You are on page 1of 28

york air-conditioning products

YHK Hydro Cassette


2 & 4 pipe system
A complete range from 1.3 kW to 11.1 kW

Coloured versions available as a option

Wired controls
BR Remote three speeds controller TR BR + Electronic thermostat and Summer/Winter switch ATR Automatic TR DTR Digital Automatic Remote controller TMO 503 SV2 Digital Automatic Remote controller to be mounted in the standard light wall box DRC - DI Centralized controller up to 60 terminals

Features
Cooling duty from 1.3 to 11.1 kW YHKH: models with infrared control (standard) YHKY: models with wired control (accessory) 2 (-2) & 4 (-4) pipes systems in all range 2 sizes: 600 x 600 & 800 x 800 Possible to choice between 6 fan speeds Condensate pump integrated in all range 2/3 way valves tted or supplied loose in all range Coloured versions, possible to change the colour of the grid and the frame Possible to select a complete range of controls Electric heater tted as an option for all range (2 pipe only) All metal parts insulated to avoid condensations

Infrared control

FX03 Terminal unit controller BacNET and N2 Metasys network compatible (see page 103 for details)

02/03

1.3 to 11.1 kW

Technical features 2 pipe system


Model Cooling capacity Sensible cooling capacity Heating capacity Power supply Airow Fan Water ow Water content Pressure drop in cooling Pressure drop in heating Sound power level Sound pressure level * Dimensions (H x W x D) Panel (W x D) Packed unit net weight kW kW kW V/Ph/Hz m3/h W A l/h l kPa kPa dB(A) dB(A) mm mm kg YHK 20-2 1.3 / 1.6 / 2.0 1.0 / 1.3 / 1.6 1.6 / 2.1 / 2.6 310 / 420 / 610 25 / 32 / 57 0.11 / 0.15 / 0.27 219 / 280 / 340 0.8 4.5 / 7.0 / 10.0 4.0 / 6.0 / 9.0 33 / 40 / 49 24 / 31 / 40 YHK 25-2 1.8 / 2.3 / 2.7 1.4 / 1.8 / 2.0 2.2 / 2.9 / 3.4 YHK 40-2 2.3 / 3.3 / 4.3 1.6 / 2.4 / 3.2 2.6 / 3.9 / 5.2 YHK 50-2 2.9 / 3.9 / 5.0 2.1 / 2.8 / 3.7 3.4 / 4.6 / 6.2 230 / 1 / 50 + E 430 / 610 / 880 32 / 57 / 90 0.15 / 0.27 / 0.45 506 / 667 / 863 2.1 7.5 / 12.4 / 19.7 6.7 / 11.2 / 17.7 41 / 49 / 59 32 / 40 / 50 YHK 65-2 4.2 / 4.9 / 6.2 3.0 / 3.6 / 4.6 5.1 / 6.0 / 7.8 630 / 820 / 1140 33 / 48 / 77 0.15 / 0.23 / 0.36 724 / 845 / 1060 3.0 10.9 / 14.3 / 21.6 6.7 / 9.9 / 15.1 33 / 40 / 48 24 / 31 / 39 YHK 95-2 5.3 / 6.8 / 9.5 3.5 / 4.5 / 6.5 5.6 / 7.3 / 10.7 YHK 110-2 5.3 / 8.5 / 11.1 3.7 / 6.1 / 8.3 6.1 / 10.3 / 14.0

28

310 / 420 / 520 320 / 500 / 710 25 / 32 / 44 25 / 44 / 68 0.11 / 0.15 / 0.20 0.11 / 0.20 / 0.32 316 / 402 / 461 387 / 574 / 745 1.4 2.1 4.9 / 7.6 / 9.7 4.6 / 9.4 / 15.1 4.1 / 6.3 / 8.2 3.5 / 7.3 / 11.4 33 / 40 / 45 33 / 45 / 53 24 / 31 / 36 24 / 36 / 44 275 x 575 x 575 670 x 670 28 30

30
3

44

710 / 970 / 1500 710 / 1280 / 1820 42 / 63 / 120 42 / 95 / 170 0.18 / 0.28 / 0.53 0.18 / 0.42 / 0.74 913 / 1166 / 1636 913 / 1453 / 1909 4.0 4.0 9.4 / 14.7 / 26.9 9.4 / 21.8 / 35.6 7.9 / 12.4 / 23.0 7.9 / 18.6 / 30.6 34 / 40 / 53 34 / 48 / 58 25 / 31 / 44 25 / 39 / 49 303 x 820 x 820 965 x 965 47 47

* The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m Cooling capacities based on 7/12C EWT - Indoor temperature 27C DB / 19C WB Heating capacities based on 50C EWT at nominal ow rate Indoor temperature 20C Water ow rate as for the cooling conditions. All data are in equivalent to Low / Medium / High speed.

room and a reverberation time of 0.5 sec.

Technical features 4 pipe system


Model Cooling capacity Sensible cooling capacity Heating capacity Power supply Airow Fan Water ow in cooling Water ow in heating Water content Cooling / Heating Pressure drop in cooling Pressure drop in heating Sound power level Sound pressure level * Dimensions (H x W x D) Panel (W x D) Packed unit net weight kW kW kW V/Ph/Hz m3/h W A l/h l/h l kPa kPa dB(A) dB(A) mm mm kg YHK 50-4 YHK 65-4 2.4 / 3.0 / 3.8 4.1 / 5.0 / 6.3 1.8 / 2.3 / 3.0 3.0 / 3.7 / 4.7 3.1 / 4.0 / 5.0 5.9 / 7.2 / 9.1 230 / 1 / 50 + E 310 / 420 / 610 310 / 420 / 520 320 / 500 / 710 430 / 610 / 880 630 / 820 / 1140 25 / 32 / 57 25 / 32 / 44 25 / 44 / 68 32 / 57 / 90 33 / 48 / 77 0.11 / 0.15 / 0.27 0.11 / 0.15 / 0.20 0.11 / 0.20 / 0.32 0.15 / 0.27 / 0.45 0.15 / 0.23 / 0.36 260 / 337 / 401 318 / 406 / 464 318 / 456 / 574 406 / 519 / 655 712 / 865 / 1090 169 / 219 / 261 209 / 260 / 298 209 / 298 / 378 267 / 341 / 426 508 / 618 / 783 1 / 0.6 1.4 / 0.7 1.4 / 0.7 1.4 / 0.7 3.0 / 1.4 6.0 / 10.0 / 13.5 4.6 / 6.9 / 8.8 4.6 / 8.8 / 13.4 7.2 / 11.2 / 17.0 8.8 / 12.5 / 18.9 6.5 / 10.5 / 14.5 5.7 / 8.5 / 10.8 5.7 / 10.8 / 16.6 8.8 / 13.8 / 20.5 9.8 / 14.0 / 21.4 33 / 40 / 49 33 / 40 / 45 33 / 45 / 53 41 / 49 / 59 33 / 40 / 48 24 / 31 / 40 24 / 31 / 36 24 / 36 / 44 32 / 40 / 50 24 / 31 / 39 275 x 575 x 575 670 x 670 30 30 30 30 47
3

YHK 20-4 1.5 / 2.0 / 2.3 1.2 / 1.6 / 1.9 2.0 / 2.5 / 3.0

YHK 25-4 1.9 / 2.4 / 2.7 1.4 / 1.7 / 2.0 2.4 / 3.0 / 3.5

YHK 40-4 1.9 / 2.7 / 3.3 1.3 / 2.0 / 2.6 2.4 / 3.5 / 4.4

YHK 95-4 4.5 / 5.7 / 7.7 3.3 / 4.2 / 5.8 6.5 / 8.1 / 11.0 710 / 970 / 1500 42 / 63 / 120 0.18 / 0.28 / 0.53 777 / 974 / 1326 555 / 697 / 946 3.0 / 1.4 10.3 / 15.4 / 26.9 11.5 / 17.4 / 29.9 34 / 40 / 53 25 / 31 / 44 303 x 820 x 820 965 x 965 47

YHK 110-4 4.5 / 6.9 / 8.9 3.3 / 5.2 / 6.8 6.5 / 10.0 / 12.7 710 / 1280 / 1820 42 / 95 / 170 0.18 / 0.42 / 0.74 777 / 1192 / 1529 555 / 858 / 1092 3.0 / 1.4 10.3 / 22.1 / 34.7 11.5 / 25.3 / 38.8 34 / 48 / 58 25 / 39 / 49

47

* The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m Cooling capacities based on 7/12C EWT - Indoor temperature 27C DB / 19C WB Heating capacities based on 70/60C EWT - Indoor temperature 20C All data are in equivalent to Low / Medium / High speed.

room and a reverberation time of 0.5 sec.

