You are on page 1of 16

air ConditioninG

GUIDE TO THE PRODUCTS FOR AIR CONDITIONING

Lark CentraL air Conditioner

iSo9001:2000 standard
Add: No.88 Shenzhen Road, Zaozhuang city Shandong P.R.China 277800 Tel: 0086-531-88926116 Fax: 0086-531-88929119 Email: info@sdlark.com larkairsale@hotmail.com www.sdlark.com

Lark Central Air Conditioner


Company Introduction

Contents
Company Introduction................................................................................. 01 Air to Air Packaged Rooftop Unit ..............................................................02 Air to Air Ducted Split Unit ..........................................................................04 Top Discharge Condensing Unit ................................................................ 06 Air to Water Chiller & Heat Pump Unit....................................................... 08 Air to Water Modular Chiller & Heat Pump Unit ....................................... 10 Air to Water Screw Chiller & Heat Pump ................................................... 12 Water Source Heat Pump ............................................................................ 14 Water Cooled Modular Scroll Chiller & Heat Pump ................................. 16 Water Cooled Screw Chiller ........................................................................ 20 Ground Source Heat Pump ......................................................................... 24 Fan Coil Unit (Water Chilled)....................................................................... 28
4

Lark central air conditioner is dedicated to top class air conditioning: rooftop packaged unit, ducted split unit, air condensing unit, air source heat pump, ground source heat pump and fan coil etc.

Our efforts to ensure high quality and top graded level products begin in the designing lab and manufacturing sites, we invest to use advanced equipments in on-line inspection room and national standard testing room.

As a manufacturer and provider of high-quality air conditioning and solutions, Lark controls the comfort and assures the high quality.

Lark is continuously striving to further develop and enhance its products.

01

Air to Air Packaged Rooftop Unit


Cooling capacity from 9.6 to 188.5 kW Heating capacity from 10.6 to 202 kW

Technical Data
Model Cooling Cooling capacity * Total power input * Heating Heating capacity * Total power input * Compressor Type Air treatment section Centrifugal fans number Drive type Air flow External static pressure Motor power Condensation section Axial fans number Air flow Motor power Net weight Sound pressure level ** unit kW kW kW kW 10 9.6 4.01 10.6 3.79 12 11.3 4.43 12.4 4.16 14 13.1 5.25 14.4 4.97 17 17.2 6.65 18.9 6.02 Scroll Nr. / m3/h Pa kW Nr. m3/h kW kg dB(A) 1 Direct 1800 160 0.55 1 3961 0.16 240 67 1 Direct 2124 150 0.55 1 3781 0.16 240 67 1 Direct 2520 180 0.55 1 5509 0.33 243 68 1 Direct 2916 175 0.76 1 7021 0.38 360 71.7 1 Direct 3600 225 0.93 1 8641 0.38 402 72.6 1 Direct 4248 185 0.93 1 8641 0.48 420 72.6 1 Belt 4500 260 1.22 1 9434 0.61 461 70.0 1 Belt 5400 240 1.22 1 9434 0.61 461 70.0 20 19.2 7.49 21.1 6.73 22 22.5 8.66 24.8 8.29 25 24.4 9.14 26.5 8.68 28 26.2 10.56 28.8 9.99

Rooftop Packaged Unit


Outdoor and Roof Top installation

Functions

Cooling

C&H

Free Cooling

Model Cooling Cooling capacity * Total power input * Heating Heating capacity * Total power input * Compressor Type Air treatment section Centrifugal fans number Drive type Air flow External static pressure Motor power Condensation section Axial fans number Air flow Motor power Net weight Sound pressure level **

unit kW kW kW kW

30 29.3 11.43 31.4 10.53

32 31.4 11.57 33.6 10.76

35 34.5 13.03 36.9 11.83

42 40.4 15.05 43.3 13.4 Scroll

45 45.8 17.08 48.7 16.36

52 51.6 19.14 54.7 18.49

63 61.4 24.07 65 21.49

75 69.3 27.83 73.3 26.06

Characteristics
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents Direct expansion coils with condensate drain tray

Structure

Cooling/Heating/Auto Error indication Timing on/off

Easy operation line controller:

High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise

Hermetic compressor

Forward curve centrifugal fans for air treatment section and axial fans for condensation section Front, side and underside air discharge of the treatment unit High external pressure, long air supply distance

Centrifugal fan

Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components

Electric panel

Economizer with fresh, return air dampers and fresh air hood Free cooling function for low ambient temperature Low ambient control device for operation of outdoor units at ambient temperatures from less than 20C down to -10C BMS devices T3 (Tropical Climate) Condenser coil guard Roof curb Metal / aluminum filter Air pressure switch for indoor fan High static condenser fan option with sealed + drain condensing section Optional water heating coil Metal or plastic mesh on condenser coil Optional supply / return air configurations Upgraded evaporator fan motor drives G4 filter, plate and bag filter

Optional

Nr. / m3/h Pa kW Nr. m3/h kW kg dB(A)

1 Belt 5688 260 1.5 1 11234 0.80 503 72.0

1 Belt 6300 250 1.5 1 12314 0.80 505 72.0

1 Belt 6804 260 2.2 2 15000 20.37 650 72.0

1 Belt 7920 250 2.2 2 17600 20.45 725 72.0

1 Belt 9360 260 3 2 18800 20.55 801 75

1 Belt 10440 350 3 2 21420 20.55 884 75

1 Belt 12672 320 3 2 24620 20.75 890 75

1 Belt 14400 360 4 2 30000 21.1 980 75

Nomenclature
L AA H C P 10 L: Lark air product Unit type AA: Air to Air AW: Air to Water WA: Water to Air WW: Water to Water C: Cooling only H: Heat pump Refrigerant type --: R22 A: R410a B: R134a C: R407c Type of unit P: Packaged type S: Split type Model

Model Cooling Cooling capacity * Total power input * Heating Heating capacity * Total power input * Compressor Type Air treatment section Centrifugal fans number Drive type Air flow External static pressure Motor power Condensation section Axial fans number Air flow Motor power Net weight Sound pressure level **

unit kW kW kW kW

90 87.2 31.40 93.3 29.83

105 103.1 38.30 109.5 36.78

120 118.8 46.10 126.8 42.90

140 131.2 49.70 141.2 45.70 Scroll

155 153.4 56.70 164.3 50.70

170 168.6 65.40 182 59.28

190 188.5 75.48 202 69.40

Nr. / m3/h Pa kW Nr. m3/h kW kg dB(A)

1 Belt 16560 350 4 2 40000 21.5 1160 75

1 Belt 19440 350 5.5 2 40000 21.5 1450 75

1 Belt 22032 460 7.5 4 49240 40.75 1910 80

1 Belt 24300 450 7.5 4 49240 40.75 2010 80

1 Belt 29160 410 7.5 4 60000 41.5 2280 80

1 Belt 33120 410 11 4 80000 41.5 2460 82

1 Belt 36720 460 15 4 80000 41.5 2530 82 .5

* Performance values refer to the following conditions: Cooling: room air temperature 27.0C DB RH 50%, ambient air temperature 35C; Heating: room air temperature 21.0C DB, ambient air temperature 7C DB / 6C WB; ** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.

