Industrial radiography
From Wikipedia, the free encyclopedia

Jump to: navigation, search

Industrial Radiography is the use of ionizing radiation to view objects in a way that cannot be seen otherwise. It is not to be confused with the use of ionizing radiation to change or modify objects; radiography's purpose is strictly viewing. Industrial radiography has grown out of engineering, and is a major element of nondestructive testing. It is a method of inspecting materials for hidden flaws by using the ability of short X-rays and Gamma rays to penetrate various materials.

Contents
[hide]

1 History 2 Applications
r

2.1 Inspection of products 2.2 Airport security 2.3 Non-intrusive Cargo Scanning (aka Non-Intrusive Inspection - NII)

3 Sources
r

3.1 X-ray sources 3.2 Radioisotope sources


s

3.2.1 Torch design of radiographic cameras 3.2.2 Cable based design of radiographic cameras

3.3 Contrast agents 3.4 Neutrons

4 Safety 5 See also 6 References 7 External links

[edit] History
http://en.wikipedia.org/wiki/Industrial_radiography (1 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

Radiography started in 1895 with the discovery of X-rays (later also called Rntgen rays after the man who first described their properties in detail), a type of electromagnetic radiation. Soon after the discovery of X-rays, radioactivity was discovered. By using radioactive sources such as radium, far higher photon energies could be obtained than those from normal X-ray machines. Soon these found various applications, with one of the earliest users being Loughborough University , from helping to fit shoes, more lasting medical uses and the examination of nonliving objects. X-rays and gamma-rays were put to use very early, before the dangers of ionising radiation were discovered. After World War II new isotopes such as caesium-137, iridium-192 and cobalt-60 became available for industrial radiography, and the use of radium and radon decreased.
[1]

[edit] Applications
[edit] Inspection of products

GemX-160 - Portable Wireless Controlled Battery Powered X-ray Generator for use in Non Destructive Testing and Security.

Gamma radiation sources, most commonly Iridium-192 and Cobalt-60, are used to inspect a variety of materials. The vast majority of radiography concerns the testing and grading of welds on pressurized piping, pressure vessels, high-capacity storage containers, pipelines, and some structural welds. Other tested materials include concrete (locating rebar or conduit), welder's test coupons, machined parts, plate metal, or pipewall (locating anomalies due to corrosion or mechanical damage). Non-metal components such as ceramics used in the aerospace industries are also regularly tested. Theoretically, industrial radiographers could radiograph any solid, flat material (walls, ceilings, floors, square or rectangular containers) or any hollow cylindrical or spherical object.

For purposes of inspection, including weld inspection, there exist several exposure arrangements.

First, there is the panoramic, one of the four single wall exposure/single wall view (SWE/SWV) arrangements. This exposure is created when the radiographer places the source of radiation at the center of a sphere, cone, or cylinder (including tanks, vessels, and piping). Depending

http://en.wikipedia.org/wiki/Industrial_radiography (2 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

upon client requirements, the radiographer would then place film cassettes on the outside of the surface to be examined. This exposure arrangement is ideal - when properly arranged and exposed, all portions of all exposed film will be of the same approximate density. It also has the advantage of taking less time than other arrangements since the source must only penetrate the total wall thickness (WT) once and must only travel the radius of the inspection item, not its full diameter. The major disadvantage of the panoramic is that it may be impractical to reach the center of the item (enclosed pipe) or the source may be too weak to perform in this arrangement (large vessels or tanks).

The second SWE/SWV arrangement is an interior placement of the source in an enclosed inspection item without having the source centered up. The source does not come in direct contact with the item, but is placed a distance away, depending on client requirements. The third is an exterior placement with similar characteristics. The fourth is reserved for flat objects, such as plate metal, and is also radiographed without the source coming in direct contact with the item. In each case, the radiographic film is located on the opposite side of the inspection item from the source. In all four cases, only one wall is exposed, and only one wall is viewed on the radiograph.

Of the other exposure arrangements, only the contact shot has the source located on the inspection item. This type of radiograph exposes both walls, but only resolves the image on the wall nearest the film. This exposure arrangement takes more time than a panoramic, as the source must penetrate the WT twice and travel the entire outside diameter of the pipe or vessel to reach the film on the opposite side. This is a double wall exposure/single wall view DWE/SWV arrangement. Another is the superimposure (wherein the source is placed on one side of the item, not in direct contact with it, with the film on the opposite side). This arrangement is usually reserved for very small diameter piping or parts. The last DWE/SWV exposure arrangement is the elliptical, in which the source is offset from the plane of the inspection item (usually a weld in pipe) and the elliptical image of the weld furthest from the source is cast onto the film.

The beam of radiation must be directed to the middle of the section under examination and must be normal to the material surface at that point, except in special techniques where known defects are best revealed by a different alignment of the beam. The length of weld under examination for each exposure shall be such that the thickness of the material at the diagnostic extremities, measured in the direction of the incident beam, does not exceed the actual thickness at that point by more than 6%. The specimen to be inspected is placed between the source of radiation and the detecting device, usually the film in a light tight holder or cassette, and the radiation is allowed to penetrate the part for the required length of time to be adequately recorded. Lead is often placed behind the film to reduce the 'back scattered' radiation which can lead to the film becoming over exposed.

The result is a two-dimensional projection of the part onto the film, producing a latent image of varying densities according to the amount of radiation reaching each area. It is known as a radiograph, as distinct from a photograph produced by light. Because film is cumulative in its response (the exposure increasing as it absorbs more radiation), relatively weak radiation can be detected by prolonging the exposure until the film can record an image that will be visible after development. The radiograph is examined as a negative, without printing as a positive as in

http://en.wikipedia.org/wiki/Industrial_radiography (3 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

photography. This is because, in printing, some of the detail is always lost and no useful purpose is served.

Before commencing a radiographic examination, it is always advisable to examine the component with one's own eyes, to eliminate any possible external defects. If the surface of a weld is too irregular, it may be desirable to grind it to obtain a smooth finish, but this is likely to be limited to those cases in which the surface irregularities (which will be visible on the radiograph) may make detecting internal defects difficult.

After this visual examination, the operator will have a clear idea of the possibilities of access to the two faces of the weld, which is important both for the setting up of the equipment and for the choice of the most appropriate technique.

[edit] Airport security


Both hold luggage and carry-on hand luggage are normally examined by X-ray machines using X-ray radiography. See airport security for more details.

[edit] Non-intrusive Cargo Scanning (aka Non-Intrusive Inspection - NII)

Gamma-ray Image of intermodal cargo container with stowaways

Gamma Radiography and High-Energy X-ray radiography are currently used to scan intermodal freight cargo containers in US and other countries. Also research is being done on adapting other types of radiography like Dual-Energy X-ray Radiography or Muon Radiography for scanning intermodal cargo containers.

[edit] Sources
[edit] X-ray sources
A high energy X-ray machine can be used. It is often important to use a high accelerating voltage to provide the electrons with a very high energy. This is because in a braking radiation source the maximum photon energy is determined by the energy of the charged particles.

[edit] Radioisotope sources


These have the advantage that they do not need a supply of electrical power to function, but they do have the disadvantage that they can not be
http://en.wikipedia.org/wiki/Industrial_radiography (4 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

turned off. Also it is difficult using radioactivity to create a small and compact source that offers the photon flux possible with a normal sealed X-ray tube. One of the leading makers of radiographic equipment is the Source Production & Equipment Co., Inc. [1]

It might be possible to use Cs-137 as a photon source for radiography but this isotope is always diluted with inactive caesium isotopes. This makes it difficult to get a physically small source, and a large volume of the source makes it impossible to capture fine details in a radiographic examination.

Both cobalt-60 and caesium-137 have only a few gamma energies, which makes them close to monochromatic. The photon energy of cobalt60 is higher than that of caesium-137, which allows cobalt sources to be used to examine thicker sections of metals than those that could be examined with Cs-137. Iridium-192 has a lower photon energy than cobalt-60 and its gamma spectrum is complex (many lines of very different energies), but this can be an advantage as this can give better contrast for the final photographs.

It has been known for many years that an inactive iridium or cobalt metal object can be machined to size. In the case of cobalt it is common to alloy it with nickel to improve the mechanical properties. In the case of iridium a thin wire or rod could be used. These precursor materials can then be placed in stainless steel containers that have been leak tested before being converted into radioactive sources. These objects can be processed by neutron activation to form gamma emitting radioisotopes. The stainless steel has only a small ability to be activated and the small activity due to 55Fe and 63Ni are unlikely to pose a problem in the final application because these isotopes are beta emitters, which have very weak gamma emission. The 59Fe which might form has a short half life, so by allowing a cobalt source to stand for a year much of this isotope will decay away.

The source is often a very small object, which must be transported to the work site in a shielded container. It is normal to place the film in industrial radiography, clear the area where the work is to be done, add shielding (collimators) to reduce the size of the controlled area before exposing the radioactive source. A series of different designs have been developed for radiographic "cameras". Rather than the "camera" being a device that accepts photons to record a picture, the "camera" in industrial radiography is the radioactive photon source.

[edit] Torch design of radiographic cameras

One design is best thought of as being like a torch. The radioactive source is placed inside a shielded box, a hinge allows part of the shielding to be opened exposing the source, allowing photons to exit the radiography camera.

http://en.wikipedia.org/wiki/Industrial_radiography (5 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

This torch-type camera uses a hinge. The radioactive source is in red, the shielding is blue/green, and the gamma rays are yellow.

Another design for a torch is where the source is placed in a metal wheel, which can turn inside the camera to move between the expose and storage positions.

This torch-type camera uses a wheel design. The radioactive source is in red, and the gamma rays are yellow.

[edit] Cable based design of radiographic cameras

One group of designs use a radioactive source, which connects to a drive cable contained shielded exposure device. In one design of equipment the source is stored in a block of lead or depleted uranium shielding that has a S shaped tube-like hole through the block. In the safe position the source is in the centre of the block and is attached to a metal wire that extends in both directions, to use the source a guide tube is attached to one side of the device while a drive cable is attached to the other end of the short cable. Using a hand operated winch the source is then pushed out of the shield and along the source guide tube to the tip of the tube to expose the film, then cranked back into its fully-shielded position.

http://en.wikipedia.org/wiki/Industrial_radiography (6 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

A diagram of the S shaped hole through a metal block; the source is stored at point A and is driven out on a cable through a hole to point B. It often goes a long way along a guide tube to where it is needed.

[edit] Contrast agents


Defects such as delaminations and planar cracks are difficult to detect using radiography, which is why penetrants are often used to enhance the contrast in the detection of such defects. Penetrants used include silver nitrate, zinc iodide, chloroform and diiodomethane. Choice of the penetrant is determined by the ease with which it can penetrate the cracks and also with which it can be removed. Diiodomethane has the advantages of high opacity, ease of penetration, and ease of removal because it evaporates relatively quickly. However, it can cause skin burns.