Condensate pump integrated in all sizes

Metal parts insulated to avoid condensation

2 or 3 way valves tted or supplied loose in all sizes

Outer casing as an option to integrate the water cassette into any enviroment

E-COM-H1101

Manufacturer reserves the rights to change specications without prior notice.

Water Systems

YHK Hydro Cassette

york air-conditioning products

YHK ECM Inverter Hydro Cassette


2 & 4 pipe system
A complete range from 1.8 kW to 10.8 kW

Coloured versions available as a option

Wired control
ETN-ECM Wall-mounted controller that can be connected that allows the inverter control with a 0-10V signal. The same controller can be connected to one or several cassettes (master-slave function).

Features
Cooling duty from 1.8 to 10.8 kW YHKH: models with infrared control (standard) YHKY: models with wired control (accessory) 2 (-2) & 4 (-4 or -6) pipes systems 2 sizes: 600 x 600 & 800 x 800 Condensate pump integrated in all range 2/3 way valves tted or supplied loose in all range Coloured versions, possible to change the colour of the grid and the frame All metal parts insulated to avoid condensations Inverter fan motor for a very quiet operation Electrical consumption reduced by up to 75% Specic range of controllers with master-slave function

Infrared control

FX03 Terminal unit controller BacNET and N2 Metasys network compatible (see page 103 for details)

04/05

1.8 to 10.8 kW

Technical features 2 pipe system


Model Cooling capacity Sensible cooling capacity Heating capacity Power supply Airow Fan Water ow Water content Pressure drop in cooling Pressure drop in heating Sound power level Sound pressure level * Dimensions (H x W x D) Panel (W x D) Packed unit net weight kW kW kW V/Ph/Hz m3/h W l/h l kPa kPa dB(A) dB(A) mm mm kg YHK-ECM 25-2 1.8 / 2.2 / 2.8 1.4 / 1.6 / 2.1 2.2 / 2.7 / 3.4 310 / 380 / 535 5 / 8 / 16 317 / 373 / 473 1.4 4.9 / 6.6 / 10.1 4.0 / 5.5 / 8.7 33 / 39 / 47 24 / 30 / 38 YHK-ECM 40-2 2.2 / 3.1 / 4.3 1.6 / 2.2 / 3.2 2.6 / 3.6 / 5.2 310 / 445 / 710 5 / 11 / 31 385 / 524 / 744 2.1 4.6 / 9.4 / 15.1 3.6 / 6.6 / 13.1 33 / 43 / 54 24 / 34 / 45 275 x 575 x 575 670 x 670 30 YHK-ECM 50-2 2.6 / 3.9 / 5.0 1.8 / 2.8 / 3.7 3.0 / 4.6 / 6.2 230 / 1 / 50 + E 360 / 610 / 880 7 / 21 / 62 441 / 666 / 864 2.1 5.9 / 12.4 / 19.7 4.7 / 10.5 / 17.7 37 / 50 / 60 28 / 41 / 51 YHK-ECM 65-2 4.2 / 5.2 / 6.3 3.0 / 3.8 / 4.7 5.1 / 6.4 / 8.0 YHK-ECM 95-2 5.3 / 7.7 / 10.8 3.7 / 5.5 / 7.9 5.9 / 8.8 / 12.7

28

30
3

630 / 870 / 1165 710 / 1130 / 1770 10 / 17 / 33 10 / 32 / 108 723 / 885 / 1089 909 / 1328 / 1848 3.0 4.0 10.9 / 15.6 / 22.7 9.4 / 18.5 / 33.6 8.7 / 12.8 / 19.5 7.2 / 14.9 / 28.8 33 / 39 / 48 34 / 47 / 57 24 / 30 / 39 25 / 38 / 48 303 x 820 x 820 965 x 965 44 47 room and a reverberation time of 0.5 sec.

* The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m Cooling capacities based on 7/12C EWT - Indoor temperature 27C DB / 19C WB Heating capacities based on 50C EWT at nominal ow rate Indoor temperature 20C Water ow rate as for the cooling conditions. All data are in equivalent to Low / Medium / High speed.

Technical features 4 pipe system


Model Cooling capacity Sensible cooling capacity Heating capacity Power supply Airow Fan Water ow in cooling Water ow in heating Water content Cooling / Heating Pressure drop in cooling Pressure drop in heating Sound power level Sound pressure level * Dimensions (H x W x D) Panel (W x D) Packed unit net weight kW kW kW V/Ph/Hz m3/h W l/h l/h l kPa kPa dB(A) dB(A) mm mm kg YHK-ECM 25-4 1.9 / 2.2 / 2.8 1.3 / 1.6 / 2.1 2.4 / 2.9 / 3.6 310 / 380 / 535 5 / 8 / 16 318 / 375 / 476 209 / 245 / 311 1.4 / 0.7 4.6 / 6.2 / 9.5 5.7 / 7.6 / 11.7 33 / 39 / 47 24 / 30 / 38 YHK-ECM 40-6 2.1 / 2.8 / 3.9 1.5 / 2.0 / 3.0 2.0 / 2.5 / 3.4 310 / 445 / 710 5 / 11 / 31 359 / 483 / 676 170 / 217 / 288 1.7 / 0.5 3.5 / 5.7 / 10.5 3.5 / 5.5 / 9.0 33 / 43 / 54 24 / 34 / 45 275 x 575 x 575 670 x 670 30 YHK-ECM 50-6 2.4 / 3.5 / 4.5 1.7 / 2.6 / 3.5 2.2 / 3.1 / 3.8 230 / 1 / 50 + E 360 / 610 / 880 7 / 21 / 62 409 / 608 / 779 189 / 263 / 326 1.7 / 0.5 4.1 / 8.4 / 13.1 4.5 / 7.5 / 11.0 37 / 50 / 60 28 / 41 / 51 YHK-ECM 65-4 4.3 / 5.3 / 6.5 3.1 / 3.8 / 4.8 6.1 / 7.5 / 9.4 YHK-ECM 95-6 5.0 / 7.2 / 9.9 3.5 / 5.2 / 7.4 5.2 / 7.2 / 9.5

30

30
3

630 / 870 / 1165 710 / 1130 / 1770 10 / 17 / 33 10 / 32 / 108 740 / 908 / 1120 856 / 1233 / 1697 528 / 649 / 805 449 / 616 / 818 3.0 / 1.4 3.6 / 1.1 9.4 / 13.6 / 19.8 8.8 / 17.0 / 30.1 10.5 / 15.5 / 22.5 6.5 / 11.0 / 18.0 33 / 39 / 48 34 / 47 / 57 24 / 30 / 39 25 / 38 / 48 303 x 820 x 820 965 x 965 47 47 room and a reverberation time of 0.5 sec.

* The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m Cooling capacities based on 7/12C EWT - Indoor temperature 27C DB / 19C WB Heating capacities based on 70/60C EWT - Indoor temperature 20C All data are in equivalent to Low / Medium / High speed.

Condensate pump integrated in all sizes

Metal parts insulated to avoid condensation

2 or 3 way valves tted or supplied loose in all sizes

Outer casing as an option to integrate the water cassette into any enviroment

E-COM-H1102

Manufacturer reserves the rights to change specications without prior notice.