02

03

Air to Air Ducted Split Unit


Cooling capacity from 19.5 to 103.7 kW Heating capacity from 22.6 to 115.8 kW

Technical Data
Model Nominal cooling capacity* Nominal heating capacity** Connection Method Liquid pipe diameter Gas pipe diameter Compressor Qty/circuit nr. OUTDOOR UNIT Cooling power input* Heating power input** Energy adjustment Axial fans Quantity Air flow Sound pressure level*** Net weight Centrifugal fans INDOOR UNIT Quantity Air flow ESP Sound pressure level*** Net weight Additional electric heater**** Nr. m3/h Pa dB(A) kg kW kW 2 3500 120 64 90 23 22.2 2 4500 100 64 100 24 28.4 2 5650 150 66 150 25 35.1 2 6450 130 66 160 26 40.0 2 7400 180 68 180 26 46.0 2 8550 200 68 200 28 53.3 Nr. m3/h dB(A) kg 1 9400 67 170 1 9400 67 180 1 12500 68 220 1 14200 70 230 2 18800 71 260 2 18800 71 280 Nr. kW kW % 2/2 7.2 7.13 50-100 2/2 9.3 9.21 50-100 2/2 11.8 11.68 50-100 1/1 12.8 12.67 0-100 2/2 15.1 14.95 40-60-100 2/2 17.9 17.72 33-66-100 / mm mm Flare 9.522 15.882 Flare 12.72 19.052 Flare 12.72 19.052 Welding 15.881 281 Welding 15.88/12.7 28/19.05 Welding 15.88/12.7 28/19.05 unit kW kW 20 19.5 22.6 25 24.8 28.9 32 31.2 35.8 36 35.6 40.8 42 41.3 46.9 48 47.4 54.4

Ducted Split Unit


Outdoor and Indoor installation

Functions

Cooling

C&H

Additional heating coil****

Characteristics
11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.Cooling only and heat pump version Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers Compact indoor design, long air supply distance Outdoor units are equipped with low noise axial fans Indoor units are equipped with quiet centrifugal fans Split installation, connected by means of flare/welding coupling Easy operation line controller Cooling/Heating/Fan/Auto Error indication Timing on/off Multi safety protection High/low pressure protection Overheat protection Current overload protection Phase sequence relay Time delay and antifreeze switch

Model Nominal cooling capacity* Nominal heating capacity** Connection Method Liquid pipe diameter Gas pipe diameter Compressor Qty/circuit nr. OUTDOOR UNIT Cooling power input* Heating power input** Energy adjustment Axial fans Quantity Air flow Sound pressure level*** Net weight Centrifugal fans INDOOR UNIT Quantity Air flow ESP Sound pressure level*** Net weight Additional electric heater**** Additional heating coil****

unit kW kW / mm mm Nr. kW kW % Nr. m3/h dB(A) kg Nr. m3/h Pa dB(A) kg kW kW

52 51.3 58.9 Welding 15.88/12.7 28/19.05 2/2 18.4 18.22 30-70-100 2 21500 71 330 2 9250 200 68 220 28 57.8

62 63.3 72.6 Welding 15.882 282 2/2 23.1 22.87 50-100 2 26500 71 340 2 11450 300 68 230 210 71.2

72 71.3 81.9 Welding 15.882 282 2/2 26.6 26.33 50-100 2 29880 71 460 2 12900 300 69 300 210 80.3

88 87.9 100.0 Welding 15.882 282 2/2 28.1 27.82 50-100 2 36500 71 780 2 14800 280 69 320 212 98.0

104 103.7 115.8 Welding 19.052 352 2/2 39.3 38.91 50-100 2 43500 71 800 2 17100 500 70 400 214 113.5

Optional

Electric heater Hot water coil T3 (Tropical climate)

Nomenclature
L AA H C S 20 W/N

L: Lark air product Unit type AA: Air to Air AW: Air to Water WA: Water to Air WW: Water to Water

C: Cooling only H: Heat pump Refrigerant type --: R22 A: R410a B: R134a C: R407c Type of unit P: Packaged type S: Split type(Ducted split)

Model Unit name W: Outdoor unit N: Indoor unit W/N: The whole unit

Performance values refer to the following conditions: * Cooling capacity is measured under the condition: indoor temperature DB 27 / WB 19 , ambient temperature DB 35 / WB 24 ; ** Heating capacity is measured under the condition: indoor temperature DB 20 / WB 15 , ambient temperature DB 7 / WB 6 ; *** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field. **** Optional as request.

04

05

Top Discharge Condensing Unit


Cooling capacity from 17600 to 55500Btu/h

Overall Dimensions
Model D W H D E unit mm mm mm lnch lnch 18/24 574 574 635 5/8 3/8 30/36 574 574 735 5/8,3/4 3/8 48/60 768 768 735 3/4,7/8 3/8

Technical Data
Model unit 18 24 30 36 48 60 60/(3PH)

Top Discharge Condensing Unit


Outdoor installation

Performance Rated cooling capacity* SEER** Compressor Type Fan Size inch Nr. / inch W A Rpm 20 3 35 1/26 1/2 188 1.3 1100 20 3 35 1/26 1/2 188 1.3 1100 20 3 35 1/26 1/2 188 1.3 1100 20 3 35 1/26 1/2 188 1.3 1100 23 1/4 3 35 1/23 1/2 320 2.5 1030 23 1/4 3 35 1/23 1/2 320 2.5 1030 23 1/4 3 35 1/23 1/2 320 2.5 1030 / Rotary Rotary Scroll Scroll Scroll Scroll Scroll Btu/h Btu/h-W 17600 13 22600 13 28600 13 34500 13 47000 13 55500 13 55500 13

Functions

Cooling

C&H

No. Blades-CW/CCW Angle (Apx. Deg.) Venturi diawidth

Characteristics
13 SEER efficiency range Capacity : 17600Btu/h-55500Btu/h Cooling only and heat pump version State-of-art compressor Coils are constructed of copper tubing with protected aluminum fins for durability and long lasting efficient operation Plastic net coil guard is optional Operating sounds are minimized through upward discharge air flow All units are fully tested and charged with refrigerant before delivery Long life permanently lubricated motor-bearings need no annual servicing Fully exposed refrigerant connections All the components are quality brand

Motor watts Motor amps Motor rpm Electrical data Voltage Range Total amps Minimum circuit ampacity Maximum circuit breaker Power input watts Coil Rows Fins per inch Fin width

V/Ph/Hz V A A A W 197-253 9.4 10.3 20 1910 197-253 14 15.4 25 2530

208~230/1/60 197-253 14.9 17.0 30 3150 197-253 17.8 20.3 35 3750 197-253 21.0 24.2 50 5050 197-253 30.7 36.8 60 6320

208~230/3/60 197-253 19.8 24.5 40 6320

Nr. Nr. mm / inch Nr. Nr.