[edit] Neutrons
In some rare cases, radiography is done with neutrons. This type of radiography is called neutron radiography (NR, Nray, N-Ray) or neutron imaging. Neutron radiography can see very different things than X-rays, because neutrons can pass with ease through lead and steel but are stopped by plastics, water and oils. Neutron sources include radioactive (241Am/Be and Cf) sources, electrically driven D-T reactions in vacuum tubes and conventional critical nuclear reactors. It might be possible to use a neutron amplifier to increase the neutron flux.[2]

Since the amount of radiation emerging from the opposite side of the material can be detected and measured, variations in this amount (or intensity) of radiation are used to determine thickness or composition of material. Penetrating radiations are those restricted to that part of the electromagnetic spectrum of wavelength less than about 10 nanometres.

[edit] Safety
Industrial radiographers are in many locations required by governing authorities to use certain types of safety equipment and to work in pairs. Depending on location industrial radiographers may have been required to obtain permits, licences and/or undertake special training. Prior to conducting any testing the nearby area should always first be cleared of all other persons and measures taken to ensure that people do not accidentally enter into an area that may expose them to a large dose of radiation.

The safety equipment usually includes four basic items: a radiation survey meter (such as a Geiger/Mueller counter), an alarming dosimeter or rate meter, a gas-charged dosimeter, and a film badge or thermoluminescent dosimeter (TLD). The easiest way to remember what each of these items does is to compare them to gauges on an automobile.

http://en.wikipedia.org/wiki/Industrial_radiography (7 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

The survey meter could be compared to the speedometer, as it measures the speed, or rate, at which radiation is being picked up. When properly calibrated, used, and maintained, it allows the radiographer to see the current exposure to radiation at the meter. It can usually be set for different intensities, and is used to prevent the radiographer from being overexposed to the radioactive source, as well as for verifying the boundary that radiographers are required to maintain around the exposed source during radiographic operations.

The alarming dosimeter could be most closely compared with the tachometer, as it alarms when the radiographer "redlines" or is exposed to too much radiation. When properly calibrated, activated, and worn on the radiographer's person, it will emit an alarm when the meter measures a radiation level in excess of a preset threshold. This device is intended to prevent the radiographer from inadvertently walking up on an exposed source.

The gas-charged dosimeter is like a trip meter in that it measures the total radiation received, but can be reset. It is designed to help the radiographer measure his/her total periodic dose of radiation. When properly calibrated, recharged, and worn on the radiographer's person, it can tell the radiographer at a glance how much radiation to which the device has been exposed since it was last recharged. Radiographers in many states are required to log their radiation exposures and generate an exposure report. In many countries personal dosimeters are not required to be used by radiographers as the dose rates they show are not always correctly recorded.

The film badge or TLD is more like a car's odometer. It is actually a specialized piece of radiographic film in a rugged container. It is meant to measure the radiographer's total exposure over time (usually a month) and is used by regulating authorities to monitor the total exposure of certified radiographers in a certain jurisdiction. At the end of the month, the film badge is turned in and is processed. A report of the radiographer's total dose is generated and is kept on file.

When these safety devices are properly calibrated, maintained, and used, it is virtually impossible for a radiographer to be injured by a radioactive overexposure. Sadly, the elimination of just one of these devices can jeopardize the safety of the radiographer and all those who are nearby. Without the survey meter, the radiation received may be just below the threshold of the rate alarm, and it may be several hours before the radiographer checks the dosimeter, and up to a month or more before the film badge is developed to detect a low intensity overexposure. Without the rate alarm, one radiographer may inadvertently walk up on the source exposed by the other radiographer. Without the dosimeter, the radiographer may be unaware of an overexposure, or even a radiation burn, which may take weeks to result in noticeable injury. And without the film badge, the radiographer is deprived of an important tool designed to protect him or her from the effects of a long-term overexposure to occupationally-obtained radiation, and thus may suffer long-term health problems as a result.

There are three ways a radiographer will ensure they are not exposed to higher than required levels of radiation, time, distance, shielding. The less time that a person is exposed to radiation the lower their dose will be. The further a person is from a radioactive source the lower the level of radiation they receive, this is largely due to the inverse square law. Lastly the more a radioactive source is shielded by either better or
http://en.wikipedia.org/wiki/Industrial_radiography (8 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

greater amounts of shielding the lower the levels of radiation that will escape from the testing area. The most commanly used shielding materials in use are sand, lead (sheets or shot), steel, spent (non-radioactive uranium) tungsten and in suitable situations water.

Industrial radiography appears to have one of the worst safety profiles of the radiation professions, possibly because there are many operators using strong gamma sources (> 2 Ci) in remote sites with little supervision when compared with workers within the nuclear industry or within hospitals.[3] Due to the levels of radiation present whilst they are working many radiographers are also required to work late at night when there are few other people present as most industrial radiography is carried out 'in the open' rather than in purpose built exposure booths or rooms. Fatigue, carelessness and lack of proper training are the three most comman factors attributed to industrial radiography accidents. Many of the "lost source" accidents commented on by the International Atomic Energy Agency involve radiography equipment. Lost source accidents have the potential to cause a considerable loss of human life. One scenario is that a passerby finds the radiography source and not knowing what it is, takes it home.[4] The person shortly afterwards becomes ill and dies as a result of the radiation dose. The source remains in their home where it continues to irradiate other members of the household.[5] Such an event occurred in March 1984 in Casablanca (Mohammedia), which is part of Morocco. This is related to the more famous Goinia accident, where a related chain of events caused members of the public to be exposed to radiation sources. Also see List of civilian radiation accidents.

[edit] See also


q

Radiographic testing Collimator Industrial CT scanning

[edit] References
1. ^ http://www.lboro.ac.uk/library/new/Spotlighton-Archive.html Loughborough University Library - Spotlight Archive [Accessed 22 October 2008]

[edit] External links


q

NIST's XAAMDI: X-Ray Attenuation and Absorption for Materials of Dosimetric Interest Database NIST's XCOM: Photon Cross Sections Database NIST's FAST: Attenuation and Scattering Tables A lost industrial radiography source event UN information on the security of industrial sources

Rate this page


http://en.wikipedia.org/wiki/Industrial_radiography (9 of 11)21-09-2011 10:30:49

View page ratings

Industrial radiography - Wikipedia, the free encyclopedia

What's this? Trustworthy Objective Complete Well-written

I am highly knowledgeable about this topic (optional) Submit ratings

Categories: Nondestructive testing | Radiography | Loughborough University | Casting (manufacturing)


Personal tools
q

Log in / create account

Namespaces
q q

Article Discussion

Variants Views
q q q

Read Edit View history

Actions Search

Search

Interaction

Toolbox

Print/export

Languages

q q

This page was last modified on 22 August 2011 at 20:45. Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. See Terms of use for details.

http://en.wikipedia.org/wiki/Industrial_radiography (10 of 11)21-09-2011 10:30:49

Industrial radiography - Wikipedia, the free encyclopedia

Wikipedia is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization. Contact us Privacy policy About Wikipedia Disclaimers Mobile view

q q q q

http://en.wikipedia.org/wiki/Industrial_radiography (11 of 11)21-09-2011 10:30:49

Radiation: Production for Industrial Radiography

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Production of Radiation for Industrial Radiography


Industrial radiography uses two sources of radiation: X-radiation and Gamma radiation. X-rays and Gamma rays differ only in their source of origin. X-rays are produced by an X-ray generator, and Gamma radiation is the product of radioactive atoms. An in depth discussion on radiation production can be found in other areas of this site, but will be reviewed briefly in the following sections. Production of X-Rays There are two different atomic processes that can produce Xray photons. One process produces Bremsstrahlung radiation and the other produces K-shell or characteristic emission. Both processes involve a change in the energy state of electrons. Xrays are generated when an electron is accelerated and then made to rapidly decelerate, usually due to interaction with other atomic particles. In an X-ray system, a large amount of electric current is passed through a tungsten filament, which heats the filament to several thousand degrees centigrade to create a source of free electrons. A large electrical potential is established between the filament (the cathode) and a target (the anode). The cathode and anode are enclosed in a vacuum tube to prevent the filament from burning up and to prevent arcing between the cathode and anode. The electrical potential between the cathode and the anode pulls electrons from the cathode and accelerates them as they are attracted towards the anode or target, which is usually made of tungsten. X-rays are generated when free electrons give up some of their energy when they interact with the electrons or nucleus of an atom. The interaction of the electrons in the target results in the emission of a continuous Bremsstrahlung spectrum and also characteristic X-rays from the target material. Production of Gamma Rays Gamma radiation is the product of radioactive atoms. Depending upon the ratio of neutrons to protons within its nucleus, an isotope of a particular element may be stable or unstable. Over time, the nuclei of unstable isotopes spontaneously disintegrate, or transform, in a process known as radioactive decay. Various types of radiation may be emitted from the nucleus and/or its surrounding electrons when an atom experiences radioactive decay. Nuclides which undergo radioactive decay are called radionuclides. Any material which contains measurable amounts of one or more radionuclides is a radioactive material.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/production.htm (1 of 3)21-09-2011 10:36:33

Radiation: Production for Industrial Radiography

Dosimeter Video Clips References Quizzes

There are many naturally occurring radioactive materials, but manmade radioactive isotopes or radioisotopes are used for industrial radiography. Man-made sources are produced by introducing an extra neutron to atoms of the source material. For example, Cobalt-60 is produced by bombarding a sample of Cobalt-59 with an excess of neutrons in a nuclear reactor. The Cobalt-59 atoms absorb some of the neutrons and increase their atomic weight by one to produce the radioisotope Cobalt-60. This process is known as activation. As a material rids itself of atomic particles to return to a balance state, energy is released in the form of Gamma rays and sometimes alpha or beta particles. Physical size of isotope materials will very slightly between manufacturer, but generally an isotope is a pellet that measures 1.5 mm x 1.5 mm. Depending on the activity (curies) desired, a pellet or pellets are loaded into a stainless steel capsule and sealed. Unlike X-ray tubes, radioactive sources provide a continual source of radiation that cannot be turned off. Once radioactive decay starts, it continues until all of the atoms have reached a stable state. The radioisotope can only be shielded to prevent exposure to the radiation. In industrial radiography, the instruments that are used to shield the radioisotope so that they can be safely handled and used are commonly called cameras or exposure devices. Exposure devices will be discussed later in more detail.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/production.htm (2 of 3)21-09-2011 10:36:33

Radiation: Production for Industrial Radiography

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/production.htm (3 of 3)21-09-2011 10:36:33

Radiation: Decay and Half-life

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns

Radioactive Decay and Half-Life

As mentioned previously, radioactive decay is the disintegration of an unstable atom with an accompanying emission of radiation. As a radioisotope atom decays to a more stable atom, it emits radiation only once. To change from an unstable atom to a completely stable atom may require several Radiation Theory Nature of Radiation disintegration steps and radiation will be given off at each step. However, once the atom reaches a Sources of High Energy stable configuration, no more radiation is given off. For this reason, radioactive sources become Rad weaker with time. As more and more unstable atoms become stable atoms, less radiation is produced Rad for Ind Radiography and eventually the material will become non-radioactive. Decay and Half-life
Energy, Activity, Intensity and Exposure The decay of radioactive elements occurs at a fixed rate. The half-life of a radioisotope is the time Interaction with Matter required for one half of the amount of unstable material to degrade into a more stable material. For example, a source will have an intensity of 100% when new. At one half-life, its intensity will be cut Ionization Radiosensitivity to 50% of the original intensity. At two half-lives, it will have an intensity of 25% of a new source. Measures Related to After ten half-lives, less than one-thousandth of the original activity will remain. Although the halfBiological Effects life pattern is the same for every radioisotope, the length of a half-life is different. For example, Co-60 Biological Effects has a half-life of about 5 years while Ir-192 has a half-life of about 74 days.

Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/decay.htm (1 of 2)21-09-2011 10:40:06

Radiation: Decay and Half-life

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/decay.htm (2 of 2)21-09-2011 10:40:06

Radiation: Activity and Intensity

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects

Energy, Activity, Intensity and Exposure


Different radioactive materials and X-ray generators produce radiation at different energy levels and at different rates. It is important to understand the terms used to describe the energy and intensity of the radiation. The four terms used most for this purpose are: energy, activity, intensity and exposure. Radiation Energy As mentioned previously, the energy of the radiation is responsible for its ability to penetrate matter. Higher energy radiation can penetrate more and higher density matter than low energy radiation. The energy of ionizing radiation is measured in electronvolts (eV). One electronvolt is an extremely small amount of energy so it is common to use kiloelectronvolts (keV) and megaelectronvolt (MeV). An electronvolt is a measure of energy, which is different from a volt which is a measure of the electrical potential between two positions. Specifically, an electronvolt is the kinetic energy gained by an electron passing through a potential difference of one volt. X-ray generators have a control to adjust the keV or the kV.

The energy of a radioisotope is a characteristic of the atomic structure of the material. Consider, for Biological Effects Biological Factors example, Iridium-192 and Cobalt-60, which are two of the more common industrial Gamma ray sources. These isotopes emit radiation in two or three discreet wavelengths. Cobalt-60 will emit 1.33 Stochastic (Delayed) Effects and 1.17 MeV Gamma rays, and Iridium-192 will emit 0.31, 0.47, and 0.60 MeV Gamma rays. It can -Cancer be seen from these values that the energy of radiation coming from Co-60 is about twice the energy of -Leukemia -Genetic Effects the radiation coming from the Ir-192. From a radiation safety point of view, this difference in energy -Cataracts is important because the Co-60 has more material penetrating power and, therefore, is more dangerous Nonstochastic (Acute) and requires more shielding. Effects
Symptoms

Activity The strength of a radioactive source is called its activity, which is defined as the rate at which the isotope decays. Specifically, it is the number of atoms that decay and emit radiation in one second. Radioactivity may be thought of as the volume of radiation produced in a given amount of time. It is similar to the current control on a X-ray generator. The International System (SI) unit for activity is the becquerel (Bq), which is that quantity of radioactive material in which one atom transforms per second. The becquerel is a small unit. In practical situations, radioactivity is often quantified in kilobecqerels (kBq) or megabecquerels (MBq). The curie (Ci) is also commonly used as the unit for activity of a particular source material. The curie is a quantity of radioactive
http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/activity.htm (1 of 2)21-09-2011 10:44:17

Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Radiation: Activity and Intensity

material in which 3.7 x 1010 atoms disintegrate per second. This is approximately the amount of radioactivity emitted by one gram (1 g) of Radium 226. One curie equals approximately 37,037 MBq. New sources of cobalt will have an activity of 20 to over 100 curies, and new sources of iridium will have an activity of similar amounts. Once a radioactive nucleus decays, it is no longer possible for it to emit the same radiation again. Therefore, the activity of radioactive sources decrease with time and the activity of a given amount of radioactive material does not depend upon the mass of material present. Additionally, two one-curie sources of Cs-137 might have very different masses depending upon the relative proportion of nonradioactive atoms present in each source. The concentration of radioactivity, or the relationship between the mass of radioactive material and the activity, is called the specific activity. Specific activity is expressed as the number of curies or becquerels per unit mass or volume. The higher the specific activity of a material, the smaller the physical size of the source is likely to be. Intensity Radiation intensity is the amount of energy passing through a given area that is perpendicular to the direction of radiation travel in a given unit of time. The intensity of an X-ray or gamma-ray source can easily be measured with the right detector. Since it is difficult to measure the strength of a radioactive source based on its activity, which is the number of atoms that decay and emit radiation in one second, the strength of a source is often referred to in terms of its intensity. Measuring the intensity of a source is sampling the number of photons emitted from the source in some particular time period, which is directly related to the number of disintegrations in the same time period (the activity). Exposure One way to measure the intensity of x-rays or gamma rays is to measure the amount of ionization they cause in air. The amount of ionization in air produced by the radiation is called the exposure. Exposure is expressed in terms of a scientific unit called a roentgen (R or r). The unit roentgen is equal to the amount of radiation that produces in one cubic centimeter of dry air at 0C and standard atmospheric pressure ionization of either sign equal to one electrostatic unit of charge. Most portable radiation detection safety devices used by a radiographer measure exposure and present the reading in terms of roentgens or roentgens/hour, which is known as the dose rate.

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/activity.htm (2 of 2)21-09-2011 10:44:17

Interaction of Electromagnetic Radiation and Matter

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns

Interaction of Electromagnetic Radiation and Matter

It is well known that all matter is comprised of atoms. But subatomically, matter is made up of mostly empty space. For example, consider the hydrogen atom with its one proton, one neutron, and one electron. The diameter of a single proton has been measured to be about 10-15 meters. The diameter of Radiation Theory Nature of Radiation a single hydrogen atom has been determined to be 10-10 meters, therefore the ratio of the size of a hydrogen atom to the size of the proton is 100,000:1. Consider this in terms of something more easily Sources of High Energy Rad pictured in your mind. If the nucleus of the atom could be enlarged to the size of a softball (about 10 Rad for Ind Radiography cm), its electron would be approximately 10 kilometers away. Therefore, when electromagnetic waves Decay and Half-life pass through a material, they are primarily moving through free space, but may have a chance Energy, Activity, Intensity encounter with the nucleus or an electron of an atom. and Exposure Because the encounters of photons with atom particles are by chance, a given photon has a finite probability of passing completely through the medium it is traversing. The probability that a photon will pass completely through a medium depends on numerous factors including the photons energy and the mediums composition and thickness. The more densely packed a mediums atoms, the more likely the photon will encounter an atomic particle. In other words, the more subatomic particles in a material (higher Z number), the greater the likelihood that interactions will occur Similarly, the more material a photon must cross through, the more likely the chance of an encounter. When a photon does encounter an atomic particle, it transfers energy to the particle. The energy may be reemitted back the way it came (reflected), scattered in a different direction or transmitted forward into the material. Let us first consider the interaction of visible light. Reflection and transmission of light waves occur because the light waves transfer energy to the electrons of the material and cause them to vibrate. If the material is transparent, then the vibrations of the electrons are passed on to neighboring atoms through the bulk of the material and reemitted on the opposite side of the object. If the material is opaque, then the vibrations of the electrons are not passed from atom to atom through the bulk of the material, but rather the electrons vibrate for short periods of time and then reemit the energy as a reflected light wave. The light may be reemitted from the surface of the material at a different wavelength, thus changing its color. X-Rays and Gamma Rays X-rays and gamma rays also transfer their energy to matter though chance encounters with electrons and atomic nuclei. However, X-rays and gamma rays have enough energy to do more than just make the electrons vibrate. When these high energy rays encounter an atom, the result is an ejection of energetic electrons from the atom or the excitation of electrons. The term "excitation" is used to describe an interaction where electrons acquire energy from a passing charged particle but are not removed completely from their atom. Excited electrons may subsequently emit energy in the form of x-rays during the process of returning to a lower energy state.
Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/interaction.htm (1 of 2)21-09-2011 10:46:17

Interaction of Electromagnetic Radiation and Matter

Dosimeter Video Clips References Quizzes

Each of the excited or liberated electrons goes on to transfer its energy to matter through thousands of events involving interactions between charged particles. With each interaction, the energy may be directed in a different direction. The higher the energy of a photon, the more likely the energy will continue traveling in the same direction. As the radiation moves from point to point in matter, it loses its energy through various interactions with the atoms it encounters. If the radiation has enough energy, it may eventually make it through the material. Photon Interaction with Matter is Key From the previous paragraph, it can be deduced that the energy of X- and Gamma ray photons is largely responsible for their penetrating power. Einstein linked the energy of a photon to its frequency and wavelength when he postulated that each photon carries an energy of the frequency of the wave times Plancks constant (E = h). The frequency of an EM wave equals the speed of light divided by the wavelength ( =c/ ). However, it should be understood that the wavelength or frequency of electromagnetic radiation does not in itself makes the EM wave more or less penetrating. The key is its interaction with matter, or more specifically, whether the photon's energy is right to excite some transition of a charged particle. For instance, microwaves penetrate glass very easily, but they are strongly absorbed by water. Move up to slightly higher frequency, and infrared is strongly absorbed by both glass and water, but both substances transmit visible light. Ultraviolet is stopped by glass, but not so readily by water.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/interaction.htm (2 of 2)21-09-2011 10:46:17

