You are on page 1of 4

Efficient,

T-Series Tower Dryers


quiet,
dependable,
advanced
drying
system.

"Your Complete
Systems
Manufacturer."
1

2
Gravity inlet does not
require leveling conveyor.
Adjustable grain height
in the garner section
T-Series 1

T-Series Tower Dryers are designed with the mid-sized


provides flexibility to 2

receive grains with 3 to large farm in mind. Capacities range from 1200 BPH
different angles of to 2400 BPH. All heat from cooling grain is recycled
repose.
and the long retention times result in very efficient dryer
3 Motorized grain
level monitor
operation. A divider hopper prevents the build-up of
designed for 4 fines in the heat section, simplifying maintenance. Self
trouble free diagnostic controls accurately monitor grain moisture
positive control.
and temperature. If you need an efficient, quiet, and de-
4 Heat plenum
chamber is sur-
pendable drying system, the GSI T-Series Tower Dryer
rounded by 5
is just what you're looking for.
12-5/8" grain
columns
6
allowing grain
to see all BTU's
added to the
burner while
providing superior
noise reduction. 7
No BTU's are lost
through the duct work.
5 Uniform low velocity
heated air reduces par-
ticulate emissions.
6 Grain exchangers are
used to equalize column
moisture content and
temperature of the grain Vision Network Dryer Controls
column.
The GSI Vision Control System lets you control all dryer
7 Stainless Steel outside
functions from one location with an easy to use touch
sheets.
screen monitor. The system uses a windows ce.net
8 Divider hopper prevents
particulate build up in operating system and a 32 bit micro-processor. The
the heat plenum cham- automatic moisture control is integrated into the main
ber and simplifies 8
control of the
maintenance. dryer, and features Touch Screen
9 Heat recovered adjustable Controls
from cooling grain sample times,
and air over the 9
graphing, and
motor reduces fuel
usage up to 30%. time stamping.
10 Sealed discharge Some of the
10
section retains notable features
particulate matter. of the Vision
Controls are: no
moving parts,
master electrical
disconnect on every
dryer, low voltage control
This product is protected under one or more of the following U.S. Patents: 6233843,
6189235, 6141886, 6101742, 6098305, 6088929, 6076276, 6073367, 6073364, 5570521,
circuitry, and a remote control box
6457256, 6035544, 5860221, 5653043, 5651193, 5604996, 5566470, 5400525. with less than 5 wires.
GSI T-Series Large Burner
For 1500 BPH and larger
Tower Dryers capacities. Maxon fuel efficient,
low nox in-line burner, with
engineered profiling, provides
even continuous heat.

Small Burner
1200 BPH and smaller
capacities use a fuel efficient
in-line octagon burner to provide
even continuous heat.

Platforms
Improved inside/outside
(OSHA type) platforms,
ladders and cages are
standard and provide
access to tower dryer.

Inner Roof Hot Air Chamber


Heavy galvanized inner roof and The hot air chamber is entirely
support provides over 300 bush- surrounded by a 12-5/8" grain
els of wet holding in the garner. column. All heated air must
The garner is totally sealed to pass through the grain column
retain particulate matter. resulting in total use of heated
air. Stainless steel, smooth
sidewall construction with
.078" and .0625" perforation
Sweep Discharge diameter helps retain maximum
Field proven (patented) particulate matter.
Accu-trol Metering System
with self cleaning provides
positive grain flow from
columns.

Access Doors
& Hatches
All areas of the dryer are
accessible through doors
and floor hatches for easy
cleaning and maintenance.
GSI T-Series Specifications
MODELS T-1050 T-1260 T-1575 T-1875 T-20100 T-24100
Blower Size 43" Axial 43" Axial 8490 8542 8542 8600
Blower Rpm 1750 1750 1035 856 981 818
Blower Hp 50 60 75 75 100 100
Metering Hp 1 1 1 1 1 1
Drying Cfm 42,300 48,400 77,100 81,800 98,600 108,300
Cooling Cfm 14,500 17,500 38,550 40,900 49,300 54,150
Burner Capacity
11,100 11,100 16,654 17,669 21,298 23,393
(mBtu)
1. Dimensions exclude
Average Heat Use outside catwalk.
5,711 6,534 9,576 10,159 12,246 13,451
(mBtu)
2. Includes amperage for one
Grain Column 12-3/4” 12-3/4” 12-3/4” 12-3/4” 12-3/4” 12-3/4” 10 HP unload motor.
Tower Diameter 12’-0” 12’-0” 12’-0” 12’-0” 12’-0” 12’-0” 3. Capacities listed are wet
bushels/tonnes, shelled
Overall Height 45’-8” 52’-4" 59’-0” 69’-0” 75’-8" 85’-8”
corn at listed moisture
Wet Holding (bu) 302 302 302 302 302 302 content and are estimates
based on drying principles,
Heat Holding (bu) 610 756 914 1158 1256 1499 field results and computer
simulation. Variance
Cool Holding (bu) 219 268 305 354 451 500 may occur due to grain's
physiological factors
Dryer Holding (bu) 1232 1427 1622 1915 2110 2401 (kernel size, chemical
Outside Catwalks 0 0 1 2 2 3 composition, variety,
maturity), excessive
BPH (20% - 15%) 1000 1200 1500 1800 2000 2400 fines, adverse weather
BPH (25% - 15%) 600 720 900 1080 1200 1440 conditions, etc.

New, Mixed Flow Metering Drive Grain In-line Blower &


Industrial Blower The SCR driven variable Exchangers Divider Hopper
Highly efficient, quiet speed DC motor and the Patented grain Efficient, quiet, adjustable
industrial blower used single maintenance free exchangers equalize pitch blower delivers high
on 1500 bph and larger Cyclo gearbox located column moisture content volumes of air at low
dryers, provides years of in the free air cooling and temperature of grain horsepower on 1200 bph
trouble free operation. chamber provides column. (Standard on and smaller dryers. The
simple, trouble free T-1575 and larger dryers. surrounding divider hopper
operation of the dryers Optional on T-1050 and prevents particulate build
metering system. T-1260 dryers.) up in the heat plenum of
the dryer.
®

Grain Systems 1004 East Illinois Street · Assumption, Illinois 62510


Ph: 217-226-4421 · Fax: 800-800-5329 · Int’l Tel: 1-217-226-4401
GS-10T
Dec 07
“Your Complete Systems Manufacturer.” Int’l Fax: 1-217-226-3404 · www.gsiag.com · E-mail: gsisales@gsiag.com Copyright © 2007 GSI Group

You might also like