1 13 2.0 TP2M 3/8 22 2

1 16 1.6 TP2M 3/8 22 2

1 22 1.16 TP2M 3/8 24 2

1 22 1.16 TP2M 3/8 26 2

1 22 1.16 TP2M 3/8 24 3

1 22 1.16 TP2M 3/8 26 3

1 22 1.16 TP2M 3/8 26 3

Nomenclature
L AA C A T 60 C: Cooling only H: Heat pump Refrigerant type --: R22 A: R410a B: R134a C: R407c T: Top discharge Model

Tube type Tube diameter No. of tubes No. of circuit Refrigerant Type Net weight

L: Lark air product Unit type AA: Air to Air AW: Air to Water WA: Water to Air WW: Water to Water

/ kg

R410A 50

R410A 56

R410A 68

R410A 72

R410A 80

R410A 92

R410A 92

* The performance values refer to the following conditions: outdoor temperature DB 35C (95F), WB 24C (75F); ** SEER: rated in accordance with ARI 210-895 and D.O.E. Test Standards.

06

07

19

Nomenclature
L AW H R P A 10 L: Lark air product Unit type AW: Air to Water AA: Air to Air C: Cooling only H: Heat pump Heat recovery type --: Without heat recovery R: With heat recovery Heat exchanger T: Tube in tube type P: Plate type Refrigerant type --: R22 A: R410a B: R134a C: R407c Model

Technical Data

Air to Water Chiller & Heat Pump Unit


Cooling capacity from 8.1 to 51 kW Heating capacity from 9.7 to 59 kW

Model Cooling Cooling capacity Heating Heating capacity Heat recovery capacity

unit

10

12

16

18

22

25

28

30

36

42

46

50

kW

8.1

11

12.2

15

17

22.2

24.5

27.8

30

35.9

41

45.2

51

kW kW

9.7 2.03

13.5 2.75

14.5 3.05

16.5 3.75

17.5 4.25

27 5.55

29 6.13

33 6.95

35 7.5

42.5 8.98

47.5 10.25

53 11.3

59 12.75

Air to Water Chiller & Heat Pump Unit


Outdoor installation COP 3.6 (360% efficient)

Functions

Hermetic compressor (380V/3N/50Hz) Type Quantity/circuit Total Cooling input 1* / / kW / kW / kW / 1 2.81 2.88 2.81 3.45 2.09 4.7 1 3.83 2.87 3.83 3.52 2.85 4.8 1 4.1 2.98 4.1 3.54 3.05 4.82 1 4.44 3.38 4.44 3.72 3.31 5.06 1 4.88 3.48 4.89 3.58 3.64 4.88 2/2 2x3.83 2.9 2x3.83 3.52 5.71 4.8 Scroll 2/2 2/2 2/2 2/2
4.44+7.28

2/2

2/2

2/2 2x8.13 3.14


2x8.04

2x4.1 2x4.44 2x4.88 2.99 2x4.1 3.54 6.11 4.82 3.13 3.07

4.88+8.13 4.88+7.79

Characteristics
Averaging COP (efficiency) over 3.6 and importantly the performance when operating in lower ambient temperatures is also at a very high level. Designed to operate in ambient temperatures as low as -15C provide heating or cooling and hot water up to 55C

Cooling

C&H

Heat Recovery

EER Total Heating input 2* COP Total Heating input 3* COP Evaporator Type Water fow when cool Water side pressure drop Water connection size Circulating pump Power input Axial fans Quantity Air flow Desuperheater Type Water flow Water connection size Overall dimension Length Width Height Noise level 4* Net weight

3.06
4.44+7.2

3.15

3.57

2x4.44 2x4.89 3.72 6.62 5.06 3.58 7.29 4.88

4.89+8.04 4.89+9.68

insulated with flexible close cell material (optional)

3.65 8.67 4.97

3.67 9.63 5.01

3.64 10.85 4.96

3.67 11.98 5.00

Refrigerant circuit
Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, thermostatic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve

Structure
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents

/ m3/h kPa inch 1.4 33 1.9 33 2.1 33 DN25 2.6 36 DN25 2.9 38 DN25

Plate heat exchanger 3.8 38 DN40 4.2 39 DN40 4.8 42 DN40 0.75 5.2 50 DN40 6.2 52 DN40 7.1 52 7.8 52 8.8 52 DN40

DN25 DN25

DN40 DN40

Compressor
Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators

Water circuit
Built with air vent valve, water drain connection, and female-threaded hydraulic connectors Water pump (8kw-30kW),differential pressure switch Expansion tank (8kw-30kW)

kW

0.093

0.093

0.4

0.4

0.4

0.75

0.75

0.92

------

------

------

------

Nr. m3/h

1 4500

1 4500

2 4500

2 9000

2 9000

2 9000

2 9000

2 12580

2 21000

2 21000

2 21000

2 22000

2 24000

Axial fan
External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, provided with a protective outlet grille

Electric panel
Consists of: Compressor contactor Compressor protection breaker Fan motor protection breaker Control circuit protection breaker Phase sequence relay (only for 3-phase) Programmable microprocessor controller

/ m3/h inch 035 DN20 0.47 DN20 0.52 0.64 0.73

Plate heat exchanger 0.95 19mm 1.05 1.2 1.29 1.54 1.76 DN20 1.94 DN25 2.19 DN25

DN20 19mm 19mm

19mm 19mm 1600 900 1080 66 200 1600 900 1080 69 260

19mm DN20

Evaporator
High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with anti-freeze heating element (option) and differential pressure switch, factory insulated with flexible close cell material

mm mm mm dB(A) kg

1250 452 1180 56 145

1250 452 1180 60 150

1250 452 1180 60 150

1250 452 1180 62 180

1250 452 1180 62 190

1250 452 1180 66 190

1600 900 1080 69 275

2000 900 1080 72 310

2000 900 1080 73 320

2000 900 1080 73 340

2000 900 1080 74 360

Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, 100% fully quality tested; sub cooling circuit to prevent freezing at the base (optional); protected with metal grill

Optional
Additional electric heater embedded in the coils for defrosting in low temperature ambient. It must be factory installed Stainless steel covering Remote condenser Tube in tube heat exchanger Electric heater

Desuperheater
High efficiency stainless steel brazed plate heat exchanger, factory

1* Ambient temperature 35C; user side water in/out 12/7C; 2* Ambient temperature 7C; user side water in/out 40/45C; 3* Ambient temperature 7C; user side water in/out 30/35C; 4* Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in an ideal field (fan side).

