W A T L O W
Tubular and
Thermostats Accessories
Process Assemblies
Thermostats and Thermostats with Enclosures
Accessories NEMA 1 Single and Double Pole NEMA 4 and 12 Single Pole
Thermostats regulate temperature in 3 3/16
(91 mm)
non-critical applications. They sense
temperature, within a preset range 3 1/4"
2 3 /4 7 /16
(83 mm)
and cycle heaters on and off to 2 /32"
5
3 5 /16"
(70 mm) (88 mm)
Tubular and
Process Assemblies
Thermostats and
Accessories
Application Hints
• Locate the thermostat where circuit breaker to cut power when Warning
ambient temperatures do not servicing. Do not use thermostats for high-limit
exceed 150°F (65°C). • Interconnect the thermostat to the sheath protection. Thermostats fail
• Mount the thermostat in an heater only if: in a closed circuit mode and will not
enclosure that is compatible with - The heater has one circuit cut power to the heaters. Limit
the surrounding environment. control should be provided by an
- The heater’s ampere draw is isolated, redundant sensor and
• Immerse the entire sensing bulb lower than the thermostat’s rated control system of the appropriate
in the media being heated. ampacity at prescribed voltage. type, design and installation.
• Make sure the sensing bulb is • Interconnect either a single or Thermostats are precalibrated at the
mounted away from the heating double pole thermostat with a factory. No adjustment, other than
element(s) to negate any undue single-phase heater when the selecting the desired operating
influence on the sensing bulb’s supply voltage does not exceed temperature, is required. All wiring
temperature “reading.” 277VÅ(ac) for SPST or 480VÅ(ac) should be performed by qualified
• Keep the capillary tube insulated for DPST. personnel and comply with the
from electrical connections. • Only interconnect three-phase National Electrical Code and other
• Do not use a thermostat for high- delta heaters to DPST applicable state and local codes.
accuracy temperature sensing. thermostats. To help assure you select the
Use an appropriate • Use a single pole thermostat for correct thermostat, as well as install
thermocouple, RTD or thermistor pilot duty where the thermostat is and wire it properly, we have put
and temperature control. not interconnected with the together a few helpful hints.
• Do not use thermostats as a heater, or heater exceeds the Schematics are provided for
primary power switching device. volt/amp rating. interconnecting thermostats to
Use a disconnect switch or single- and three-phase heaters.
1 L2
1 L2
1 L3
1 L3 1 L2
SPST SPST
SPST
120VÅ(ac) 120VÅ(ac)
P P
120VÅ(ac)
P
Interconnected Wiring
SPST, 1-phase DPST, 1-phase DPST, 3-phase delta
SPST 1 L1
DPST DPST
1 L1 1 L1
P
P
P 1 L2
1 L2
1 L3
1 L2
424
3 Thermostats&Access 11/22/00 11:04 AM Page 425
W A T L O W
Tubular and
Thermostats Accessories
Process Assemblies F.O.B.: Hannibal, Missouri
Thermostats and
Accessories
Thermostat
Control Temperature Ampacity @ Bulb Bulb Capillary Terminal Code Est. Net
Mode Type Range Differential Line Voltage Diameter Length Length Type No. Weight
°F (°C) ˚F (˚C) 120 240 277 480 inch (mm) inch (mm) inch (mm) lbs (kg)
On-off Single 30-110 (0-40) 8 (0) 25 25 22 — 0.250 (6) 4 3⁄4 (121) 18 (455) 1 1 (0.4)
Temp Pole 30-250 (0-120) 15 (8) 25 25 22 — 0.250 (6) 3 1⁄4 (85) 18 (455) #12 AWG 2 1 (0.4)
Control Single 30-250 (0-120) 15 (8) 25 25 22 — 0.250 (6) 3 1⁄4 (85) 84 (2135) Stranded 2A 1 (0.4)
Throw 175-550 (80-290) 26 (14) 25 25 22 — 0.250 (6) 3 3⁄8 (85) 18 (455) Leads 3 1 (0.4)
(SPST) 175-550 (80-290) 26 (14) 25 25 22 — 0.250 (6) 2 3⁄4 (70) 84 (2135) 3A 1 (0.4)
300-700 (150-350) 12 (7) 25 25 — — 0.375 (10) 3 3⁄4 (95) 60 (1525) 10 1 (0.4)
60-160 (15-70) 19 (10) 30 30 30 20 0.250 (6) 4 3⁄8 (110) 14 (355) #8-32 12A 1 (0.4)
Double 30-110 (0-40) 12 (7) 30 30 30 21 0.375 (10) 6 1⁄4 (160) 36 (915) 4 2 (0.9)
Pole 60-250 (15-120) 12 (7) 30 30 30 21 0.375 (10) 4 1⁄2 (115) 48 (1220) #10-32 5 2 (0.9)
Single 60-250 (15-120) 12 (7) 30 30 30 21 0.250 (6) 6 1⁄2 (165) 48 (1220) Screw Lug 5A 2 (0.9)
Throw 100-550 (40-290) 22 (12) 30 30 30 21 0.375 (10) 3 7⁄8 (100) 48 (1220) 7 2 (0.9)
(DPST) 100-550 (40-290) 22 (12) 30 30 30 21 0.250 (6) 7 1⁄16 (179) 48 (1220) 7A 2 (0.9)
On-off (DPST) 60-250 (15-120) 12 (7) 30 30 30 — 0.250 (6) 6 1⁄2 (165) 48 (1220) #10-32 8 2 (0.9)
with 100-550 (40-290) 22 (12) 30 30 30 — 0.188 (8) 12 (305) 48 (1220) Screw Lug 9 2 (0.9)
Manual (SPST) 350➀ (180) — 30 30 20 — 0.250 (6) 3 1⁄2 (90) 36 (915) #10-32 11 1 (0.4)
Reset Screw Lug
425
3 Thermostats&Access 11/22/00 11:04 AM Page 426
Tubular and
Process Assemblies F.O.B.: Hannibal, Missouri
426