Ionization

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Ionization and Cell Damage


As previously discussed, photons that interact with atomic particles can transfer their energy to the material and break chemical bonds in materials. This interaction is known as ionization and involves the dislodging of one or more electrons from an atom of a material. This creates electrons, which carry a negative charge, and atoms without electrons, which carry a positive charge. Ionization in industrial materials is usually not a big concern. In most cases, once the radiation ceases the electrons rejoin the atoms and no damage is done. However, ionization can disturb the atomic structure of some materials to a degree where the atoms enter into chemical reactions with each other. This is the reaction that takes place in the silver bromide of radiographic film to produce a latent image when the film is processed. Ionization may cause unwanted changes in some materials, such as semiconductors, so that they are no longer effective for their intended use. Ionization in Living Tissue (Cell Damage) In living tissue, similar interactions occur and ionization can be very detrimental to cells. Ionization of living tissue causes molecules in the cells to be broken apart. This interaction can kill the cell or cause them to reproduce abnormally. Damage to a cell can come from direct action or indirect action of the radiation. Cell damage due to direct action occurs when the radiation interacts directly with a cell's essential molecules (DNA). The radiation energy may damage cell components such as the cell walls or the deoxyribonucleic acid (DNA). DNA is found in every cell and consists of molecules that determine the function that each cell performs. When radiation interacts with a cell wall or DNA, the cell either dies or becomes a different kind of cell, possibly even a cancerous one. Cell damage due to indirect action occurs when radiation interacts with the water molecules, which are roughly 80% of a cells composition. The energy absorbed by the water molecule can result in the formation of free radicals. Free radicals are molecules that are highly reactive due to the presence of unpaired electrons, which result when water molecules are split. Free radicals may form compounds, such as hydrogen peroxide, which may initiate harmful chemical reactions within the cells. As a result of these chemical changes, cells may undergo a variety of structural changes which lead to altered function or cell death. Various possibilities exist for the fate of cells damaged by radiation. Damaged cells can:
q q

completely and perfectly repair themselves with the body's inherent repair mechanisms. die during their attempt to reproduce. Thus, tissues and organs in which there is substantial cell loss may become functionally impaired. There is a "threshold" dose for each organ and tissue above which functional impairment will manifest as a clinically observable adverse outcome. Exceeding the threshold dose increases the level of harm. Such outcomes are called

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/ionization.htm (1 of 2)21-09-2011 10:46:44

Ionization

deterministic effects and occur at high doses. repair themselves imperfectly and replicate this imperfect structure. These cells, with the progression of time, may be transformed by external agents (e.g., chemicals, diet, radiation exposure, lifestyle habits, etc.). After a latency period of years, they may develop into leukemia or a solid tumor (cancer). Such latent effects are called stochastic (or random).

Dosimeter Video Clips References Quizzes

Exposure of Living Tissue to Non-ionizing Radiation A quick note of caution about non-ionizing radiation is probably also appropriate here. Non-ionizing radiation behaves exactly like ionizing radiation, but differs in that it has a much greater wavelength and, therefore, less energy. Although this non-ionizing radiation does not have the energy to create ion pairs, some of these waves can cause personal injury. Anyone who has received a sunburn knows that ultraviolet light can damage skin cells. Non-ionizing radiation sources include lasers, highintensity sources of ultraviolet light, microwave transmitters and other devices that produce high intensity radio-frequency radiation.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/ionization.htm (2 of 2)21-09-2011 10:46:44

Radiosensitivity

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns

Cell Radiosensitivity

Radiosensitivity is the relative susceptibility of cells, tissues, organs, organisms, or other substances to the injurious action of radiation. In general, it has been found that cell radiosensitivity is directly Radiation Theory proportional to the rate of cell division and inversely proportional to the degree of cell differentiation. Nature of Radiation In short, this means that actively dividing cells or those not fully mature are most at risk from Sources of High Energy radiation. The most radio-sensitive cells are those which: Rad
q q q q

have a high division rate have a high metabolic rate are of a non-specialized type are well nourished

Examples of various tissues and their relative radiosensitivities are listed below. High Radiosensitivity Lymphoid organs, bone marrow, blood, testes, ovaries, intestines Fairly High Radiosensitivity Skin and other organs with epithelial cell lining (cornea, oral cavity, esophagus, rectum, bladder, vagina, uterine cervix, ureters) Moderate Radiosensitivity Optic lens, stomach, growing cartilage, fine vasculature, growing bone Fairly Low Radiosensitivity Mature cartilage or bones, salivary glands, respiratory organs, kidneys, liver, pancreas, thyroid, adrenal and pituitary glands Low Radiosensitivity Muscle, brain, spinal cord Reference: Rubin, P. and Casarett. G. W.: Clinical Radiation Pathology (Philadelphia: W. B. Saunders. 1968).

Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/radiosensitivity.htm (1 of 2)21-09-2011 10:47:09

Radiosensitivity

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/radiosensitivity.htm (2 of 2)21-09-2011 10:47:09

Rad Units

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Measures Relative to the Biological Effect of Radiation Exposure


There are five measures of radiation that radiographers will commonly encounter when addressing the biological effects of working with X-rays or Gamma rays. These measures are: Exposure, Dose, Dose Equivalent, and Dose Rate A short summary of these measures and their units will be followed by more in depth information below.
q

Exposure: Exposure is a measure of the strength of a radiation field at some point in air. This is the measure made by a survey meter. The most commonly used unit of exposure is the roentgen (R). Dose or Absorbed Dose: Absorbed dose is the amount of energy that ionizing radiation imparts to a given mass of matter. In other words, the dose is the amount of radiation absorbed by and object. The SI unit for absorbed dose is the gray (Gy), but the rad (Radiation Absorbed Dose) is commonly used. 1 rad is equivalent to 0.01 Gy. Different materials that receive the same exposure may not absorb the same amount of radiation. In human tissue, one Roentgen of gamma radiation exposure results in about one rad of absorbed dose. Dose Equivalent: The dose equivalent relates the absorbed dose to the biological effect of that dose. The absorbed dose of specific types of radiation is multiplied by a "quality factor" to arrive at the dose equivalent. The SI unit is the sievert (SV), but the rem is commonly used. Rem is an acronym for "roentgen equivalent in man." One rem is equivalent to 0.01 SV. When exposed to X- or Gamma radiation, the quality factor is 1. Dose Rate: The dose rate is a measure of how fast a radiation dose is being received. Dose rate is usually presented in terms of R/hour, mR/hour, rem/hour, mrem/hour, etc.

For the types of radiation used in industrial radiography, one roentgen equals one rad and since the quality factor for x- and gamma rays is one, radiographers can consider the Roentgen, rad, and rem to be equal in value. More Information on Exposure, Dose, Dose Equivalent, and Dose Rate Exposure Exposure is a measure of the strength of a radiation field at some point. It is a measure of the ionization of the molecules in a mass of air. It is usually defined as the amount of charge (i.e. the sum of all ions of the same sign) produced in a unit mass of air when the interacting photons are completely absorbed in that mass. The most commonly used unit of exposure is the Roentgen (R). Specifically, a Roentgen is the amount of photon energy required to produce 1.610 x 1012 ion pairs in one gram of dry air at 0C. A radiation field of one Roentgen

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/Measures.htm (1 of 3)21-09-2011 10:47:40

Rad Units

will deposit 2.58 x 10-4 coulombs of charge in one kilogram of dry air. The main advantage of this unit is that it is easy to directly measure with a survey meter. The main limitation is that it is only valid for deposition in air. Dose or Absorbed Dose Whereas exposure is defined for air, the absorbed dose is the amount of energy that ionizing radiation imparts to a given mass of matter. The absorbed dose is used to relate the amount of ionization that x-rays or gamma rays cause in air to the level of biological damage that would be caused in living tissue placed in the radiation field. The most commonly used unit for absorbed dose is the rad (Radiation Absorbed Dose). A rad is defined as a dose of 100 ergs of energy per gram of the given material. The SI unit for absorbed dose is the gray (Gy), which is defined as a dose of one joule per kilogram. Since one joule equals 107 ergs, and since one kilogram equals 1000 grams, 1 Gray equals 100 rads. The size of the absorbed dose is dependent upon the the intensity (or activity) of the radiation source, the distance from the source to the irradiated material, and the time over which the material is irradiated. The activity of the source will determine the dose rate which can be expressed in rad/hr, mr/hr, mGy/sec, etc. Dose Equivalent When considering radiation interacting with living tissue, it is important to also consider the type of radiation. Although the biological effects of radiation are dependent upon the absorbed dose, some types of radiation produce greater effects than others for the same amount of energy imparted. For example, for equal absorbed doses, alpha particles may be 20 times as damaging as beta particles. In order to account for these variations when describing human health risks from radiation exposure, the quantity called dose equivalent is used. This is the absorbed dose multiplied by certain quality or adjustment factors indicative of the relative biological-damage potential of the particular type of radiation. The quality factor (Q) is a factor used in radiation protection to weigh the absorbed dose with regard to its presumed biological effectiveness. Radiation with higher Q factors will cause greater damage to tissue. The rem is a term used to describe a special unit of dose equivalent. Rem is an abbreviation for roentgen equivalent in man. The SI unit is the sievert (SV); one rem is equivalent to 0.01 SV. Doses of radiation received by workers are recorded in rems, however, sieverts are being required as the industry transitions to the SI unit system. The table below presents the Q factors for several types of radiation.

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/Measures.htm (2 of 3)21-09-2011 10:47:40

Rad Units

Type of Radiation X-Ray Gamma Ray Beta Particles Thermal Neutrons Fast Neutrons Alpha Particles

Rad 1 1 1 1 1 1

Q Factor 1 1 1 5 10 20

Rem 1 1 1 5 10 20

Dose Rate The dose rate is a measure of how fast a radiation dose is being received. Knowing the dose rate, allows the dose to be calculated for a period of time. Fore example, if the dose rate is found to be 0.8rem/hour, then a person working in this field for two hours would receive a 1.6rem dose.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/theory/Measures.htm (3 of 3)21-09-2011 10:47:40

Biological Effects

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Biological Effects
The occurrence of particular health effects from exposure to ionizing radiation is a complicated function of numerous factors including:
q

Type of radiation involved. All kinds of ionizing radiation can produce health effects. The main difference in the ability of alpha and beta particles and Gamma and X-rays to cause health effects is the amount of energy they have. Their energy determines how far they can penetrate into tissue and how much energy they are able to transmit directly or indirectly to tissues. Size of dose received. The higher the dose of radiation received, the higher the likelihood of health effects. Rate the dose is received. Tissue can receive larger dosages over a period of time. If the dosage occurs over a number of days or weeks, the results are often not as serious if a similar dose was received in a matter of minutes. Part of the body exposed. Extremities such as the hands or feet are able to receive a greater amount of radiation with less resulting damage than blood forming organs housed in the torso. See radiosensitivity page for more information. The age of the individual. As a person ages, cell division slows and the body is less sensitive to the effects of ionizing radiation. Once cell division has slowed, the effects of radiation are somewhat less damaging than when cells were rapidly dividing. Biological differences. Some individuals are more sensitive to the effects of radiation than others. Studies have not been able to conclusively determine the differences.