08

09

Air to Water Modular Chiller & Heat Pump Unit


Cooling capacity from 60 to 101.3 kW Heating capacity from 66 to 106.3 kW

Air to Water Modular Chiller & Heat Pump Unit


Outdoor installation

Functions

Cooling

C&H

Heat Recovery

Characteristics
The master module can work independently or together with up to 15 slave modules, cooling capacity from 60 to 1621kW

Structure

high & low pressure switch. The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve

3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers

Hermetic compressor

Hydraulic circuit

Technical Data
Model Capacity Cooling * Heating ** kW kW 60 66 79 83.1 101.3 106.3 unit 60 80 100

Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units

External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille

Axial fan

Electric panel

Evaporator built with high efficiency tube in tube type heat exchanger, factory insulated with flexible close cell material

Evaporator

Electric panel consist of: compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit) Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system

Compressor Qty/refrigerant circuit Cooling power input* Heating power input** Energy adjustment Axial fan Quantity Air flow Evaporator Type Water flow Water side pressure drop *** Noise level**** Dimensions Length mm mm mm kg 2230 1140 1850 760 2330 1320 1970 1000 3000 1200 1920 1240 / m3/h kPa dB(A) 10.3 49 71 Tube in tube heat exchanger 13.76 39 71 17.2 38 73 Nr. m /h
3

Nr. kW kW %

2 23.2 25.8 0-50-100

2 26.1 27.2 0-50-100

3 31.44 33.6 0-33-66-100

Optional
Paddle Metallic

Condenser built with seamless internal screw thread copper tubes mechanically expanded into blue wave hydrophilic aluminum fins

Condenser

Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve,

Refrigerant circuit

flow switch filter for hydraulic circuit Water pump Rubber anti-vibration mounting BMS Stainless steel covering Heat recovery 20%-25% Flange Remote condenser Four compressors/six compressors

2 30000

2 42000

3 48000

Nomenclature
L AW H R T C MM 80 L: Lark air product Unit type AA: Air to Air AW: Air to Water WA: Water to Air WW: Water to Water C: Cooling only H: Heat pump Heat recovery type --:Without heat recovery R:With heat recovery Heat exchanger T: Tube in tube type P: Plate type Refrigerant type --: R22 A: R410a B: R134a C: R407c Modular type MM: Modular master MS: Modular slave Model

Width Height Net weight

* Ambient temperature 35C; user side water in/out 12/7C; ** Ambient temperature DB 7C, WB 6C; user side water in/out temperature 40/45C; *** In the nominal water flow condition the pressure drop is between this range; **** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field (fan side).

10

11

Air to Water Screw Chiller & Heat Pump


Cooling capacity from 152.1 to 752.4 kW Heating capacity from 174.4 to 856.6 kW

Technical Data
Model Cooling capacity * Heating capacity * Compressor Qty/refrigerant circuit Cooling power input * Heating power input * Energy adjustment steps Evaporator Water flow rate Water side pressure drop Axial Fan Fan motor number Air flow Sound pressure level ** Net weight Nr. m3/h dB(A) kg 4 96000 76 1950 4 96000 76 2150 6 144000 77 2500 6 144000 77 2900 8 192000 78 3650 10 240000 80 4450 m3/h kPa 26.2 41 31.8 41 42.6 42 54.3 43 64.7 42 74.4 44 Nr. kW kW step 4/2 47.2 46.3 4 4/2 58.4 57.9 4 1/1 73.4 72.8 4 1/1 97.2 96.3 4 1/1 115.7 113.6 4 2/2 125.1 123.9 8 unit kW kW 150 152.1 174.4 180 184.9 211.6 250 247.6 277.6 320 315.6 361.5 380 376.2 428.3 430 432.5 489.2

Air to Water Screw Chiller & Heat Pump


Outdoor installation

Functions

Model

unit kW kW Nr. kW kW step m3/h kPa Nr. m3/h dB(A) kg

500 495.6 555.2 2/2 154.2 152.7 8 85.2 43 12 288000 81 4950

570 563.2 639.1 2/2 170.6 169.1 8 96.9 43 12 288000 81 5450

640 631.2 723.0 2/2 194.4 192.7 8 108.6 44 12 288000 81 5750

700 691.8 789.8 2/2 212.9 209.9 8 119.0 45 14 336000 82 6650

760 752.4 856.6 2/2 222.3 220.2 8 129.4 45 16 384000 83 7250

Cooling

C&H

Heat Recovery

Cooling capacity * Heating capacity * Compressor Qty/refrigerant circuit

Characteristics
11 sizes available ranging from 151.2 kW to 752.4 kW cooling capacity Hermetic scroll compressor for mod. 150 to 180, semihermetic screw compressor for mod. 250 to 760. Each compressor is equipped with a crankcase heater and a thermal overload cut-out; the screw compressor is also complete with a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille Evaporator built with high efficiency shell and tube type heat exchanger, factory insulated with flexible close cell material. Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve, high & low pressure switch. The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve Hydraulic circuit built with galvanized pipe, complete with water discharge connection for shell and tube heat exchanger and flange type hydraulic connectors Electric panel consist of: compressor contactor, fan motor contactor, compressor isolating switch, fan protection breaker, phase sequence relay and microprocessor with function display Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system

Cooling power input * Heating power input * Energy adjustment steps Evaporator Water flow rate Water side pressure drop Axial Fans Fan motor number Air flow Sound pressure level ** Net weight

OPTIONAL

Metallic filter for hydraulic circuit Rubber antivibration mounting Remote condenser BMS Modular design T3 (Tropical climate) Heat recovery Plate heat exchanger

* The performance values refer to the following conditions: Cooling: ambient air temperature 35C; evaporator water in/out temperature 12/7C; Heating: ambient air temperature DB 7C, WB 6C; condenser water in/out temperature 40/45C. ** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.