Water Systems

YHK ECM Inverter Hydro Cassette

york air-conditioning products

Options & Accessories


Compatibility table / Codes
Model (Panel not included) Cassette YHKY Cassette YHKH - with infrared remote control included Cassette YHKY-ECM - basic model Cassette YHKH-ECM - basic model Options (Factory tted) Cassette YHKY-E - with electric resistance Version without infrared remote control YHKY-E Version with infrared remote control included YHKH-E Cassette YHKY-REB - with remote electric board Cassette YHKY-REB Valves 3 way valve + mounting kit for 2 pipe models (factory tted) 3 way valve + mounting kit for 4 pipe models (factory tted) Accessories (supplied loose) Air di users / Panels Air di user - intake grid, frame and louvres in RAL 9003 white colour Air di user - other colours (*) Valves (220V On/O ) 3 way valve + mounting kit for 2 pipe models (not tted) 3 way valve + mounting kit for 4 pipe models (not tted) 2 way valve + mounting kit for 2 pipe models (not tted) 2 way valve + mounting kit for 4 pipe models (not tted) 3 way valve + mounting kit for units with outer casing OCA (not tted) 3 way valve + mounting kit for units with outer casing OCA (not tted) Other type of valves Other valves Other Accessories Outer casing AKPA 600 AKPA 800

2 pipe system 4 pipe system 2 pipe system 4 pipe system 2 pipe system 4 pipe system 2 pipe system 4 pipe system

YHK 20 0079100K 0079110K 0079140K 0079150K


-

YHK 25 0079000K 0079010K 0079040K 0079050K 0079801K 0079811K 0079821K 0079831K

YHK 40 0079001K 0079011K 0079041K 0079051K 0079802K 0079812K 0079822K 0079832K

YHK 50 0079002K 0079012K 0079042K 0079052K 0079803K 0079813K 0079823K 0079833K

YHK 65 0079003K 0079013K 0079043K 0079053K 0079804K 0079814K 0079824K 0079834K

YHK 95 0079004K 0079014K 0079044K 0079054K 0079805K 0079815K 0079825K 0079835K

YHK 110 0079005K 0079015K 0079045K 0079055K


-

2 pipe system 2 pipe system 2 pipe system 4 pipe system 9079510 9079511 9079512 9079513

0079060K 0079080K 0079020K 0079030K


-

0079061K 0079081K 0079021K 0079031K

0079062K 0079082K 0079022K 0079032K

0079063K 0079083K 0079023K 0079033K

0079064K 0079084K 0079024K 0079034K


0079065K 0079085K 0079025K 0079035K

0079120K 0079130K

Contact Johnson Controls 9079500 9079501 9079502 9079503 9079505 9079506 9079507 9079508 9079155 9079156

Contact Johnson Controls OCA 600 OCA 800 FAD FAK 600 FAK 800

Fresh air duct Fresh air kit 1 way for units with outer casing OCA Fresh air kit 1 way for units with outer casing OCA CONTROLS for YHKY versions Remote three speed control BR 9060540 Remote three speed control + electronic thermostat and 9060541 S/W switch TR Automatic speed control with electronic thermostat and 9060542 S/W - ATR Automatic speed control with electronic thermostat to be 9060172 mounted in the light wall box TMO-503-SV2 Receiver REC-S 9079110 Automatic remote control with electronic thermostat, 9060521 S/W swithc and liquid crystall display DTR Receiver (slave) for control DTR RECD 9060139 Change over CH 15-25 9053049 Low temperature cut out thermostat TME 3021091 CONTROLS for YHKH versions Digital remote control up to 60 multifunction units DRC-DI 9079102 Change over for infrared remote control CH T2 9079103 CONTROLS only for YHK-ECM version Digital remote control up to 60 multifunction units DRC-DI 9079102 ETM-ECM control 3021232 RT03/ECM infrared remote control 9079220 Maxinet management system for a network of cassette fan coil Maxinet 9079104 Board 8 relais for Maxinet 9079105 (*) Minimum order quantity : 20 units

06/07

YHK 20/25/40/50-2 / YHK 20/25/40/50-4. (Version 600x600) YHK-ECM 25/40/50-2 / YHK-ECM 25-4 / 40/50-6. (Version 600x600)

All dimensions in mm. Drawings not a scale.

YHK 65/95/110-2 / YHK 65/95/110-4. (Version 800x800) YHK-ECM 65/95-2 / YHK-ECM 65-4 / 95-6. (Version 800x800)

All dimensions in mm. Drawings not a scale.

Water Systems

Dimensions

york air-conditioning products

YFCC Coanda Hydro Cassette


2 & 4 pipe system
A complete range from 0.9 kW to 4.0 kW

NEW

Wired controls
BR Remote three speeds controller TR BR + Electronic thermostat and Summer/Winter switch ATR Automatic TR DTR Digital Automatic Remote controller TMO 503 SV2 Digital Automatic Remote controller to be mounted in the standard light wall box DRC - DI Centralized controller up to 60 terminals

Features
Coanda e ect units, allowing easier and cheaper installation Cooling duty from 0.9 to 4.0 kW 2 & 4 (+1 or +2) pipes systems in all range 3 sizes: 600 x 600, 600 x 1000 & 600 x 1200 2/3 way valves tted or supplied loose in all range Left and right hand (optional) water connections 6 fan speeds (3 pre-wired) Air throw till 7.6m (cooling) and 9.5m (heating)

Infrared control

ect

08/09

0.9 to 4.0 kW

Technical features 2 pipe system


Model Cooling capacity Sensible cooling capacity Heating capacity Power supply Airow Fan Pressure drop in cooling Pressure drop in heating Sound power level Sound pressure level * Dimensions (H x W x D) Net weight kW kW kW V/Ph/Hz m3/h W kPa kPa dB(A) dB(A) mm kg YFCC 130 0.9 / 1.1 / 1.5 0.7 / 0.8 / 1.2 1.1 / 1.3 / 1.9 YFCC 140 1.0 / 1.2 / 1.7 0.7 / 0.9 / 1.3 1.1 / 1.4 / 2.1 YFCC 230 YFCC 240 1.4 / 1.6 / 2.4 1.4 / 1.7 / 2.6 1.0 / 1.2 / 1.8 1.0 / 1.2 / 1.9 1.6 / 1.9 / 2.9 1.7 / 2.0 / 3.1 230 / 1 / 50 + E 200 / 240 / 380 200 / 240 / 380 24 / 27 / 44 24 / 27 / 44 2.9 / 3.9 / 7.6 4.4 / 6.0 / 12.1 2.3 / 3.1 / 6.3 3.5 / 4.8 / 10.2 33 / 36 / 48 33 / 36 / 48 24 / 27 / 39 24 / 27 / 39 309 x 592 x 970 33 35
3

YFCC 330 2.0 / 2.8 / 3.3 1.4 / 2.1 / 2.5 2.3 / 3.4 / 4.0

YFCC 340 2.5 / 3.6 / 4.0 1.8 / 2.6 / 3.0 2.9 / 4.2 / 4.8

140 / 180 / 280 140 / 180 / 280 16 / 22 / 49 16 / 22 / 49 2.4 / 3.3 / 6.1 4.7 / 6.7 / 12.9 1.8 / 2.6 / 4.9 3.7 / 5.4 / 10.7 35 / 41 / 52 35 / 41 / 52 26 / 32 / 43 26 / 32 / 43 309 x 592 x 592 16 18

290 / 440 / 540 360 / 540 / 620 27 / 42 / 59 33 / 59 / 72 6.4 / 12.1 / 16.2 6.7 / 12.6 / 15.5 5.2 / 9.8 / 13.4 5.5 / 10.0 / 12.6 35 / 46 / 52 41 / 52 / 55 26 / 37 / 43 32 / 43 / 46 309 x 592 x 1192 42 45

* The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m Cooling capacities based on 7/12C EWT - Indoor temperature 27C DB / 19C WB Heating capacities based on 50C EWT at nominal ow rate Indoor temperature 20C Water ow rate as for the cooling conditions All data are in Low / Medium / High speeds pre-wired

room and a reverberation time of 0.5 sec.