The effects of ionizing radiation upon humans are often broadly classified as being either stochastic or nonstochastic. These two terms are discussed more in the next few pages.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/biological.htm (1 of 2)21-09-2011 10:50:44

Biological Effects

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/biological.htm (2 of 2)21-09-2011 10:50:44

Stochastic Effects

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns

Stochastic Effects

Stochastic effects are those that occur by chance and consist primarily of cancer and genetic effects. Stochastic effects often show up years after exposure. As the dose to an individual increases, the Radiation Theory probability that cancer or a genetic effect will occur also increases. However, at no time, even for high Nature of Radiation doses, is it certain that cancer or genetic damage will result. Similarly, for stochastic effects, there is Sources of High Energy Rad no threshold dose below which it is relatively certain that an adverse effect cannot occur. In addition, Rad for Ind Radiography because stochastic effects can occur in individuals that have not been exposed to radiation above Decay and Half-life background levels, it can never be determined for certain that an occurrence of cancer or genetic Energy, Activity, Intensity damage was due to a specific exposure. While it cannot be determined conclusively, it often possible to estimate the probability that radiation exposure will cause a stochastic effect. As mentioned previously, it is estimated that the probability of having a cancer in the US rises from 20% for non radiation workers to 21% for persons who work regularly with radiation. The probability for genetic defects is even less likely to increase for workers exposed to radiation. Studies conducted on Japanese atomic bomb survivors who were exposed to large doses of radiation found no more genetic defects than what would normally occur. Radiation-induced hereditary effects have not been observed in human populations, yet they have been demonstrated in animals. If the germ cells that are present in the ovaries and testes and are responsible for reproduction were modified by radiation, hereditary effects could occur in the progeny of the individual. Exposure of the embryo or fetus to ionizing radiation could increase the risk of leukemia in infants and, during certain periods in early pregnancy, may lead to mental retardation and congenital malformations if the amount of radiation is sufficiently high. More on Specific Stochastic Effects Cancer Leukemia Genetic Effects Cataracts
and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects

Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/stochastic/stochastic.htm (1 of 2)21-09-2011 10:51:14

Stochastic Effects

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/stochastic/stochastic.htm (2 of 2)21-09-2011 10:51:14

Nonstochastic Effects

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Nonstochastic (Acute) Effects


Unlike stochastic effects, nonstochastic effects are characterized by a threshold dose below which they do not occur. In other words, nonstochastic effects have a clear relationship between the exposure and the effect. In addition, the magnitude of the effect is directly proportional to the size of the dose. Nonstochastic effects typically result when very large dosages of radiation are received in a short amount of time. These effects will often be evident within hours or days. Examples of nonstochastic effects include erythema (skin reddening), skin and tissue burns, cataract formation, sterility, radiation sickness and death. Each of these effects differs from the others in that both its threshold dose and the time over which the dose was received cause the effect (i.e. acute vs. chronic exposure). There are a number of cases of radiation burns occurring to the hands or fingers. These cases occurred when a radiographer touched or came in close contact with a high intensity radiation emitter. Intensity on the surface of an 85 curie Ir-192 source capsule is approximately 1,768 R/s. Contact with the source for two seconds would expose the hand of an individual to 3,536 rems, and this does not consider any additional whole body dosage received when approaching the source. More on Specific Nonstochastic Effects Hemopoietic Syndrome The hemopoietic syndrome encompasses the medical conditions that affect the blood. Hemopoietic syndrome conditions appear after a gamma dose of about 200 rads (2 Gy). This disease is characterized by depression or ablation of the bone marrow, and the physiological consequences of this damage. The onset of the disease is rather sudden, and is heralded by nausea and vomiting within several hours after the overexposure occurred. Malaise and fatigue are felt by the victim, but the degree of malaise does not seem to be correlated with the size of the dose. Loss of hair (epilation), which is almost always seen, appears between the second and third week after the exposure. Death may occur within one to two months after exposure. The chief effects to be noted, of course, are in the bone marrow and in the blood. Marrow depression is seen at 200 rads and at about 400 to 600 rads (4 to 6 Gy) complete ablation of the marrow occurs. In this case, however, spontaneous regrowth of the marrow is possible if the victim survives the physiological effects of the denuding of the marrow. An exposure of about 700 rads (7 Gy) or greater leads to irreversible ablation of the bone marrow. Gastrointestinal Syndrome The gastrointestinal syndrome encompasses the medical conditions that affect the stomach and the intestines. This medical condition follows a total body gamma dose of about 1000 rads (10 Gy) or greater, and is a consequence of the desquamation of the intestinal epithelium. All the signs and symptoms of hemopoietic syndrome are seen, with the addition of severe nausea, vomiting, and diarrhea which begin very soon after exposure. Death within one to two weeks after exposure is the most likely outcome. Central Nervous System A total body gamma dose in excess of about 2000 rads (20 Gy) damages the central nervous system,
http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/nonstochastic/nonstochastic.htm (1 of 2)21-09-2011 10:51:52

Nonstochastic Effects

as well as all the other organ systems in the body. Unconsciousness follows within minutes after exposure and death can result in a matter of hours to several days. The rapidity of the onset of unconsciousness is directly related to the dose received. In one instance in which a 200 msec burst of mixed neutrons and gamma rays delivered a mean total body dose of about 4400 rads (44 Gy), the victim was ataxic and disoriented within 30 seconds. In 10 minutes, he was unconscious and in shock. Vigorous symptomatic treatment kept the patient alive for 34 hours after the accident. Other Acute Effects Several other immediate effects of acute overexposure should be noted. Because of its physical location, the skin is subject to more radiation exposure, especially in the case of low energy x-rays and beta rays, than most other tissues. An exposure of about 300 R (77 mC/kg) of low energy (in the diagnostic range) x-rays results in erythema. Higher doses may cause changes in pigmentation, loss of hair, blistering, cell death, and ulceration. Radiation dermatitis of the hands and face was a relatively common occupational disease among radiologists who practiced during the early years of the twentieth century. The reproductive organs are particularly radiosensitive. A single dose of only 30 rads (300 mGy) to the testes results in temporary sterility among men. For women, a 300 rad (3 Gy) dose to the ovaries produces temporary sterility. Higher doses increase the period of temporary sterility. In women, temporary sterility is evidenced by a cessation of menstruation for a period of one month or more, depending on the dose. Irregularities in the menstrual cycle, which suggest functional changes in the reproductive organs, may result from local irradiation of the ovaries with doses smaller than that required for temporary sterilization. The eyes too, are relatively radiosensitive. A local dose of several hundred rads can result in acute conjunctivitis.

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/nonstochastic/nonstochastic.htm (2 of 2)21-09-2011 10:51:52

Exposure Symptoms

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Exposure Symptoms
Listed below are some of the probable prompt and delayed effects of certain doses of radiation when the doses are received by an individual within a twenty-four hour period. Dosages are in Roentgen Equivalent Man (Rem) 0-25 No injury evident. First detectable blood change at 5 rem. 25-50 Definite blood change at 25 rem. No serious injury. 50-100 Some injury possible. 100-200 Injury and possible disability. 200-400 Injury and disability likely, death possible. 400-500 Median Lethal Dose (MLD) 50% of exposures are fatal. 500-1,000 Up to 100% of exposures are fatal. 1,000-over 100% likely fatal. The delayed effects of radiation may be due either to a single large overexposure or continuing lowlevel overexposure. Example dosages and resulting symptoms when an individual receives an exposure to the whole body within a twenty-four hour period. 100 - 200 Rem First Day First Week Second Week Third Week Fourth Week 400 - 500 Rem First Day First Week Second Week Third Week Fourth Week

No definite symptoms No definite symptoms No definite symptoms Loss of appetite, malaise, sore throat and diarrhea Recovery is likely in a few months unless complications develop because of poor health Nausea, vomiting and diarrhea, usually in the first few hours Symptoms may continue Epilation, loss off appetite Hemorrhage, nosebleeds, inflammation of mouth and throat, diarrhea, emaciation Rapid emaciation and mortality rate around 50%

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/symptoms.htm (1 of 2)21-09-2011 10:54:37

Exposure Symptoms

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/biological/symptoms.htm (2 of 2)21-09-2011 10:54:37

Exposure Limits

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Exposure Limits
As discussed in the introduction, concern over the biological effect of ionizing radiation began shortly after the discovery of X-rays in 1895. Over the years, numerous recommendations regarding occupational exposure limits have been developed by the International Commission on Radiological Protection (ICRP) and other radiation protection groups. In general, the guidelines established for radiation exposure have had two principle objectives: 1) to prevent acute exposure; and 2) to limit chronic exposure to "acceptable" levels. Current guidelines are based on the conservative assumption that there is no safe level of exposure. In other words, even the smallest exposure has some probability of causing a stochastic effect, such as cancer. This assumption has led to the general philosophy of not only keeping exposures below recommended levels or regulation limits but also maintaining all exposure "as low as reasonable achievable" (ALARA). ALARA is a basic requirement of current radiation safety practices. It means that every reasonable effort must be made to keep the dose to workers and the public as far below the required limits as possible. Regulatory Limits for Occupational Exposure Many of the recommendations from the ICRP and other groups have been incorporated into the regulatory requirements of countries around the world. In the United States, annual radiation exposure limits are found in Title 10, part 20 of the Code of Federal Regulations, and in equivalent state regulations. For industrial radiographers who generally are not concerned with an intake of radioactive material, the Code sets the annual limit of exposure at the following: 1) the more limiting of:
q

A total effective dose equivalent of 5 rems (0.05 Sv) or The sum of the deep-dose equivalent to any individual organ or tissue other than the lens of the eye being equal to 50 rems (0.5 Sv).

2) The annual limits to the lens of the eye, to the


http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/exposure.htm (1 of 2)21-09-2011 10:56:50

Exposure Limits

skin, and to the extremities, which are:


q

Dosimeter Video Clips References

A lens dose equivalent of 15 rems (0.15 Sv) A shallow-dose equivalent of 50 rems (0.50 Sv) to the skin or to any extremity.

The shallow-dose equivalent is the external dose to the skin of the whole-body or extremities from Quizzes an external source of ionizing radiation. This value is the dose equivalent at a tissue depth of 0.007 cm averaged over and area of 10 cm2. The lens dose equivalent is the dose equivalent to the lens of the eye from an external source of ionizing radiation. This value is the dose equivalent at a tissue depth of 0.3 cm. The deep-dose equivalent is the whole-body dose from an external source of ionizing radiation. This value is the dose equivalent at a tissue depth of 1 cm. The total effective dose equivalent is the dose equivalent to the whole-body. Declared Pregnant Workers and Minors Because of the increased health risks to the rapidly developing embryo and fetus, pregnant women can receive no more than 0.5 rem during the entire gestation period. This is 10% of the dose limit that normally applies to radiation workers. Persons under the age of 18 years are also limited to 0.5rem/ year. Non-radiation Workers and the Public The dose limit to non-radiation workers and members of the public are two percent of the annual occupational dose limit. Therefore, a non-radiation worker can receive a whole body dose of no more that 0.1 rem/year from industrial ionizing radiation. This exposure would be in addition to the 0.3 rem/ year from natural background radiation and the 0.05 rem/year from man-made sources such as medical x-rays.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/exposure.htm (2 of 2)21-09-2011 10:56:50

Controlling Exposure

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Controlling Radiation Exposure


When working with radiation, there is a concern for two types of exposure: acute and chronic. An acute exposure is a single accidental exposure to a high dose of radiation during a short period of time. An acute exposure has the potential for producing both nonstochastic and stochastic effects. Chronic exposure, which is also sometimes called "continuous exposure," is long-term, low level overexposure. Chronic exposure may result in stochastic health effects and is likely to be the result of improper or inadequate protective measures. The three basic ways of controlling exposure to harmful radiation are: 1) limiting the time spent near a source of radiation, 2) increasing the distance away from the source, 3) and using shielding to stop or reduce the level of radiation.