Overall Dimensions
Model 150 180 250 320 380 430 500 570 640 700 760 A 2500 2500 3290 3590 4680 5800 6590 6890 7190 8290 9270 B 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 C 2230 2230 2230 2230 2230 2230 2430 2430 2430 2430 2430

Nomenclature
L AW H R S C 150 L: Lark air product Unit type AW: Air to Water AA: Air to Air C: Cooling only H: Heat pump Heat reco very type --: Without heat recovery R: With heat recovery Heat exchanger T: Tube in tube type P: Plate type S: Shell and tube type Refrigerant type --: R22 A: R410a B: R134a C: R407c Model C

A B

12

13

Cooling capacity from 4.77 to 140 kW Heating capacity from 5.1 to 163.9 kW

Water Source Heat Pump

Nomenclature
L WW H R P C 10 L: Lark air product Unit type WA: Water to Air WW: Water to Water C: Cooling only H: Heat pump Heat recovery type --: Without heat recovery R: With heat recovery Heat exchanger T: Tube in tube type P: Plate type Refrigerant type --: R22 A: R410a B: R134a C: R407c Model

Technical Data
Model
unit

5 4.77 5.1 4.3 1/1 0.98 1.18

7 6.9 7.38 4.4 1/1 1.38 1.66

8 9.02 9.67 4.69 1/1 1.66 2.06 20

10 10.82 11.86 4.32 1/1 1.96 2.74

12 12.83 14.35 4.3 1/1 2.36 3.34

14 14.75 17.16 4 1/1 2.64 4.12

16 17.18 18.82 4.6 1/1 2.94 4.12

20 20.89 22.36 4.7 2/2 3.44 4.78 25

25 26.62 28.7 4.8 2/2 4.42 5.88

30 31.93 34.22 4.9 2/2 5.52 6.96

Water to Water Unit


Indoor or outdoor installation Heat recovery rate: 20%-25%

Nominal cooling capacity* Nominal heating capacity** COP Hermetic compressor Qty/circuit nr. Cooling power input* Heating power input** User side heat exchanger Pressure drop

kW kW / Nr. kW kW kPa m/h

Functions

Cooling

C&H

Heat Recovery

Characteristics
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents

Water flow Source side heat exchanger Pressure drop Water flow

0.77

1.12

1.46

1.75

2.08

2.39

2.79

3.39

4.32

5.18

kPa m/h L W H dB(A) kg


unit

8 0.43 610 600 850 56 92 38 37.1 39.5 4.4 2/2 6.8 8.9 42 6.38 0.62 610 600 850 56 96 50 50.5 54 4.3 2/2 9.2 12.4 38 8.68 0.8 610 600 850 56 110 56 56.4 61 4.5 2/2 9.9 13.6 40 9.7 0.95 610 600 850 56 120 65 64.7 72 4.6 2/2 11.6 15.6 43 11.13 1.13 610 600 850 58 130 75 75.3 84 4.7 2/2 13.5 18 45 12.95 1.32 610 600 850 58 140

12--18 1.47 610 600 850 61 150 90 90.4 105 4.5 4/4 16.2 23 40 15.5 1.81 880 730 1050 68 250 110 110 128 4.6 4/4 19.3 27.4 40 18.9 2.31 880 730 1050 68 280 130 130 152 4.7 4/4 22.8 32.4 42 22.4 2.57 880 730 1050 71 300 140 140 163.9 4.7 4/4 24.6 34.9 42 24

Structure

gas-liquid separator, high pressure switch and low pressure switch The heat pump units are complete also with 4-way valve and one way valve

Dimension (mm) Sound pressure level*** Net weight Model Nominal cooling capacity* Nominal heating capacity** COP Hermetic compressor Qty/circuit nr. Cooling power input* Heating power input** User side heat exchanger Pressure drop Water flow Source side heat exchanger Pressure drop Water flow Dimension (mm) Sound pressure level*** Net weight

Single phase rotary type (mod.05 to 07), single phase (mod. 08, 10, 12) and 3-phase (mod.08 to 140) scroll type compressors, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers

Hermetic compressor

Hydraulic circuit

Built with user side and source side water inlet/outlet connectors, water discharge connectors, air vent valve (mod.05 to 30 the user side is complete also with expansion vessel, water pump and flow switch. )

kW kW / Nr. kW kW kPa m/h

High efficiency plate type heat exchanger, factory insulated with flexible close cell material

Evaporator

Electric panel

High efficiency plate type heat exchanger, factory insulated with flexible close cell material

Condenser

Consists of: Compressor contactor Compressor protection breaker User side water pump contactor (for mod.05 to 30) User side water pump breaker (for mod.05 to 30) Microprocessor with function display

kPa m/h L W H dB(A) kg

60 7.55 880 730 1050 63 330

51 10.27 980 1010 1120 67 450

53 11.4 980 1010 1120 69 460

58 13.12 980 1010 1120 70 540

58 15.27 980 1010 1120 72 540

41 18.33 1750 900 1500 74 560

41 22.25 1750 900 1500 77 590

44 26.29 1750 900 1500 77 630

45 28.32 1750 900 1500 77 650

High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material

Desuperheater

Optional

Copper tube connection with charge valves, filter drier, thermostatic expansion valve (capillary for mod. 05 to 14),

Refrigerant circuit

Sight glass which must be installed in factory Source side flow switch Source side water pump Anti-vibration rubber Metallic filter for the water circuit Heat recovery exchanger Tube in tube heat exchanger

Performance values refer to the following conditions: * Source side water inlet/outlet 18oC/29oC, user side water inlet/outlet 12oC/7oC; ** Source side water inlet/outlet 13C/8C, user side water inlet/outlet 40C/45C; *** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.