Technical features 4 pipe system


Model Cooling capacity Sensible cooling capacity Heating capacity Power supply Airow Fan Pressure drop in cooling Pressure drop in heating Sound power level Sound pressure level * Dimensions (H x W x D) Net weight kW kW kW V/Ph/Hz m3/h W kPa kPa dB(A) dB(A) mm kg YFCC 130+1 0.9 / 1.1 / 1.5 0.7 / 0.8 / 1.2 0.9 / 1.1 / 1.5 140 / 180 / 280 16 / 22 / 49 2.4 / 3.3 / 6.1 1.6 / 2.1 / 3.6 35 / 41 / 52 26 / 32 / 43 309 x 592 x 592 19 YFCC 230+1 1.4 / 1.6 / 2.4 1.0 / 1.2 / 1.8 1.5 / 1.7 / 2.4 230 / 1 / 50 + E 200 / 240 / 380 24 / 27 / 44 2.9 / 3.9 / 7.6 0.9 / 1.2 / 2.0 33 / 36 / 48 24 / 27 / 39 309 x 592 x 970 38
3

YFCC 330+1 2.0 / 2.8 / 3.3 1.4 / 2.1 / 2.5 2.1 / 2.9 / 3.3 290 / 440 / 540 27 / 42 / 59 6.4 / 12.1 / 16.2 2.0 / 3.4 / 4.3 35 / 46 / 52 26 / 37 / 43 309 x 592 x 1192 48 room and a reverberation time of 0.5 sec.

* The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m Cooling capacities based on 7/12C EWT - Indoor temperature 27C DB / 19C WB Heating capacities based on 70/60C EWT - Indoor temperature 20C All data are in Low / Medium / High speeds pre-wired

Round di user The YFCC one-way cassette units are supplied with round di users suitably designed to generate an airow with coanda e ect. The direction of di user air ow can be adjusted on site.

E-COM-H1103

Manufacturer reserves the rights to change specications without prior notice.

Water Systems

YFCC Coanda Hydro Cassette

york air-conditioning products

Options & Accessories


Compatibility table / Codes
Model (Panel not included) 2 pipe system Cassette YFCC Options (Factory tted) Right hand connection Valves (220V On/O ) (factory tted) 3 way valve + mounting kit for 2 pipe models (factory tted) 3 way valve + additional battery (factory tted) 2 way valve + additional battery (factory tted) Controls Infrared control Accessories (supplied loose) Valves (220V On/O ) 3 way valve + mounting kit for 4 pipe models (not tted) 3 way valve + additional battery not tted 2 way valve + additional battery not tted Other type of valves Other valves Wired controls Remote three speed control BR Remote three speed control + electronic thermostat and S/W switch TR Automatic speed control with electronic thermostat and S/W - ATR Automatic remote control with electronic thermostat, S/W swithc and liquid crystall display DTR Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-S Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-SV2 Remote thermostat with S/W switch (for 2 pipe system only) Receiver REC-S Receiver (slave) for control DTR RECD Low temperature cut out thermostat TME Low temperature cut out thermostat TMM Change over CH 15-25 Infrared and Free controls Infrared remote control with not tted electronic board for versions CD only IRC-S IRC-S control (not tted on the unit) with ETN +/-3% Low temperature cut out CH Digital remote control up to 60 multifunction units Maxinet Board 8 relais for Maxinet Remote control FREE-COM Free control Not mounted Electronic board FREE-UPS Temperature sensor FREE-SEN Low temperature cut out FREE-NTC 9060176 9060167 9079103 9079102 9079104 9079105 9060572 9060571 9060570 9060573 3021090

YFCC 130 0064001K 0064021K 0064041K 4 pipe system (+1) 4 pipe system (+2)

YFCC 140 0064011K 0064031K


-

YFCC 230 0064002K 0064022K 0064042K

YFCC 240 0064012K 0064032K


-

YFCC 330 0064003K 0064023K 0064043K

YFCC 340 0064013K 0064033K


-

Contact Johnson Controls 9066561 9060471 9060472 9060476

Contact Johnson Controls

9060175 9060166

9066560 9060474 9060475 9060478 9060479

Contact Johnson Controls Contact Johnson Controls

Contact Johnson Controls

9060540 9060541 9060542 9060521 9060170 9060172 9060174 9079110 9060139 3021091 9053048 9053049

10/11

Di ussers
A
A
A

All dimensions in mm. Drawings not a scale.

YFCC 130 to 340


298 E 309

592

E 72 F F 100 592

592

All dimensions in mm. Drawings not a scale.

Model A E F

130 / 140 592 454 78

230 / 240 970 884 43

592

330 / 340 1 192 1 099 46.5

Air Throw
C1 - Heating C2 - Cooling

L
YFCC 1 3 4 5.8 6.3 4.6 5 YFCC 2 3 4 6.1 7 4.8 5.6

L
YFCC 3 3 4 6.3 7.5 5 6

Model Air throw L (m) C1 C2

1 3.8 3

2 4.5 3.6

5 6.8 5.4

6 7.2 5.7

1 4 3.2

2 5 4

5 8 6.4

6 9 7.2

1 4.5 3.6

2 5.2 4.1

5 8.8 7

6 9.5 7.6

Water Systems

Dimensions

york air-conditioning products

YHM Hydro High Wall


2 pipe system
A range from 1.7 to 4.7 kW

NEW

Features
Wired control or infrared control Automatic air sweep 3 way valves tted (YHMH 20V and 30V models) or 2 way valves supplied loose in all range Condensate collection tray Air lter included Heat exchange coil

Wired control (YHMY)


4 operation modes (Cool/Heat/Auto/Fan) Room temperature and setting Fan speed selector (Auto, low, medium and high)

TR. Wired Control Remote three speeds controller, electronic thermostat and Summer/Winter switch ATR. Wired Control Automatic TR

Electronic Infrared Control

2 Way Valve ON/OFF with thermoelectric actuator. Suitable for the connection with 12 mm pipes

Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep Mode Room Temperature setting Fan speed selection Timer Air ow direction setting LCD display

Infrared control (YHMH)

FX03 Terminal unit controller BacNET and N2 Metasys network compatible (see page 103 for details)

Rear Frame for installation of valves (accessorie)

12/13

1.7 to 4.7 kW

Technical features
Model Cooling capacity Sensible capacity Heating capacity Air ow Electrical data Power supply Power input Noise level Sound pressure level at 1 m Dimensions and weight Height Width Depth Weight mm mm mm kg 270 845 180 10 270 845 180 10 298 920 200 13 298 920 200 13 dB(A) 36 / 33 / 29 43 / 33 / 30 46 / 43 / 39 51 / 47 / 44 V/Ph/Hz W 230 / 1 / 50 + E 24 28 40 50 kW kW kW m3/h YHMY(H) 20 2.2 / 1.9 / 1.7 1.8 / 1.6 / 1.5 2.7 / 2.3 / 2.0 436 / 376 / 334 YHMY(H) 30 2.8 / 2.0 / 1.8 2.5 / 1.8 / 1.6 3.6 / 2.6 / 2.2 632 / 522 / 403 YHMY(H) 40 4.0 / 3.4 / 3.1 3.4 / 2.9 / 2.6 4.9 / 4.2 / 3.8 780 / 691 / 570 YHMY(H) 50 4.7 / 3.9 / 3.4 3.6 / 3.3 / 2.9 5.8 / 4.9 / 4.2 920 / 810 / 697