Time The radiation dose is directly proportional to the time spent in the radiation. Therefore, a person should not stay near a source of radiation any longer than necessary. If a survey meter reads 4 mR/h at a particular location, a total dose of 4mr will be received if a person remains at that location for one hour. In a two hour span of time, a dose of 8 mR would be received. The following equation can be used to make a simple calculation to determine the dose that will be or has been received in a radiation area. Dose = Dose Rate x Time (click here for more information on using this formula) When using a gamma camera, it is important to get the source from the shielded camera to the collimator as quickly as possible to limit the time of exposure to the unshielded source. Devices that shield radiation in some directions but allow it pass in one or more other directions are known as collimators. This is illustrated in the images at the bottom of this page.
http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/controlling_exposure.htm (1 of 3)21-09-2011 10:58:08

Controlling Exposure

Dosimeter

Distance Increasing distance from the source of radiation will reduce the amount of radiation received. As radiation travels from the source, it spreads out becoming less intense. This is analogous to standing near a fire. The closer a person stands to the fire, the more intense the heat feels from the fire. This phenomenon can be expressed by an equation known as the inverse square law, which states that as the radiation travels out from the source, the dosage decreases inversely with the square of the distance. Inverse Square Law: I1/ I2 = D22/ D12

Video Clips References Quizzes

(click here for more information on using this formula) Shielding The third way to reduce exposure to radiation is to place something between the radiographer and the source of radiation. In general, the more dense the material the more shielding it will provide. The most effective shielding is provided by depleted uranium metal. It is used primarily in gamma ray cameras like the one shown below. The circle of dark material in the plastic see-through camera (below right) would actually be a sphere of depleted uranium in a real gamma ray camera. Depleted uranium and other heavy metals, like tungsten, are very effective in shielding radiation because their tightly packed atoms make it hard for radiation to move through the material without interacting with the atoms. Lead and concrete are the most commonly used radiation shielding materials primarily because they are easy to work with and are readily available materials. Concrete is commonly used in the construction of radiation vaults. Some vaults will also be lined with lead sheeting to help reduce the radiation to acceptable levels on the outside.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/controlling_exposure.htm (2 of 3)21-09-2011 10:58:08

Controlling Exposure

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/controlling_exposure.htm (3 of 3)21-09-2011 10:58:08

HVL-Shielding

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns

Half-Value Layer (Shielding)


As was discussed in the radiation theory section, the depth of penetration for a given photon energy is dependent upon the material density (atomic structure). The more subatomic particles in a material (higher Z number), the greater the likelihood that interactions will occur and the radiation will lose its energy. Therefore, the more dense a material is the smaller the depth of radiation penetration will be. Materials such as depleted uranium, tungsten and lead have high Z numbers, and are therefore very effective in shielding radiation. Concrete is not as effective in shielding radiation but it is a very common building material and so it is commonly used in the construction of radiation vaults.

Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity Since different materials attenuate radiation to different degrees, a convenient method of comparing and Exposure the shielding performance of materials was needed. The half-value layer (HVL) is commonly used Interaction with Matter for this purpose and to determine what thickness of a given material is necessary to reduce the Ionization exposure rate from a source to some level. At some point in the material, there is a level at which the Radiosensitivity radiation intensity becomes one half that at the surface of the material. This depth is known as the half- Measures Related to value layer for that material. Another way of looking at this is that the HVL is the amount of material Biological Effects

necessary to the reduce the exposure rate from a source to one-half its unshielded value. Sometimes shielding is specified as some number of HVL. For example, if a Gamma source is producing 369 R/h at one foot and a four HVL shield is placed around it, the intensity would be reduced to 23.0 R/h. Each material has its own specific HVL thickness. Not only is the HVL material dependent, but it is also radiation energy dependent. This means that for a given material, if the radiation energy changes, the point at which the intensity decreases to half its original value will also change. Below are some HVL values for various materials commonly used in industrial radiography. As can be seen from reviewing the values, as the energy of the radiation increases the HVL value also increases. Approximate HVL for Various Materials when Radiation is from a Gamma Source Half-Value Layer, mm (inch) Source Iridium-192 Cobalt-60 Concrete 44.5 (1.75) 60.5 (2.38) Steel 12.7 (0.5) 21.6 (0.85) Lead 4.8 (0.19) 12.5 (0.49) Tungsten 3.3 (0.13) 7.9 (0.31) Uranium 2.8 (0.11) 6.9 (0.27)

Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Approximate Half-Value Layer for Various Materials when Radiation is from an X-ray Source Half-Value Layer, mm (inch) Peak Voltage (kVp) Lead Concrete

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/shielding.htm (1 of 2)21-09-2011 10:58:39

HVL-Shielding

50 100 150 200 250 300 400 1000

0.06 (0.002) 0.27 (0.010) 0.30 (0.012) 0.52 (0.021) 0.88 (0.035) 1.47 (0.055) 2.5 (0.098) 7.9 (0.311)

4.32 (0.170) 15.10 (0.595) 22.32 (0.879) 25.0 (0.984) 28.0 (1.102) 31.21 (1.229) 33.0 (1.299) 44.45 (1.75)

Dosimeter Video Clips References Quizzes

Note: The values presented on this page are intended for educational purposes. Other sources of information should be consulted when designing shielding for radiation sources.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/shielding.htm (2 of 2)21-09-2011 10:58:39

Safe controls

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Safety Controls
Since X-ray and gamma radiation are not detectable by the human senses and the resulting damage to the body is not immediately apparent, a variety of safety controls are used to limit exposure. The two basic types of radiation safety controls used to provide a safe working environment are engineered and administrative controls. Engineered controls include shielding, interlocks, alarms, warning signals, and material containment. Administrative controls include postings, procedures, dosimetry, and training. Engineered Controls Engineered controls such as shielding and door interlocks are used to contain the radiation in a cabinet or a "radiation vault." Fixed shielding materials are commonly high density concrete and/or lead. Door interlocks are used to immediately cut the power to X-ray generating equipment if a door is accidentally opened when X-rays are being produced. Warning lights are used to alert workers and the public that radiation is being used. Sensors and warning alarms are often used to signal that a predetermined amount of radiation is present. Safety controls should never be tampered with or bypassed. When portable radiography is performed, it is most often not practical to place alarms or warning lights in the exposure area. Ropes and signs are used to block the entrance to radiation areas and to alert the public to the presence of radiation. Occasionally, radiographers will use battery operated flashing lights to alert the public to the presence of radiation. Portable or temporary shielding devices may be fabricated from materials or equipment located in the area of the inspection. Sheets of steel, steel beams, or other equipment may be used for temporary shielding. It is the responsibility of the radiographer to know and understand the absorption value of various materials. More information on absorption values and material properties can be found in the radiography section of this site. Administrative Controls As mentioned above, administrative controls supplement the engineered controls. These controls include postings, procedures, dosimetry, and training. It is commonly required that all areas containing X-ray producing equipment or radioactive materials have signs posted bearing the radiation symbol and a notice explaining the dangers of radiation. Normal operating procedures and emergency
http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/safety_controls.htm (1 of 2)21-09-2011 11:02:44

Safe controls

procedures must also be prepared and followed. In the US, federal law requires that any individual who is likely to receive more than 10% of any annual occupational dose limit be monitored for radiation exposure. This monitoring is accomplished with the use of dosimeters, which are discussed in the radiation safety equipment section of this material. Proper training with accompanying documentation is also a very important administrative control.

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/safety_controls.htm (2 of 2)21-09-2011 11:02:44

Responsibilities

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Responsibilities
Working safely with radiation is the responsibility of everyone involved in the use and management of radiation producing equipment and materials. Depending on the size of the organization, specific responsibilities may be assigned to various individuals and/or committees.

Radiation Safety Officer All organizations that are licensed to use ionizing radiation must have a Radiation Safety Officer. The RSO is the individual authorized by the company to serve as point of contact for all activities conducted under the scope of the authorization. The RSO ensures that radiation safety activities are being performed in accordance with approved procedures and regulatory requirements. Some of the common responsible for the RSO include:
q

q q q

Ensuring that all individuals using radiation equipment are appropriately trained and supervised. Ensuring that all individuals using the equipment have been formally authorized to use the equipment. Ensuring that all rules, regulations, and procedures for the safe use of radioactive sources and X-ray systems are observed. Ensuring that proper operating, emergency, and ALARA procedures have been developed and are available to all system users. Ensuring that accurate records of the use of the sources and equipment are maintained. Ensuring that required radiation surveys and leak tests are performed and documented. Ensuring that systems and equipment are protected from unauthorized access or removal.

The minimum qualifications, training, and experience for RSOs for industrial radiography are as follows: (1) Completion of the training and testing requirements of Sec. 34.43(a) of Part 10 of the Federal Code of Regulations, (2) 2000 hours of hands-on experience as a qualified radiographer in industrial radiographic operations, and (3) Formal training in the establishment and maintenance of a radiation protection program.
http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/responsibilities.htm (1 of 2)21-09-2011 11:03:24

Responsibilities

Dosimeter

Radiation Safety Committee Some organizations may have a Radiation Safety Committee (RSC) to assist the RSO. The RSC often provides oversight of the policies, procedures and responsibilities of an organizations radiation safety program. System Users The individuals authorized to use the X-ray producing system or gamma sources are responsible for ensuring that:
q q q q

Video Clips References Quizzes

All rules, regulations, and procedures for the safe use of the X-ray system are followed. An accurate record of the use of the system is maintained. All safety problems with the system are reported to the RSO and corrected before further use. The system is protected from unauthorized access or removal.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/responsibilities.htm (2 of 2)21-09-2011 11:03:24

Procedures

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Procedures
Written operating procedures must be developed and made available to anyone that will be working with radiation sources or X-ray producing equipment. These procedures must be specific to the equipment and its use in a particular application. Simply making the equipment manufacturers operating instructions available to workers does not satisfy this requirement. The operating procedure must be followed at all times unless written permission to deviate is received from the Radiation Safety Officer. Standard Operating Procedures As a minimum, operating procedures must include instructions for the following:
q

q q q

q q

q q

Appropriate handling and use of licensed sealed sources and radiographic exposure devices so that no person is likely to be exposed to radiation doses in excess of the established exposure limits. Methods and occasions for conducting radiation surveys. Methods for controlling access to radiographic areas. Methods and occasions for locking and securing radiographic exposure devices, transport and storage containers and sealed sources. Personnel monitoring and the use of personnel monitoring equipment. Transporting sealed sources to field locations, including packing of radiographic exposure devices and storage containers in the vehicles, placarding of vehicles when needed, and control of the sealed sources during transportation. The inspection, maintenance, and operability checks of radiographic exposure devices, survey instruments, transport containers, and storage containers. The procedure(s) for identifying and reporting defects and noncompliance. Maintenance of records.

