data
M10 display, general Ambient temperature (*) -25 to +75C (other temperatures on request) Protection (EN60529 / IEC 529) IP 67 General approval PTB 01 ATEX 1154 Explosion protection EEx d IIC T6 T1 / II2G Accuracy for H250 Class 1.6 to VDI / VDE 3513 Accuracy for H54 Class 1.0 to VDI / VDE 3513 (*) Display contrast diminishes outside temperature range of 0 ... 60C Current output two-wire technology (polarized) Power supply 24 V DC +/- 30% Signal output current 4 ... 20 mA (0 ... 100% flow) NAMUR failure signal 22 mA Power effect < 0.1 % Ext. resistance dependence < 0.1 % Temperature effect < 5A / K Ext. resistance / load impedance R 630 ohms at max. power R 250 ohms with HART communication Binary outputs (B1 and B2) Galvanically isolated, 720 V DC Mode Switching output with signalling current to NAMUR or Switching output open collector Configurable as switching contact open / closed or pulse output max. 10 pulses per second Switching output, NAMUR power supply 8V signalling current >3 mA limit point not crossed; <1 mA limit point crossed Switching output, open collector power 8 to 30 V DC Pmax = 500mW; Imax = 100mA Binary input (R) Galvanically isolated 720 V DC Operating mode switching input (internal totalizer reset) Configurable as active HI / active LO Voltage level 5 to 30 V DC Power consumption 1mA Pulse width (active) 500 ms Cable entry for operation, a certified flameproof cable entry is required Max. allowable process temperatures Max. permissible process permanent temperature in C Wiring 70C Wiring 80C T6 -40 +60 85 85 -40 +50 100 100 T5 -40 +60 85 100 -40 +50 135 135 T4 -40 +60 85 135 -40 +40 180 200 T3 T1 -40 +50 135 190 -40 +60 85 145 The cable glands and line entries must have the same degree of thermal stability as the connecting cable. Temperature class Ambient temperature in C

Wiring 90C 85 100 100 135 135 200 200 200

United Kingdom
KROHNE Ltd. Rutherford Drive Park Farm Industrial Estate Wellingborough, Northants NN8 6AE, UK TEL.: +44(0)19 33-408 500 FAX: +44(0)19 33-408 501 e-mail: info@krohne.co.uk
Signal converter M10

USA
KROHNE Inc. 7 Dearborn Road Peabody, MA 01960 TEL.: +1-978 535 -60 60 FAX: +1-978 535-17 20 e-mail: krohne@krohne.com

Other Countries:
KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 D-47058 Duisburg TEL.: +49(0)203-301-0 FAX: +49(0)203-301 389 e-mail: export@krohne.de