Technical features with valve tted


Model Cooling capacity Sensible capacity Heating capacity Air ow Electrical data Power supply Power input Noise level Sound pressure level at 1 m Dimensions and weight Height Width Depth Weight mm mm mm kg 270 845 180 11 298 920 200 13 dB(A) 44 / 38 / 32 50 / 43 / 38 V/Ph/Hz W 230 / 1 / 50 + E 50 60 kW kW kW m3/h YHMH 20 V 1.7 / 1.6 / 1.2 1.3 / 1.1 / 0.9 2.4 / 2.0 / 1.7 450 / 383 / 323 YHMH 30 V 3.2 / 2.8 / 2.4 2.4 / 2.1 / 1.8 4.5 / 3.9 / 3.4 650 / 560 / 490

All data are in high/medium/low speed Cooling capacities based on 7C EWT t 5C Indoor temperature 27C DB / 19C WB Heating capacities based on 50C EWT at nominal ow rate Indoor temperature 20C Water ow rate as for the cooling conditions

Codes
Unit without infrared remote control Unit codes Unit with infrared remote control Unit codes Unit with infrared remote control and tted valve Unit codes Options (Factory tted) / Accessories (supplied loose) TR (Wired ON/OFF 3 Speeds Cool/Heat) ATR (TR + Auto speed control) 2 Way valve Rear frame Rear frame with 3 way valve Low temperature cut out Change over 9060541 9060542 9024000

YHMY 20 0024231K YHMH 20 0024241K YHMH 20 V 0024252K

YHMY 30 0024232K YHMH 30 0024242K YHMH 30 V 0024254K

YHMY 40 0024233K YHMH 40 0024243K -

YHMY 50 0024234K YHMH 50 0024244K -

9024021 9024031 3021091 9053049


9024023 9024033

E-COM-H1104

Manufacturer reserves the rights to change specications without prior notice.

Water Systems

YHM Hydro High Wall

york air-conditioning products

YFCN Fan Coil Unit centrifugal fan


2 & 4 pipe system
A complete range from 1.0 kW to 7.6 kW

Wired controls
BR Remote three speeds controller TR BR + Electronic thermostat and Summer/Winter switch ATR Automatic TR DTR Digital Automatic Remote controller TMO 503 SV2 Digital Automatic Remote controller to be mounted in the standard light wall box DRC - DI Centralized controller up to 60 terminals

Features
New Casing, improved aesthetics and suitable for any modern indoor ambient Full range for all your needs: 9 sizes suitable for horizontal/vertical mounting Models with or without casing Low noise operation 3 fan speeds (possible to choice between 6 fan speeds) Single piece discharge grid Several coil choices: Single: 3 or 4 rows, Dual: 3 rows cooling & 2 rows heating Electrical heater optional Suction and discharge plenum optional Factory tted valves and controller packages Painted back panel option 4 available versions in all range: VC = Vertical Discharge with Casing VCB = Vertical Discharge with Casing (oor installation) HC = Horizontal Discharge with Casing CD = Concealed unit without Casing

Infrared control

FX03 Terminal unit controller BacNET and N2 Metasys network compatible (see page 103 for details)

14/15

1.0 to 7.6 kW

YFCN - Technical features 2 pipes


YFCN model 130 230 330 430 530 630 730 830 930 140 240 340 440 540 640 740 840 940 Air ow m3/h 220 295 385 485 650 760 925 1 200 1 500 220 295 385 485 545 760 925 1 200 1 500 Total capacity Cooling kW 1.0 1.6 2.4 2.9 3.2 4.1 5.1 5.8 6.7 1.2 1.8 2.6 3.1 3.5 4.8 5.6 6.5 7.6 Heating kW 1.4 2.0 2.9 3.6 3.9 5.1 6.3 7.7 9.1 1.6 2.2 3.1 3.8 4.2 5.9 6.7 8.4 10.1 Pressure drop Cooling kPa 2.3 6.5 19.7 27.2 12.7 19.8 34.2 19.0 24.6 5.6 13.9 11.5 15.5 24.2 36.2 27.7 17.5 23.2 Heating kPa 2.0 5.5 16.7 23.1 10.8 16.8 29.1 16.2 20.9 4.7 11.6 9.2 12.2 19.9 29.3 23.7 14.5 19.3 Power input W 33 32 41 44 46 78 103 130 176 33 32 41 44 46 78 103 130 176 Pressure level dBA 36 38 40 38 34 43 47 51 55 36 38 40 38 34 43 47 51 55 Dimensions (with casing) Height mm 530 530 530 530 530 530 530 530 530 530 530 530 530 530 530 530 530 530 Width mm 670 770 985 985 1 200 1 200 1 415 1 415 1 415 670 770 985 985 1 200 1 200 1 415 1 415 1 415 Depth mm 225 225 225 225 225 225 225 255 255 225 225 225 225 225 225 225 255 255

With fan running at max. speed. Data for the casing models. The capacities are accordingly to the EUROVENT standards and UNI ENV 1397. COOLING: Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C HEATING: Room temperature 20C - Water inlet temperature: 50C and water ow rate is for a cooling conditions 3 room and a reverberation time of 0.5 sec. * The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m

YFCN - Technical features 4 pipes


YFCN model 130-1 230-1 330-1 430-1 530-1 630-1 730-1 830-1 930-1 Air ow m3/h 220 295 385 485 545 760 925 1 200 1 500 Total capacity Cooling kW 1.0 1.6 2.4 2.9 3.2 4.1 5.1 5.8 6.7 Heating kW 1.0 1.5 2.3 2.7 3.0 3.8 4.8 5.4 6.2 Pressure drop Cooling kPa 2.3 6.5 19.7 27.2 12.7 19.8 34.2 19.0 24.6 Heating kPa 1.7 4.0 9.7 12.8 3.2 6.7 8.3 10.3 13.2 Power input W 33 32 41 44 46 78 103 130 176 Pressure level dBA 36 38 40 38 34 43 47 51 55 Dimensions (with casing) Height mm 530 530 530 530 530 530 530 530 530 Width mm 670 770 985 985 1 200 1 200 1 415 1 415 1 415 Depth mm 225 225 225 225 225 225 225 255 255

With fan running at max. speed. Data for the casing models. The capacities are accordingly to the EUROVENT standards and UNI ENV 1397. COOLING: Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C HEATING: Room temperature 20C - Water inlet temperature: 70/60C 3 room and a reverberation time of 0.5 sec. * The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant eld of a 100 m

E-COM-H1105

Manufacturer reserves the rights to change specications without prior notice.

Water Systems

YFCN Fan Coil Unit centrifugal fan

york air-conditioning products

Options / Accessories
Compatibility table / Codes
Model Versions Three speed control BL * Three speed control + electronic thermostat and S/W switch TMV-S Three speed control + electronic thermostat and centralized S/W - TLC ** Automatic speed control with electronic thermostat and S/W switch ATL ** Infra-red remote control with tted electronic board for versions VC and HC only IRC-M ** IRC-M control (tted on the unit) with ETN +/- 3% Controls for style HC/CD (supplied with separate packaging) Remote three speed control BR * Remote three speed control + electronic thermostat and S/W switch TR *** Automatic speed control with electronic thermostat and centralized S/W - ATR *** Automatic remote controol with electronic thermostat, S/W swithc and liquid crystall display DTR ** Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-S **** Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-SV **** Infra-red remote control with NOT tted electronic board for version CD only IRC-S ** IRC-S control (not tted on the unit) with ETN +/- 3% Controls for all versions (supplied with separate packaging) Low temperature cut out TME for controls TL, TLC, ATL, ATLC, TR, DTR Low temperature cut out TMM for controls BL, BR Change over 15-25 CH 15-25 Receiving speed selector for centralized control (slave) style VC RECV Receiving speed selectror for centralized control (slave) style HC/CD RECH Receiver (slave) for control DTR RECD Digital remote control up to 60 multifunction units Three speed control BL-E * Three speed control + electronic thermostat and S/W switch BTL-E * Three speed control + electronic thermostat and S/W switch TL-E ** Three speed control + electronic thermostat and centralized S/W - TLC-E ** Automatic speed control with electronic thermostat and S/W switch ATL-E ** Automatic speed control with electronic thermostat and centralized S/W - ATLC-E ** Remote three speed control BR-E * Remote three speed control + electronic thermostat and S/W switch TR-E *** Automatic speed control with electronic thermostat and centralized S/W - ATR-E *** Automatic remote control with electronic thermostat, S/W switch and liquid crystall display DTR ** 3021091 9053048 9053049 9060136 9060137 9060139 9079102 9063000 9063001 9063002 9063003 9063004 9063005 3021091 9053048 9053049 9060136 9060137 9060139 9079102 3021091 9053048 9053049 9060136 9060137 9060139 9079102 9060540 9060541 9060542 9060521 9060170 9060172 9060167 9060540 9060541 9060542 9060521 9060170 9060172 9060176 9060167 VC/VCB mod. - Vertical with casing 9060130 9060140 9060133 9060134 9060175 9060166 Controls for style VC (supplied with separate packaging) 9060175 9060166 9060166 YFCN HC mod. - Horizontal with casing CD mod. - Without casing