Emergency Procedures Procedures must also be developed that guide workers in the event of an emergency. A few of the items that could be covered include:
q

q q q

Steps that must be taken immediately by radiography personnel in the event a pocket dosimeter is found to be off-scale or an alarm ratemeter alarms unexpectedly. Steps for minimizing exposure of persons in the event of an accident. The procedure for notifying proper persons in the event of an accident. Radiation Safety Radioactive source recovery procedure if licensee will perform the recovery.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/procedures.htm (1 of 2)21-09-2011 11:09:16

Procedures

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/procedures.htm (2 of 2)21-09-2011 11:09:16

Survey Technique

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Survey Technique
The majority of over exposures in industrial radiography are the result of the radiographer not knowing the location of a gamma emitter and failing to conduct a proper radiation survey. Exposure vaults are equipped with warning lights and safety interlock switches which provide a margin of safety for workers. A survey must be performed occasionally to verify that vaults are not "leaking" radiation and that the safety devices are performing properly. However, when conducting radiography with gamma emitters in the field, the radiographer must rely heavily on measurements with a survey meter since other safety devices are uncommon. A series of surveys must be taken and some of the results from these surveys must be documented when transporting and working with gamma emitters in the field. Approaching the Exposure Device A technician should be thoroughly familiar with the operation of a survey meter since proper use of the device is essential. Before removing the exposure device (camera) from storage, the calibration of the survey meter must be verified and the battery level must be checked. When approaching the exposure device to remove it from the storage location, the survey meter should be in hand and operational. The survey meter should be placed next to the exposure device to verify that the source is contained inside the projector, and to verify that the survey meter is working properly. Survey meter readings should be compared to previous readings and recorded. Transporting the Exposure Device When transporting the exposure device, it must be stowed securely in the vehicle. A lockable metal box is often bolted in the rear of the vehicle. A survey of the over pack, the outside of the vehicle, and the drivers compartment is then conducted and documented. Preparing for an Exposure Once on the job site, the exposure area will be assessed, distance calculations made for restricted area boundaries, and ropes and signs placed appropriately. Once this is complete, the radiographer is ready to remove the exposure device from its storage compartment in the vehicle. The survey meter should be monitored as the storage compartment is approached and when removing the exposure device from the compartment. Daily safety checks should then be made. Once these checks are completed, the radiographer and assistant may then move the exposure device to the exposure location. As the cranks and guide tubes are attached in preparation for the first exposure, the survey meter should be monitored. Before the source is exposed, the assistant should check the area for persons who may have crossed into the restricted area, and then move outside the rope boundary.

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/survey_techniques.htm (1 of 2)21-09-2011 11:16:45

Survey Technique

Making an Exposure The radiographer should be at the maximum distance from the exposure device that the guide tube will allow as he or she quickly cracks the source out of the exposure device and into place. As the source moves out of the exposure device, the survey meter will increase to a very high level and then reduce once the source is inside the collimator. During the exposure, the assistant will survey the established boundary to determine the levels of radiation present. If the survey meter indicates levels are higher than calculated, the boundary must be extended. Retracting the Source On retraction of the source, the radiographers will see a rise in readings as the source moves from the collimator and is retracted into the projector. When the source is inside the exposure device, the radiographer should approach it while monitoring the survey meter. If the source is properly retracted, no increase in the survey meter reading should be seen when approaching the exposure device. The exposure device should be surveyed on all sides, paying special attention to the front of the device. The entire length of the guide tube must then be surveyed. This process is repeated for each exposure. The survey results must be documented when the exposure device is returned to the vehicle for transportation, and when it is placed back into its storage location.

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege/RadiationSafety/safe_use/survey_techniques.htm (2 of 2)21-09-2011 11:16:45

Radiation Detectors

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Radiation Detectors
Instruments used for radiation measurement fall into two broad categories: - rate measuring instruments and - personal dose measuring instruments.

Rate measuring instruments measure the rate at which exposure is received (more commonly called the radiation intensity). Survey meters, audible alarms and area monitors fall into this category. These instruments present a radiation intensity reading relative to time, such as R/hr or mR/hr. An analogy can be made between these instruments and the speedometer of a car because both are measuring units relative to time. Dose measuring instruments are those that measure the total amount of exposure received during a measuring period. The dose measuring instruments, or dosimeters, that are commonly used in industrial radiography are small devices which are designed to be worn by an individual to measure the exposure received by the individual. An analogy can be made between these instruments and the odometer of a car because both are measuring accumulated units. The radiation measuring instruments commonly used in industrial radiography are described in more detail in the following pages.

http://www.ndt-ed.org/EducationResources/CommunityCollege...Safety/radiation_safety_equipment/radiation_detectors.htm (1 of 2)21-09-2011 11:20:29

Radiation Detectors

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege...Safety/radiation_safety_equipment/radiation_detectors.htm (2 of 2)21-09-2011 11:20:29

Survey Meters

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Survey Meters
The survey meter is the most important resource a radiographer has to determine the presence and intensity of radiation. A review of incident and overexposure reports indicate that a majority of these type of events occurred when a technician did not have or did not use a survey meter.

There are many different models of survey meters available to measure radiation in the field. They all basically consist of a detector and a readout display. Analog and digital displays are available. Most of the survey meters used for industrial radiography use a gas filled detector. Gas filled detectors consists of a gas filled cylinder with two electrodes. Sometimes, the cylinder itself acts as one electrode, and a needle or thin taut wire along the axis of the cylinder acts as the other electrode. A voltage is applied to the device so that the central needle or wire become an anode (+ charge) and the other electrode or cylinder wall becomes the cathode (- charge). The gas becomes ionized whenever the counter is brought near radioactive substances. The electric field created by

the potential difference between the anode and cathode causes the electrons of each ion pair to move to the anode while the positively charged gas atom is drawn to the cathode. This results in
an electrical signal that is amplified, correlated to exposure and displayed as a value.

http://www.ndt-ed.org/EducationResources/CommunityColleg...iationSafety/radiation_safety_equipment/SurveyMeters.htm (1 of 4)21-09-2011 11:21:35

Survey Meters

Dosimeter Video Clips References Quizzes

Depending on the voltage applied between the anode and the cathode, the detector may be considered an ion chamber, a proportional counter, or a Geiger-Mller (GM) detector. Each of these types of detectors have their advantages and disadvantages. A brief summary of each of these detectors follows. Ion Chamber Counter Ion chambers have a relatively low voltage between the anode and cathode, which results in a collection of only the charges produced in the initial ionization event. This type of detector produces a weak output signal that corresponds to the number of ionization events. Higher energies and intensities of radiation will produce more ionization, which will result in a stronger output voltage. Collection of only primary ions provides information on true radiation exposure (energy and intensity). However, the meters require sensitive electronics to amplify the signal, which makes them fairly expensive and delicate. The additional expense and required care is justified when it is necessary to make accurate radiation exposure measurements over a range of radiation energies. This might be necessary when measuring the Bremsstrahlung radiation produced by an X-ray generator. An ion chamber survey meter is sometimes used in the field when performing gamma radiography because it will provide accurate exposure measurements regardless of the radioactive isotope being used. Proportional Counter Proportional counter detectors use a slightly higher voltage between the anode and cathode. Due to the strong electrical field, the charges produced in the initial ionization are accelerated fast enough to ionize other electrons in the gas. The electrons produced in these secondary ion pairs, along with the primary electrons, continue to gain energy as they move towards the anode, and as they do, they produce more and more ionizations. The result is that each electron from a primary ion pair produces a cascade of ion pairs. This effect is known as gas multiplication or amplification. In this voltage regime, the number of particles liberated by secondary interactions is proportional to the number of ions produced by the passing ionizing particle. Hence, these gas ionization detectors are called proportional counters. Like ion chamber detectors, proportional detectors discriminate between types of radiation. However, they require very stable electronics which are expensive and fragile. Proportional detectors are usually only used in a laboratory setting. Geiger-Mller (GM) Counter
http://www.ndt-ed.org/EducationResources/CommunityColleg...iationSafety/radiation_safety_equipment/SurveyMeters.htm (2 of 4)21-09-2011 11:21:35

Survey Meters

Geiger-Mller counters operate under even higher voltages between the anode and the cathode, usually in the 800 to 1200 volt range. Like the proportional counter, the high voltage accelerates the charges produced in the initial ionization to where they have enough energy to ionize other electrons in the gas. However, this cascading of ion pairs occurs to a much larger degree and continues until the counter is saturated with ions. This all happens in a fraction of a second and results in an electrical current pulse of constant voltage. The collection of the large number of secondary ions in the GM region is known as an avalanche and produces a large voltage pulse. In other words, the size of the current pulse is independent of the size of the ionization event that produced it. The electronic circuit of a GM counters counts and records the number of pulses and the information is often displayed in counts per minute. If the instrument has a The GM counter was named for Hans Geiger who invented the device in 1908, and Walther Mller who collaborated with Geiger in developing it further in 1928.

speaker, the pulses can also produce an audible click. When the volume of gas in the chamber is completely ionized, ion collection stops until the electrical pulse discharges. Again, this only takes a fraction of a second, but this process slightly limits the rate at which individual events can be detected.
Because they can display individual ionizing events, GM counters are generally more sensitive to low levels of radiation than ion chamber instruments. By means of calibration, the count rate can be displayed as the exposure rate over a specified energy range. When used for gamma radiography, GM meters are typically calibrated for the energy of the gamma radiation being used. Most often, gamma radiation from Cs-137 at 0.662 MeV provides the calibration. Only small errors occur when the radiographer uses Ir-192 (average energy about 0.34 MeV) or Co-60 (average energy about 1.25 MeV).