14

15

Water Cooled Modular Scroll Chiller & Heat Pump


Cooling capacity from 90 to 160 kW Heating capacity from 82 to 168 kW

Nomenclature
L WW H R S C 90 D MM L: Lark air product Unit type WA: Water to Air WW: Water to Water C: Cooling only H: Heat pump Heat recovery type --: Without heat recovery R: With heat recovery Heat exchanger T: Tube in tube type P: Plate type S: Shell and tube type Refrigerant type --: R22 A: R410a B: R134a C: R407c Model Project condition D: Underground water loops --: Underground water Modular type MM: Modular master MS: Modular slave

Technical Data
Model unit kW kW kW m/h mm 90D 90 82 18.0 3.1 130D 130 125 26.0 4.5 160D 160 156 32.0 5.5 DN32 90 90 95 18.0 3.1 130 130 139 26.0 4.5 160 160 168 32.0 5.5

Water to Water Unit


Indoor installation Heat recovery rate: 20%-25%

Nominal cooling capacity* Nominal heating capacity** Heat recovery capacity Heat recovery water ow Heat recovery pipe connection Hermetic compressor Qty/refrigerant circuit Cooling power input*

Functions

Nr. kW kW

2/2 16.7 19.3

3/3 24.1 29.4

4/4 29.6 36.3

2/2 16.7 19.3

3/3 24.1 28.5

4/4 30.8 41.2

Cooling

C&H

Heat Recovery

Heating power input** Evaporator Pressure drop

kPa m/h mm

50 15.5

56 22.4

58 27.5 DN65

50 15.5

56 22.4

58 27.5

Characteristics
The master module can work independently or together with up to 7 slave modules, flexible design, stable performance, easy maintenance Reusable: using solar energy stored in earth as cooling & heating source Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents 3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers Shall and tube type evaporator, factory insulated with flexible close cell material Shall and tube dry expansion type condenser, factory insulated with flexible close cell material The refrigerant circuit is complete with filter drier, direct expansion valve, high and low pressure switch Acting as multi-function unit such as cooling, heating, with heat recovery function producing hot water for domestic use. LCD display as standard Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc

Water flow Connect pipe Condenser Pressure drop Water flow Connect pipe Overall dimensions for standard unit Length Width Height Overall dimensions for heat recovery unit Overall dimensions for standard unit Length Width Height RD type Net weight D type Net weight Sound pressure level***

kPa m/h mm

53 18.3

58 26.5

62 32.6 DN65

40 8.3

45 12.0

50 14.8

mm mm mm

2200 480 1380

2200 480 1380

2735 560 1400

2200 600 1480

2610 600 1480

3190 600 1480

Electric Panel

Consists of: Compressor breaker Compressor contactor Phase sequence relay Control circuit breaker Microprocessor with function display

mm mm mm kg kg dB(A)

2300 480 1380 760 680 76

2300 480 1380 920 830 76

2835 560 1400 1160 1080 76

2300 600 1480 760 680 76

2710 600 1480 920 830 76

3290 600 1480 1160 1080 76

Optional

Desuperheater as optional Electronic controller with BMS system Plate heat exchanger Sound insulation cabinet Channel steel basement

Performance values refer to the following conditions: * Source side water inlet/outlet temperature 18C/29C, user side water inlet/outlet temperature 12C/7C, for underground water; Source side water inlet/outlet temperature 25C/30C, user side water inlet/outlet temperature 12C/7C, for underground water loops; ** Source side water inlet/outlet temperature 15C/8C, user side water inlet/outlet temperature 40C/45C, for underground water; Source side water inlet/outlet temperature 8C/4C, user side water inlet/outlet temperature 40C/45C, for underground water loops; *** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a clear field.

16

17

Overall Dimensions

90 A B D E F G H 2200 1630 940 1380 480 1290 380

130 2200 1630 985 1380 480 1290 380

160 2735 2180 985 1400 560 1760 460

C90 2200 1630 980 1480 600 1290 480

C130 2610 2055 980 1480 600 1760 460

C160 3190 2635 980 1480 600 2250 460 A B D E F G H K

R90 2300 1630 940 1380 480 1290 380 375

R130 2300 1630 985 1380 480 1290 380 375

R160 2835 2180 985 1400 560 1760 460 385

RC90 2300 1630 1000 1480 600 1290 480 390

RC130 2710 2055 1000 1480 600 1760 460 400

RC160 3290 2635 1000 1480 600 2250 460 400

18

19

Water Cooled Screw Chiller


Cooling capacity from 140 to 1840 kW

Technical Data
Model Cooling capacity* Compressor Qty/refrigerant circuit Cooling power input* Energy adjustment steps Evaporator Water flow rate Water side pressure drop Condenser Water flow rate Water side pressure drop Desuperheater** Heating capacity Noise level*** Dimensions Length Width Height Net weight unit B140 B170 B220 B260 B310 B380 B480

kW Nr. kW step m3/h kPa m3/h kPa kW dB(A) mm mm mm kg

140 1/1 29 4 24 43 29 43 35 68 2850 1000 1530 1700

170 1/1 35.3 4 29 41 35 46 43 69 2960 1075 1525 1850

220 1/1 45.6 4 38 42 46 44 55 71 2970 1155 1550 2150

260 1/1 53.9 4 45 44 54 42 65 72 3240 1240 1620 2500

310 1/1 64.3 4 53 42 64 43 78 73 3250 1345 1800 3150

380 1/1 78.8 4 65 45 79 45 95 73 3340 1320 1800 3450

480 1/1 99.6 4 82 44 99 44 120 74 3290 1375 1995 3600

Water Cooled Screw Chiller


Indoor installation

Functions

Cooling

C&H

Heat Recovery
Model unit kW B530 530 B710 710 B900 900 B960 960 B1120 1120 B1470 1470 B1840 1840

Characteristics
14 sizes available ranging from 140 kW to 1840 kW cooling capacity Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc Semi-hermetic screw compressor for the whole range, each compressor is equipped with a crankcase heater and a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch Shell and tube dry expansion type condenser, factory insulated with flexible close cell material Shell and tube type evaporator The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display LCD display, touch screen control panel as standard Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions

Cooling capacity* Compressor Qty/refrigerant circuit Cooling power input* Energy adjustment steps Evaporator Water flow rate Water side pressure drop Condenser Water flow rate Water side pressure drop Desuperheater** Heating capacity Noise level*** Dimensions Length Width Height

Nr. kW step

1/1 110 4

2/2 147.3 8

2/2 186.7 8

2/2 199.2 8

4/4 232.4 Continues

4/4 305 Continues

4/4 381.7 Continues

m3/h kPa

91 43

122 45

154 43

165 42

192 44

252 46

315 47

m3/h kPa

110 44

147 42

186 45

199 41

232 46

304 45

381 45

Optional

Electronic expansion valve Desuperheater BMS system Plate heat exchanger Sound insulation cabinet Channel steel basement

kW dB(A)

133 76

178 78

225 78

240 79

280 79

368 81

460 81

mm mm mm kg

3530 1420 2055 3800

4150 1460 2020 5400

4550 1455 2090 6400

4650 1490 2190 7500

4320 2290 2210 8500

4650 2350 2365 11000

5000 2400 2465 12800

Nomenclature
L WW H R S B 530 L: Lark air product Unit type WA: Water to Air WW: Water to Water C: Cooling only H: Heat pump Heat recovery type --: Without heat recovery R: With heat recovery Heat exchanger T: Tube in tube type P: Plate type S: Shell and tube type Refrigerant type --: R22 A: R410a B: R134a C: R407c Model

Net weight

* Performance values refer to the following conditions: Condenser water inlet/outlet temperature: 30C/35C; Evaporator water inlet/outlet temperature: 12C/7C. ** Desuperheater is optional. *** Noise level measured in free field condition at distance of 1 meter.