Controls for style VC + additional electric resistance (supplied with separate packaging)

Controls for style HC/CD + additional electric resistance (supplied with separate packaging) 9063050 9063051 9063024 9060521 9063050 9063051 9063024 9060521

* not to be used with valves and/or low temperature cut-out ** it can be used with valves and/or low temperature cut-out *** to be used with valves and/or low temperature cut-out. The Winter/Summer switch is manual/centralized in accordance to the position of the J1 Jumper **** low temperature cut-out included

16/17

Compatibility table / Codes


Model Sizes Valves Kit 3 way valve mounted Kit 3 way valve additional battery mounted Kit 3 way valve not mounted Kit 3 way valve additional battery not mounted Kit 2 way valve primary + additional battery mounted Kit 2 way valve primary battery mounted Kit 2 way valve primary+additional battery not mounted Kit 2 way valve primary battery not mounted Semplied valve kit for CD version tted Semplied valve kit for CD version not tted Accessories for all versions Pair feet Vertical auxiliary condensate tray Horizontal auxiliary condensate tray (left connections) Horizontal auxiliary condensate tray (right connections) Condensate drain pipe El. resistance and relays tted on the unit (650 W) VC/HC El. resistance and relays tted on the unit (400 W) VC/HC El. resistance and relays tted on the unit (600 W) VC/HC El. resistance and relays tted on the unit (750 W) VC/HC El. resistance and relays tted on the unit (900 W) VC/HC El. resistance and relays tted on the unit (1000 W) VC/HC El. resistance and relays tted on the unit (1250 W) VC/HC El. resistance and relays tted on the unit (1500 W) VC/HC El. resistance and relays tted on the unit (2000 W) VC/HC El. resistance and relays tted on the unit (2500 W) VC/HC El. resistance and relays tted on the unit (700 W) CD El. resistance and relays tted on the unit (400 W) CD El. resistance and relays tted on the unit (600 W) CD El. resistance and relays tted on the unit (750 W) CD El. resistance and relays tted on the unit (900 W) CD El. resistance and relays tted on the unit (1000 W) CD El. resistance and relays tted on the unit (1250 W) CD El. resistance and relays tted on the unit (1500 W) CD El. resistance and relays tted on the unit (2000 W) CD El. resistance and relays tted on the unit (2500 W) CD Damper IM Frame Rear closing panel VC Rear closing panel HC Frontal air intake CD mounted Intake grid for VC Adaptor for terminal board VC for remote control Accessories only for concealed version CD Outlet ange 90 Inlet ange 90 Straight inlet ange Straight outlet ange Outlet spigot di user Air outlet grid Air inlet grid Air inlet spigot plenum Intake grid with lter (to be used in combination with inlet ange 90) Intake grid with lter (to be used in combination with straight inlet ange) 9066381 9066441 9066451 9066371 9066361 9066411 9066421 9066461 9066391 9066401 9066382 9060710 9060720 9066372 9066362 9060750 9060760 9066462 9060770 9060774 9066383 9060711 9060721 9066373 9066363 9060751 9060761 9066463 9060771 9060775 9066385 9060712 9060722 9066375 9066365 9060752 9060762 9066465 9060772 9060776 9066387 9060713 9060723 9066377 9066367 9066388 9060714 9060724 9066378 9066368 9060753 9060763 9066468 9060773 9060777 9060150 6060400 6060402 6060403 6060420 9066491E 9066611E 9066531 9062005 9060187 9066501 9060229 9066532 9060575 9060180 9060190 9066502 9060230 9066533 9060576 9060181 9060191 9066503 9060231 9066612E 9066613E 9066592E 9066602E 9066603E 9066605E 9066615E 9066535 9060577 9060182 9060192 9066505 9060232 9060103 9066537 9060578 9060193 9066507 9066593E 9066595E 9066597E 9066607E 9066617E 9066538 9060183 9060194 9066508 9060233 9066492E 9066493E 9066472E 9066482E 9066483E 9066485E 9066495E 9066473E 9066475E 9066477E 9066487E 9066497E 9060151 9066561 9060472 9066560 9060475 9060476 9060478 9066571 9066570 9060477 9060479 9060484 9060481 9060474 9060471
130/140 230/240 330/340 430/440

YFCN
530/540 630/640 730/740 830/840 930/940

9066467

Water Systems

Options / Accessories

york air-conditioning products

Dimensions
YFCN 130 to 940 (with casing)
B A 170 158 C 158

630

530

All dimensions in mm. Drawings not a scale. Model A B C 130 / 140 670 225 354 230 / 240 770 225 454 330 / 340 985 225 669 430 / 440 985 225 669 530 / 540 1 200 225 884 630 / 640 1 200 225 884 730 / 740 1 415 225 1 099 830 / 840 1 415 255 1 099 930 / 940 1 415 255 1 099

YFCN 130 to 940 (without casing)


A 511

100

1 0 0 71 44 125

133

119

17 12 A 22 22 12 B 153 10 C

153

511

12

12 29

All dimensions in mm. Drawings not a scale. Model A B C 130 / 140 374 218 354 230 / 240 474 218 454 330 / 340 689 218 669 430 / 440 689 218 669 530 / 540 904 218 884 630 / 640 904 218 884 730 / 740 1 119 218 1 099 830 / 840 1 119 248 1 099 930 / 940 1 119 248 1 099

71 44

125

133

153

18/19

Johnson Controls Intelligent Network Controllers

FX03 Controller
ControllerThe controller is designed specically to provide direct digital control of terminal unit applications with heating and/or cooling coils, an electric heater and a three-speed or variable speed fan. The device can be congured by the installer without the need of a PC and software tool, using a set of on-board dip-switches. The controller is designed for mounting by York OEM equipment FCU manufacturers on DIN-rail or directly on to the FCU surface.

Communication & Valves


The total assembly is completed in the factory; options for controllers include EUBAC approved systems or low cost congurable controllers. Further communication options enhance exibility with BACNet and LON made available at no extra cost. Valves and Valve kits are also exible, with modulating and on/o actuators, plus isolation valves if required tted to the valve kits. Installations are tested and delivered to site with software ready loaded.