Since the Geiger-Mller counter produces many more electrons than a ion chamber counter or a proportional counter, it does not require the same level of electronic sophistication as other survey meters. This results in a meter that is relatively low cost and rugged. The disadvantages of GM survey meters are the lack of ability to account for different amounts of ionization caused by different energy photons and noncontinuous measurement (need to discharge). Comparison of Gas Filled Detectors The graph to the right shows the relationship of ion collection in a gas filled detector versus the applied voltage. In the ion chamber region, the voltage between the anode and cathode is relatively low and only primary ions are collected. In the proportional region ,the voltage is higher, and primary ions and a number of secondary ions (proportional to the primary ions originally formed) are collected. In the GM region, a maximum number of secondary ions are collected when the gas around the anode is completely ionized. Note that discrimination between kinds of radiation (E1 and E2) is possible in the ion chamber and proportional regions. Radiation at different energy levels forms different numbers of primary ions in the detector. However in the GM region, the number of secondary ions collected per event remains the same no matter what the energy of the radiation that initiated

http://www.ndt-ed.org/EducationResources/CommunityColleg...iationSafety/radiation_safety_equipment/SurveyMeters.htm (3 of 4)21-09-2011 11:21:35

Survey Meters

the event. The GM counter gives up the ability to accurately measure the exposure due to different energies of radiation in exchange for a large signal pulse. This large signal pulse simplifies the electronics that are necessary for instruments such as survey meters.

http://www.ndt-ed.org/EducationResources/CommunityColleg...iationSafety/radiation_safety_equipment/SurveyMeters.htm (4 of 4)21-09-2011 11:21:35

Pocket Dosimeter

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects

Pocket Dosimeter
Pocket dosimeters are used to provide the wearer with an immediate reading of his or her exposure to x-rays and gamma rays. As the name implies, they are commonly worn in the pocket. The two types commonly used in industrial radiography are the Direct Read Pocket Dosimeter and the Digital Electronic Dosimeter.

Direct Read Pocket Dosimeter A direct reading pocket ionization dosimeter is generally of the size and shape of a fountain pen. The dosimeter contains a small ionization chamber with a volume of approximately two milliliters. Inside the ionization chamber is a central wire anode, and attached to this wire anode is a metal coated quartz fiber. When the anode is charged to a positive potential, the charge is distributed between the wire anode and quartz fiber. Electrostatic repulsion deflects the quartz fiber, and the greater the charge, the greater the deflection of the quartz fiber. Radiation incident on the chamber produces ionization inside the active volume of the chamber. The electrons produced by ionization are attracted to, and collected by, the positively charged central anode. This collection of electrons reduces the net positive charge and allows the quartz fiber to return in the direction of the original position. The amount of movement Biological Effects is directly proportional to the amount of ionization which occurs. Biological Factors

Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

http://www.ndt-ed.org/EducationResources/CommunityColleg...onSafety/radiation_safety_equipment/pocket_dosimeter.htm (1 of 3)21-09-2011 11:22:01

Pocket Dosimeter

Dosimeter Video Clips References Quizzes

By pointing the instrument at a light source, the position of the fiber may be observed through a system of built-in lenses. The fiber is viewed on a translucent scale which is graduated in units of exposure. Typical industrial radiography pocket dosimeters have a full scale reading of 200 milliroentgens but there are designs that will record higher amounts. During the shift, the dosimeter reading should be checked frequently. The measured exposure should be recorded at the end of each shift. The principal advantage of a pocket dosimeter is its ability to provide the wearer an immediate reading of his or her radiation exposure. It also has the advantage of being reusable. The limited range, inability to provide a permanent record, and the potential for discharging and reading loss due to dropping or bumping are a few of the main disadvantages of a pocket dosimeter. The dosimeters must be recharged and recorded at the start of each working shift. Charge leakage, or drift, can also affect the reading of a dosimeter. Leakage should be no greater than 2 percent of full scale in a 24 hour period. Digital Electronic Dosimeter Another type of pocket dosimeter is the Digital Electronic Dosimeter. These dosimeters record dose information and dose rate. These dosimeters most often use Geiger-Mller counters. The output of the radiation detector is collected and, when a predetermined exposure has been reached, the collected charge is discharged to trigger an electronic counter. The counter then displays the accumulated exposure and dose rate in digital form. Some Digital Electronic Dosimeters include an audible alarm feature which emits an audible signal or chirp with each recorded increment of exposure. Some models can also be set to provide a continuous audible signal when a preset exposure has been reached. This format helps to minimize the reading errors associated with direct reading pocket ionization chamber dosimeters and allows the instrument to achieve a higher maximum readout before resetting is necessary.

http://www.ndt-ed.org/EducationResources/CommunityColleg...onSafety/radiation_safety_equipment/pocket_dosimeter.htm (2 of 3)21-09-2011 11:22:01

Pocket Dosimeter

http://www.ndt-ed.org/EducationResources/CommunityColleg...onSafety/radiation_safety_equipment/pocket_dosimeter.htm (3 of 3)21-09-2011 11:22:01

Audible Alarm Rate Meters

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms

Audible Alarm Rate Meters and Digital Electronic Dosimeters


Audible alarms are devices that emit a short "beep" or "chirp" when a predetermined exposure has been received. It is required that these electronic devices be worn by an individual working with gamma emitters. These devices reduce the likelihood of accidental exposures in industrial radiography by alerting the radiographer to dosages of radiation above a preset amount. Typical alarm rate meters will begin sounding in areas of 450500 mR/h. It is important to note that audible alarms are not intended to be and should not be used as replacements for survey meters.

Most audible alarms use a Geiger-Mller detector. The output of the detector is collected, and when a predetermined exposure has been reached, this collected charge is discharged through a speaker. Safe Use of Radiation Hence, an audible "chirp" is emitted. Consequently, the frequency or chirp rate of the alarm is NRC & Code of Federal proportional to the radiation intensity. The chirp rate varies among different alarms from one chirp per Regs Exposure Limits milliroentgen to more than 100 chirps per milliroentgen

Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

http://www.ndt-ed.org/EducationResources/CommunityCollege...iationSafety/radiation_safety_equipment/audible_alarm.htm (1 of 2)21-09-2011 11:31:22

Audible Alarm Rate Meters

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege...iationSafety/radiation_safety_equipment/audible_alarm.htm (2 of 2)21-09-2011 11:31:22

Film Badges

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Film Badges
Personnel dosimetry film badges are commonly used to measure and record radiation exposure due to gamma rays, X-rays and beta particles. The detector is, as the name implies, a piece of radiation sensitive film. The film is packaged in a light proof, vapor proof envelope preventing light, moisture or chemical vapors from affecting the film.

A special film is used which is coated with two different emulsions. One side is coated with a large grain, fast emulsion that is sensitive to low levels of exposure. The other side of the film is coated with a fine grain, slow emulsion that is less sensitive to exposure. If the radiation exposure causes the fast emulsion in the processed film to be darkened to a degree that it cannot be interpreted, the fast emulsion is removed and the dose is computed using the slow emulsion. The film is contained inside a film holder or badge. The badge incorporates a series of filters to determine the quality of the radiation. Radiation of a given energy is attenuated to a different extent by various types of absorbers. Therefore, the same quantity of radiation incident on the badge will produce a different degree of darkening under each filter. By comparing these results, the energy of the radiation can be determined and the dose can be calculated knowing the film response for that energy. The badge holder also contains an open window to determine radiation exposure due to beta particles. Beta particles are effectively shielded by a thin amount of material.

The major advantages of a film badge as a personnel monitoring device are that it provides a permanent record, it is able to distinguish between different energies of photons, and it can measure doses due to different types of radiation. It is quite accurate for exposures greater than 100 millirem. The major disadvantages are that it must be developed and read by a processor (which is time consuming), prolonged heat exposure can affect the film, and exposures of less than 20 millirem of gamma radiation cannot be accurately measured.

http://www.ndt-ed.org/EducationResources/CommunityCollege...adiationSafety/radiation_safety_equipment/film_badges.htm (1 of 2)21-09-2011 11:32:09

Film Badges

Film badges need to be worn correctly so that the dose they receive accurately represents the dose the wearer receives. Whole body badges are worn on the body between the neck and the waist, often on the belt or a shirt pocket. The clip-on badge is worn most often when performing X-ray or gamma radiography. The film badge may also be worn when working around a low curie source. Ring badges are worn on a finger of the hand most likely to be exposed to ionizing radiation. A LIXI system with its culminated and directional beam would be one example where monitoring the hands would be more important than the whole body.

Dosimeter Video Clips References Quizzes

http://www.ndt-ed.org/EducationResources/CommunityCollege...adiationSafety/radiation_safety_equipment/film_badges.htm (2 of 2)21-09-2011 11:32:09

Thermoluminescent Dosimeter

Home - Education Resources - NDT Course Material - Radiation

Radiation Safety
Introduction Background Information X-Radiation Gamma Radiation Health Concerns Radiation Theory Nature of Radiation Sources of High Energy Rad Rad for Ind Radiography Decay and Half-life Energy, Activity, Intensity and Exposure Interaction with Matter Ionization Radiosensitivity Measures Related to Biological Effects Biological Effects Biological Factors Stochastic (Delayed) Effects -Cancer -Leukemia -Genetic Effects -Cataracts Nonstochastic (Acute) Effects Symptoms Safe Use of Radiation NRC & Code of Federal Regs Exposure Limits Controlling Exposure -Time-Dose Calculation -Distance-Intensity Calc HVL Shielding Safety Controls Responsibilities Procedures Survey Techniques Radiation Safety Equipment Radiation Detectors Survey Meters Pocket Dosimeter Audible Alarm Rate Meters Film Badges Thermoluminescent

Thermoluminescent Dosimeter
Thermoluminescent dosimeters (TLD) are often used instead of the film badge. Like a film badge, it is worn for a period of time (usually 3 months or less) and then must be processed to determine the dose received, if any. Thermoluminescent dosimeters can measure doses as low as 1 millirem, but under routine conditions their low-dose capability is approximately the same as for film badges. TLDs have a precision of approximately 15% for low doses. This precision improves to approximately 3% for high doses. The advantages of a TLD over other personnel monitors is its linearity of response to dose, its relative energy independence, and its sensitivity to low doses. It is also reusable, which is an advantage over film badges. However, no permanent record or re-readability is provided and an immediate, on the job readout is not possible. How it works A TLD is a phosphor, such as lithium fluoride (LiF) or calcium fluoride (CaF), in a solid crystal structure. When a TLD is exposed to ionizing radiation at ambient temperatures, the radiation interacts with the phosphor crystal and deposits all or part of the incident energy in that material. Some of the atoms in the material that absorb that energy become ionized, producing free electrons and areas lacking one or more electrons, called holes. Imperfections in the crystal lattice structure act as sites where free electrons can become trapped and locked into place. Heating the crystal causes the crystal lattice to vibrate, releasing the trapped electrons in the process. Released electrons return to the original ground state, releasing the captured energy from ionization as light, hence the name thermoluminescent. Released light is counted using photomultiplier tubes and the number of photons counted is proportional to the quantity of radiation striking the phosphor. Instead of reading the optical density (blackness) of a film, as is done with film badges, the amount of light released versus the heating of the individual pieces of thermoluminescent material is measured. The "glow curve" produced by this process is then related to the radiation exposure. The process can be repeated many times.