20

21

Overall Dimensions
Mod. B140 B530 Mod. B1120 B1840

Model Model B140 B170 B220 B260 B310 B380 B480 B530 A 2850 2975 3025 3264 3268 3366 3188 3550 B 1000 1000 1155 1240 1341 1134 1360 1417 C 1445 1437 1545 1598 1798 1798 1988 2053 D 900 900 860 950 1020 1020 1100 1200 E 1450 1600 1600 1800 1900 1900 1850 2050 Model RB140 RB170 RB220 RB260 RB310 RB380 RB480 RB530 A 2850 2960 2970 3240 3250 3340 3290 3530 B 1040 1115 1195 1280 1385 1360 1414 1460 C 1570 1565 1590 1660 1840 1840 2035 2095 D 900 900 860 950 1020 1020 1100 1200 E 1450 1600 1600 1800 1900 1900 1850 2050 B1120 B1470 B1840

A 4320 4650 5000

B 2290 2350 2460

C 2210 2365 2465

D 2050 2110 2160

E 1160 1325 1500

F 2000 2000 2000

G 1160 1325 1500

Model RB1120 RB1470 RB1840

A 4320 4650 5000

B 2370 2430 2480

C 2290 2445 2545

D 2050 2110 2160

E 1160 1325 1500

F 2000 2000 2000

G 1160 1325 1500

Mod. B710 B960

Model B710 B900 B960

A 4145 4555 4645

B 1460 1455 1490

C 2020 2090 2190

D 1171 1171 1212

E 2965 3365 3465

Model RB710 RB900 RB960

A 4250 4550 4650

B 1540 1535 1570

C 2100 2170 2270

D 1171 1171 1212

E 2965 3365 3465

22

23

Ground Source Heat Pump


Cooling capacity from 140 to 1840 kW Heating capacity from 175 to 2300 kW

Technical Data
Ground Source Heat Pump
Indoor installation
Model Cooling capacity* Heating capacity* Compressor Qty/refrigerant circuit Cooling power input* Heating power input* Energy adjustment steps Evaporator Water flow rate in cooling* Water flow rate in heating* Water side pressure drop Condenser Water flow rate in cooling* Water flow rate in heating* Water side pressure drop Desuperheater** Heating capacity Noise level*** Dimensions Length Width Height Net weight Model Cooling capacity* Heating capacity* Compressor Qty/refrigerant circuit Cooling power input* Heating power input* Energy adjustment steps Evaporator Water flow rate in cooling* Water flow rate in heating* Water side pressure drop Condenser Water flow rate in cooling* Water flow rate in heating* Water side pressure drop Desuperheater** Heating capacity Noise level*** Dimensions Length Width Height Net weight unit kW kW Nr. kW kW step m3/h m3/h kPa m3/h m3/h kPa kW dB(A) mm mm mm kg unit kW kW Nr. kW kW step m3/h m3/h kPa m3/h m3/h kPa kW dB(A) mm mm mm kg 140 140 175 1/1 26.9 36.7 4 24 13 47 13 24 44 35 69 2850 1040 1570 1940 530 530 663 1/1 101.9 138.9 4 91 49 52 49 91 50 133 75 3530 1460 2095 4140 170 170 213 1/1 32.7 44.5 4 29 16 45 16 29 45 43 69 2960 1115 1565 2140 710 710 888 2/2 136.5 186.1 8 122 66 50 66 122 53 178 76 4150 1540 2100 5680 220 220 275 1/1 42.3 57.7 4 38 21 44 21 38 45 55 70 2970 1195 1590 2340 900 900 1125 2/2 173.1 235.8 8 155 84 53 84 155 52 225 78 4550 1535 2170 6680 260 260 325 1/1 50.0 68.1 4 45 24 45 24 45 46 65 70 3240 1280 1660 2880 960 960 1200 2/2 184.6 215.6 8 165 89 55 89 165 54 240 81 4650 1570 2270 7880 310 310 388 1/1 59.6 81.2 4 53 29 47 29 53 44 78 72 3250 1385 1840 3590 1120 1120 1400 4/4 215.4 293.5 Continues 193 104 53 104 193 51 280 81 4320 2370 2290 9050 380 380 475 1/1 73.1 99.6 4 66 65 45 35 65 46 95 73 3340 1360 1840 3790 1470 1470 1838 4/4 282.7 385.2 Continues 253 137 50 137 253 50 368 81 4650 2430 2445 11650 480 480 600 1/1 92.3 125.8 4 93 83 46 45 83 47 120 73 3290 1415 2035 3990 1840 1840 2300 4/4 353.8 482.2 Continues 316 171 54 171 316 54 460 81 5000 2480 2545 13050

Functions

Cooling

C&H

Heat Recovery

Characteristics
14 sizes available ranging from 140 kW to 1840 kW cooling capacity Reusable: using solar energy stored in earth as cooling & heating source Great environmental and economic benefit: no boiler or cooling tower; less space, less CO2 and less initial investment Acting as multi-function unit such as cooling, heating, sanitary hot water separately or simultaneously Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc Semi-hermetic screw compressor for the whole range. Each compressor is equipped with a crankcase heater and a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line. The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch Shell and tube dry expansion type condenser, factory insulated with flexible close cell material Shell and tube type evaporator, factory insulated with flexible close cell material The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display LCD display, touch screen control panel as standard Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions

Optional

Electronic expansion valve Desuperheater as optional Electronic controller with BMS system Plate heat exchanger Sound insulation cabinet Channel steel basement

Nomenclature
L WW H R S B 530 L: Lark air product Unit type WA: Water to Air WW: Water to Water C: Cooling only H: Heat pump Heat recovery type --: Without heat recovery R: With heat recovery Heat exchanger T: Tube in tube type P: Plate type S: Shell and tube type Refrigerant type --: R22 A: R410a B: R134a C: R407c Model

* Performance values refer to the following conditions: Cooling: condenser water inlet/outlet temperature: 18C/29C, evaporator water inlet/outlet temperature: 12C/7C. Heating: condenser water inlet/outlet temperature: 40C/45C, evaporator water inlet/outlet temperature: 15C/10C. ** Desuperheater is optional. *** Noise level measured in free field condition at distance of 1 meter.