Fancoil Factory Package over Typical Site Installed Controls


100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%

Save Time
Site Time is always precious, the more o site to benet the ow of the contract, the deliver the desired result. SmartPac Engineering is the control panels are standard and the savings are greater

Wiring & Installation Control Panel Commissioning Engineering Controls Site Fitted Manufacturer Factory Fitted SmartPac

Source: Johnson Controls

Water Systems

Smart Pac

york air-conditioning products

LASER & LOW BODY Fan Coil Units


2 & 4 pipe system
A complete range from 0.7 kW up to 9.9 kW

Features
6 speed fan Cabinet factory tted Valve factory tted Electrical heater factory tted Thermal or modulating valve Service valve Option front air intake (LASER) Optional plenum (LASER) Up to 110 pa static pressure (LASER)

CSL00 (Built in) CSR00 (Wall mounted) Fan speed selector

CML00 (Built in) CMR00 (Wall mounted) Thermostat with manual fan speed and S/W change over

CEL00 (Built in) CER00 (Wall mounted) Thermostat with manual fan speed and automatic change over CEL20 (Built in) CER20 (Wall mounted) Thermostat with auto. fan speed and automatic change over CEL30 (Built in) CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve

FX03 Terminal unit controller BacNET and N2 Metasys network compatible (see page 103 for details)

Technical features
Model Sizes Cooling capacity (1) Heating capacity (2) Pressure drop (4) Power supply Input Sound power level (3) Sound pressure level at 3 m (3) Water connections W W kPa V/Ph/Hz W dB(A) dB(A) inch LASER: YLV, YLV-AF, YLH, YLH-AF, YLIV, YLIV-AF, YLIH, YLIH-AF 110 112 114 216 218 220 222 224 226 1 169 1 746 2 291 3 467 3 804 4 664 5 570 6 789 7 599 1 628 2 296 2 981 4 514 5 076 6 013 7 304 8 677 9 800 3.9 7.6 6.5 13.8 13.6 23.1 31.6 18.8 20.9 230 / 1 / 50 + E 46 48 57 81 86 89 119 145 156 49 50 53 53 55 55 59 60 63 31 32 35 35 37 37 41 42 45 1/2 228 9 974 12 739 37.1 200 67 49 110 942 1 159 6.1 46 49 31 LOW BODY: YLVR, YLIVR 112 114 216 1 460 2 115 2 719 1 839 2 432 3 270 1.4 5.4 9.1 48 50 32 57 53 35 81 53 35 218 3 372 3 656 24.2 86 55 37

Dimensions indicated next page. (1) Cooling capacities based on 7C EWT t 5C indoor temperature 27C DB / 19C WB (2 pipes - high speed fan) (3 rows). (2) Heating capacities based on 50C EWT (LASER) / 70C EWT (LOW BODY) at nominal ow rate indoor temperature 20C (2 pipes - high speed fan) (3 rows for LASER and 1 row for LOW BODY). (3) Sound level at high speed fan . (4) In cooling mode. For other conditions contact Johnson Controls

20/21

0.7 to 9.9 kW

Compatibility table / Codes


Model Sizes With Cabinet YLV-YLH 2/3/4 rows YLV-YLH/AF Front air intake 2/3/4 rows YLVR 2/3 rows Without Cabinet YLIV-YLIH 2/3/4 rows YLIV-YLIH/AF Front air intake 2/3/4 rows YLIVR 2/3 rows Options (Factory tted) Coil and heaters 1 row heating BA1 Kit electrical heater (with relay and safety switch) KREL Built in thermostat Fan speed selector CSL00 Thermostat with manual fan speed CML00 and S/W change over Thermostat with manual fan speed, CEL00 dead band, automatic change over Thermostat with automatic fan speed, CEL20 dead band, automatic change over Thermostat with automatic fan speed, dead band, CEL30 automatic change over for modulating valve Parallel connection For ON/OFF valve one/FCU CBL20 For modulating valve one/FCU CBL30 3 way valve factory tted For 2 pipe systems ON/OFF J3A2 (2p) For 4 pipe systems ON/OFF J3A2 (4p) 3 way modulating valve factory tted For 2 pipe systems Modulating J3AM (2p) For 4 pipe systems Modulating J3AM (4p) Shut o valves factory tted For 2 pipe systems DT (2p) For 4 pipe systems DT (4p) Condensate pump PC WS sensor change over for CEL/CER WS Minimum temperature thermostat TM Accessories (Supplied loose) Remote controllers and thermostat (wall mounted) Fan speed selector CSR00 Thermostat with manual fan speed CMR00 and S/W change over Thermostat with manual fan speed, CER00 dead band, automatic change over Thermostat with automatic fan speed, CER20 dead band, automatic change over Thermostat with automatic fan speed, dead band, CER30 automatic change over for modulating valve Feet and panel (1) Set of painted feet CP1 Set of painted feet + frontal socle ZL1 Vertical painted back panel PPV1 Horizontal painted back panel PPH1 Plenums and air intake (1) Air intake plenum PA Air intake plenum with collars PAS 90 air intake plenum PA90 Air intake duct tting RCA Air delivery plenum with collars PM 90 air delivery plenum PM90 110

LASER 112

LOW BODY 222


114

216

218

220

224

226

228

110

112

114

216

218

(1) for check compatibility with the models of FCU see compatibility table on page 109

E-COM-H1106

Manufacturer reserves the rights to change specications without prior notice.

Water Systems

LASER & LOW BODY Fan Coil Units

york air-conditioning products

Dimensions & Weights


LASER: YLV - YLV/AF
VERTICAL
Dim A B C1 C2 D E F G H I J N O P 110 648 374 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 18 19 112 773 499 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 20 21

YLV & YLH V= vertical H= horizontal

YLV-AF & YLH-AF AF= front air intake V= vertical H= horizontal

YLVR R= low body V= vertical

114 898 624 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 23 24

216 1023 749 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 28 30

218 1148 874 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 31 32

220 1273 999 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 41 43

222 1273 999 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 44 46

224 1523 1249 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 52 54

226 1523 1249 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 52 54

228 1773 1499 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 58 61

LASER: YLH - YLH/AF


HORIZONTAL

Q R S T U V V1 W X Y Z kg1 kg2

Notes: 1=YLV / YLH - 2=YLV/AF / YLH/AF (All dimensions in mm)

Dim A B C D E G H J N O P Q R S T U V W X Z kg

110 648 374 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 15

112 773 499 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 17

114 898 624 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 22

216 1023 749 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 23

218 1148 874 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 26

LOW BODY: YLVR

(All dimensions in mm)

22/23

YLIV & YLIH V= vertical H= horizontal I= without cabinet

YLIV-AF & YLIH-AF AF= front air intake V= vertical H= horizontal I= without cabinet

YLIVR R= low body V= vertical I= without cabinet

LASER: YLIV - YLIV/AF


VERTICAL

Dim A A1 B C D D1 E F G H I J K L M

110 555 574 374 215 109 128 72 40 280 101 85 505 110 55 349 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 10

112 680 699 499 215 109 128 72 40 280 101 85 505 110 55 474 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 13

114 805 824 624 215 109 128 72 40 280 101 85 505 110 55 599 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 16

216 930 949 749 215 109 128 72 40 280 101 85 505 110 55 724 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 19

218 1055 1074 874 215 109 128 72 40 280 101 85 505 110 55 849 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 22

220 1180 1199 999 245 109 128 72 40 356 101 85 581 125 60 974 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 29

222 1180 1199 999 245 109 128 72 40 356 101 85 581 125 60 974 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 31

224 1430 1449 1249 245 109 128 72 40 356 101 85 581 125 60 1224 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 38

226 1430 1449 1249 245 109 128 72 40 356 101 85 581 125 60 1224 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 38

228 1680 1699 1499 245 109 128 72 40 356 101 85 581 125 60 1474 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 42

LASER: YLIH - YLIH/AF


HORIZONTAL

N O P Q R S T U V V1 W X Y Z kg

(All dimensions in mm)

LOW BODY: YLIVR

Dim A B C D E G H J K L M N O P Q R S T U V W X Y Z kg

110 555 374 230 108 73 170 101 395 61 349 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 9

112 680 499 230 108 73 170 101 395 61 474 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 11

114 805 624 230 108 73 170 101 395 61 599 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 14

216 930 749 230 108 73 170 101 395 61 724 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 16

218 1055 874 230 108 73 170 101 395 61 849 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 19

(All dimensions in mm)