24

25

Overall Dimensions
Mod. B140 B530 Mod. B1120 B1840

Model
Model B140 B170 B220 B260 B310 B380 B480 B530 A 2850 2975 3025 3264 3268 3366 3188 3550 B 1000 1000 1155 1240 1341 1341 1360 1417 C 1445 1437 1545 1598 1798 1798 1988 2053 D 900 900 860 950 1020 1020 1100 1200 E 1450 1600 1600 1800 1900 1900 1850 2050 Model RB140 RB170 RB220 RB260 RB310 RB380 RB480 RB530 A 2850 2960 2970 3240 3250 3340 3290 3530 B 1040 1115 1195 1280 1385 1360 1415 1460 C 1570 1565 1590 1660 1840 1840 2035 2059 D 900 900 860 950 1020 1020 1100 1200 E 1450 1600 1600 1800 1900 1900 1850 2050

A 4320 4650 5000

B 2290 2350 2460

C 2210 2365 2465

D 2050 2110 2160

E 1160 1325 1500

F 2000 2000 2000

G 1160 1325 1500

Model RB1120 RB1470 RB1840

A 4320 4650 5000

B 2370 2430 2480

C 2290 2445 2545

D 2050 2110 2160

E 1160 1325 1500

F 2000 2000 2000

G 1160 1325 1500

B1120 B1470 B1840

Mod. B710 B960

Model B710 B900 B960

A 4145 4555 4645

B 1460 1455 1490

C 2020 2090 2190

D 1171 1171 1212

E 2965 3365 3465

Model RB710 RB900 RB960

A 4150 4550 4650

B 1540 1535 1570

C 2100 2170 2270

D 1171 1171 1212

E 2965 3365 3465

26

27

Fan Coil Unit (Water Chilled)


Air Flow: 340-2380m3/h

2 ROWS
Model Item
Air flow (m3/h) Cooling capacity Heating capacity Input power (W) High Mid Low W W 12Pa 30Pa 50Pa 12Pa 30Pa 50Pa type quantity material

3.4
410 340 260 2050 3480 33 40 49 37 38 41 1 metal 6 360 10 13

5.1
550 450 350 2820 4700 32 54 65 36 39 43 2 metal 8 480 16 14.5

6.8
750 600 470 3740 6260 60 72 84 39 43 45 2 metal 11 660 26 16.5

8.5
900 730 560 4500 7500 82 92 105 43 45 47

10.2

13.6

17.0
1800 1480 1120 8300 13830 152 180 210 48 48 51 4 metal 24 1440 32 29

20.4
2110 1730 1360 10350 17250 189 215 248 49 49 52 4 metal 30 1800 40 33

23.8
2700 2210 1750 11510 19190 250 280 310 51 51 52 4 metal 33 1980 38 39

Noise level dB(A)

Fan Water flow (L/min) Water flow (L/h) Pressure drop (kPa) Net weight (kg) Coil Connection dim. Condensing water

Characteristics
Frame and structure
Panels and frame are made from galvanized steel, properly punched and punched for fixing both accessories and the unit itself polyester powder coating to ensure total resistance to atmospheric agents

connecting outlet Terminal block placement

1060 1500 820 1230 640 950 5230 7500 8720 12490 94 134 112 156 122 184 45 46 46 47 49 50 Centrifugal type 2 2 3 metal metal metal 13 15 21.5 780 900 1290 16 22 28 17.8 19 26.5 2 rows/1.6MPa 3/4 (inner grooved) DN20 steel pipe 9.52 welding copper pipe Other side of water inlet/outlet

Filter
The easily removable filter is made of filtering honeycomb polypropylene fabric and supported by an aluminum frame. The filter is installed on the units with plenum only

Heating coil
The coils are made from seamless tubes expanded into aluminum fins in continuous block. The connections have brass headers with female fittings and provided with easily accessible vent and drainage valve

3 ROWS
Model Item
Air flow (m3/h) Cooling capacity Heating capacity Input power (W) High Mid Low W W 12Pa 30Pa 50Pa 12Pa 30Pa 50Pa type quantity material

3.4
340 280 220 2300 3905 32 41 48 37 38 41 1 metal 6.6 396 14 14

5.1
510 420 330 3200 5330 31 52 63 36 39 43 2 metal 9 540 25 15.6

6.8
680 560 440 4250 7080 58 65 82 39 42 45 2 metal 12.3 738 20 17.7

8.5
850 690 540 4720 7870 76 87 100 43 45 47

10.2

13.6

17.0

20.4
2040 1670 1300 11600 18640 180 210 236 49 49 51 4 metal 33 1980 40 35.3

23.8
2380 1950 1540 13000 21290 208 250 290 49 50 51 4 metal 37 2220 47 41.5

Electric connection box


All electric wires are connected to enclosed electrical terminal block, situated on the same side of the water connections

Fan deck
The fan decks are composed of double suction centrifugal fans with aluminum impellers and 3-speed fan motors. Each fan motor assembly is dynamically balanced

Optional

Drip tray

On-board thermostat and remote thermostat Electric heater Return air box Balancing valve

Noise level dB(A)

The drip trays are made from sheet metal treated with
Fan

Nomenclature
L FP N E F B 5.1 M

Lark air product Fan coil Installation method L: With supporting legs N: Without supporting legs Unit version C: Concealed version E: Exposed version with plastic covers

Air intake F: Front air intake O: Underside air intake Coil type A: 2 pipe 2 rows B: 2 pipe 3 rows C: 2 pipe 4 rows D: 4 pipe 2+1 rows E: 4 pipe 3+1 rows

Air flow External static pressure --: Standard (12Pa) M: Medium static pressure (30Pa) H: High static pressure (50Pa)

Water flow (L/min) Water flow (L/h) Pressure drop (kPa) Net weight(kg) Coil Connection dim. Condensing water

connecting outlet Terminal block placement

1020 1360 1700 830 1100 1390 660 850 1080 5900 8150 9460 9840 13570 15490 91 130 150 106 150 172 118 174 205 45 46 48 46 47 48 49 50 51 Centrifugal type 2 2 3 4 metal metal metal metal 13.8 17 23.5 27 828 1020 1410 1620 24 35 35 40 19.1 20.5 28.3 31 3 rows/1.6MPa 3/4 (inner grooved) DN20 steel pipe 9.52 welding copper pipe Other side of water inlet/outlet

1. High speed with pressure. 2. Cooling capacity: water inlet 7 , difference in temperature 5 , DB27/WB19.5 ; Heating capacity: water inlet 60 , DB21 .

28

29