Water Systems

Dimensions & Weights

york air-conditioning products

LASER and LOW BODY


Compatibility tables

Features CEL/CER
Dead band for change over 5C or 2C (factory set 2C) Manual fan speeds or automatic (models 20 and 30) Thermostated fan control or continuous fan running Option water sensor WS for change over on coil (for 2 pipes) Led indicated status summer, winter or dead band Temperature setting for 7 to 30C (comfort 20-25C) Plastic pins for limiting temperature range Input for window contact Input for Economy/ occupancy mode Output for remote alarm Filter alarm 600 or 1200 running hours (factory set 1200 hours) With electrical heater post ventilation With Air sensor in the air intake destratication function (CEL only)

CSL00 (Built in) CSR00 (Wall mounted) Fan speed selector

CML00 (Built in) CMR00 (Wall mounted) Thermostat with manual fan speed and S/W change over

CEL00 (Built in) CER00 (Wall mounted) Thermostat with manual fan speed and automatic change over CEL20 (Built in) CER20 (Wall mounted) Thermostat with auto. fan speed and automatic change over CEL30 (Built in) CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve

Compatibility table Thermostats / Valves / Heaters / Parallel connection / Water sensor / Minimum temperature thermostat
Factory tted thermostat (built in) CSL00 Fan speed selector CML00 Thermostat with manual fan speed and S/W change over CEL00 Thermostat with manual fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, CEL20 automatic change over fan speed, dead band, CEL30 Thermostat with automaticmodulating valve automatic change over for Remote controllers and thermostats (wall mounted) CSR00 Fan speed selector CMR00 Thermostat with manual fan speed and S/W change over CER00 Thermostat with manual fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, CER20 automatic change over fan speed, dead band, CER30 Thermostat with automaticmodulating valve automatic change over for Compatible Not compatible

Valves for 2 pipes J3A2 (2p)


Valves for 4 pipes J3A2 (4p)


Heaters KREL

J3AM (2p)

J3AM (4p)

Parallel connection ON/OFF Modulating CBL20 CBL30


Water sensor WS

Min. Temp. Thermostat TM


24/25

Compatibility tables

Compatibility Options / Accessories / Models


STANDARD LASER Code Designation YLV YLH YLV-AF YLH-AF YLIV CONCEALED YLIH YLIV-AF YLIH-AF LOW BODY YLVR YLIVR

Coils and heaters** BA1** Additionnal 1 row heating


KREL** Kit electrical heater with safety thermostat and relay Factory tted thermostat (built in) CSL00 Fan speed selector (buit in)

Thermostat with manual CML00 and S/W change over fan speed CEL00 CEL20 CEL30 CBL20 CBL30 Thermostat with manual fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, automatic change over for modulating valves Parallel connection for ON/OFF valve Parallel connection for modulating valve

Compatible with electrical heaters Compatible with electrical heaters


Remote controllers and thermostats (wall mounted) CSR00 Fan speed selector (wall mounted) Thermostat with manual CMR00 and S/W change over fan speed CER00 CER20 CER30 Thermostat with manual fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, automatic change over for modulating valves

Compatible with electrical heaters Compatible with electrical heaters


Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory tted) J3A2 (2p) 3-way 4-ports on/o valves for 2-pipe systems J3A2 (4p) 3-way 4-ports on/o valves for 4-pipe systems J3AM (2p) 3-way 4-ports modulating valves for 2-pipe systems J3AM (4p) 3-way 4-ports modulating valves for 4-pipe systems Shut-o valves for 2-pipe DT (2p) (in addition to J3A2/J3AMsystems valves) for 4-pipe DT (4p) Shut-o valvesJ3A2/J3AMsystems (in addition to valves) PC WS TM Condensate pump Water sensor Minimum temperature thermostat

Compatible with CEL/CER


Feet and panels CP1 ZL1 PPV1 PPH1 Set of painted feet Set of feet + frontal socle Vertical painted back panel Horizontal painted back panel

External air intake PA PAS PA90 RCA PM PM90

Air intake plenum Air intake plenum collars 90 air intake plenum Air intake duct tting Air delivery plenum with collars 90 air delivery plenum

**

Compatible Compatible with conditions Not compatible Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.

Water Systems

LASER and LOW BODY

york air-conditioning products

YEFB Hydro Blower


2 & 4 pipe system
A complete range from 3.2 kW up to 23.3 kW

Features
CSR00 (Wall mounted) Fan speed selector CER00 (Wall mounted) Thermostat with manual fan speed and automatic change over CER20 (Wall mounted) Thermostat with auto. fan speed and automatic change over CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve

Horizontal air return Twin centrifugal fans High static pressure up to 250 Pa Air distribution plenum Electric heater option Optional paint nish
FX03 Terminal unit controller BacNET and N2 Metasys network compatible (see page 103 for details)

CMR00 (Wall mounted) Thermostat with manual fan speed and S/W change over

Technical features at 50 Pa external static pressure


Model Total cooling capacity [kW] (1) YEFB max med min max med min max med min max med min G 1/2 F 130 6.00 5.13 3.22 7.89 6.61 3.96 1153 916 494 100 49.3 48.3 44.4 G 1/2 F G 1/2 F 140 6.91 5.81 3.49 8.90 7.32 4.20 1130 898 484 100 230 8.81 7.27 6.08 12.34 9.83 8.01 2158 1553 1174 175 55.6 52.6 49.1 230 - 1- 50 G 1/2 F G 1/2 F 240 10.60 8.55 7.01 14.62 11.36 9.04 2116 1523 1151 175 330 11.15 9.39 7.51 15.20 12.48 9.70 2639 1994 1422 250 58.7 54.2 48.5 G 1/2 F G 1 M 340 14.06 11.58 9.00 18.84 15.06 11.33 2587 1955 1394 250 430 17.86 16.28 14.39 24.38 21.83 18.90 4129 3505 2853 250 65.4 63.1 61.5 G 1 M 440 23.31 20.95 18.20 30.36 26.79 22.77 4048 3436 2797 250

Heating capacity [kW]

(2)

Air volume [m 3/h] Max. available external static pressure [Pa] Sound pressure level [dB(A)](3) Power supply [V-ph-Hz] Water connections

(1) Room temperature 27C d.b., 48% R.H. - Water temperature 7/12 C (2) Room temperature 20C, 50% R.H. - Water inlet temperature: 50C - Water ow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397 (3) Sound pressure level in 1 meter distance open eld and 0 Pa external static pressure

26/27

3.2 to 23.3 kW

Compatibility table / Codes


Models Options (factory tted) Auxiliary hot water coil (2 or 3 rows) Paint nish F5 Filter Accessories (supplied loose) Valve kits 3 ways 4 ports On/o 2 and 4 pipes Modulating 2 and 4 pipes Electrical heaters Capacity (W) Controls CSR00 fan speed selector CMR00 2 and 4 pipe, on/o valves CER00 2 and 4 pipe, on/o valves (or El. heater) CER20 2 and 4 pipe, on/o valves (or El. heater) CER30 2 and 4 pipe, modulating valves Discharge plenum Condensate pump

YEFB 130-140

YEFB 230-240

YEFB 330-340

YEFB 430-440

J3B2 J3BM

J3C2 J3CM

3000

6000

9000

H G

KPM 100-200

91.5 160

KPM 300

KPM 400

KPC 100-400
D

Available

Dimensions and minimum spaces

351 B

H G E 91.5 160

C
D

200
F

78

Mod. 100-200 300 400

A 990 1 240 1 630

B 800 900 900

C 330 350 440

D 949 1 199 1 592

E 290 309 398

F 21.5 21.5 21.5

G 362 462 450

H 158 158 158

Mod. 100-200 300 400

A 330 350 440

B 954 1 204 1 597

C 306 300 311

All dimensions in mm
351 B A

All dimensions in mm

E-COM-H1107

Manufacturer reserves the rights to change specications without prior notice.


C 78

200

Water Systems

YEFB Hydro Blower