You are on page 1of 5

Rolling Stock Questions

1. The work of MVSI is checked from corridor no --------- in WAG 5 loco. 2. -----------lamp glows if CCQV 61 melted. 3. The length of OHE is ------------------m on main line. 4. Setting of QD -1 is ---------amp in WAG 7. 5. Braking resistance are cooled by ---------------blower during rehostatic braking. 6. Upto ---------mm.wheel skiding in wagon is permisable to work the train at normal speed. 7. Cut in pressure of RGCP is -----------kg/cm2 8. The setting of QPDJ is ---------Amp. 9. Wedging of ---------------relay is prohibited in rear loco of MU. 10. Max. pressure of SMGR must be ---------kg/ cm2 11. -----------relay gets deenergise while RS open. 12. -------------switches are kept on '0' for 6th notch testing. 13. Battery voltage can be checked by ---------------. 14. PHGR starts working on ----------------notches. 15. Cab FAN gets supply of -------------- volts.

16. ZPT has ---------------- positions. 17. Pick up voltage of Q 20 is --------------volts in WAG 7. 18. CTF coil gets suplly from -------------fuse . 19. WAP4 has ------------------nos shunting contactors. 20. VE-1 & VE-2 are fitted inside of ------------21. QLM relay may be reset for ---------------times. 22. DJ will tripped by------------ relay, if MP kept on '0' and GR doesnot come to '0' 23. -------------fuse is removed, if AFL circuit gets defective. 24. After applying A9, BP pressure drops through-------------valve in train 25. In case of over voltage Auto regration takes place by _______ relay. 26. -----------Relay gets deenergised if GR stucked up between notches. 27. -------------type of contactor is provided for starting Arno. 28. Auto regression will take place through ---------------relay, if DJ trips 29. Max. speed-----------------during manual operation of GR 30. Min. brake power percentage should be ------------------% in Goods train. 31. ------------pressure drops while ACP.

32. C2A31 to be charge _________ pressure. 33. During MU operation, open the switch --------------- to deenergise the trailing loco. 34. TS switch is used to check the work of ---------------35. To check oil level of compressor, --------- must be open. 36. Continuous current rating of WAP 4 loco is ----------Amp. 37. Section is to be cleared with ---------------amp.if MPH isolated in WAG 5. 38. ---------------contactor is closed when MP kept on 'P'. 39. The setting of QLM in WAP 4 loco is ----------Amp. 40. Flasher light will works on ___________ volts supply. 41. RS pressure will not maintain if -------------cock kept closed 42. Position of MU2B valve in leading loco is ---------43. Loco brake applied by ----------valve, if SA 9 applied 44. current sould not be exceed beyond ------------Amp. In field coil during rehostatic braking. 45. WAG-5 loco has _______ no. center pivots. 46. Vacuum on dummy should be --------mm in WAG 5 loco.

47. ----------valve gets energise if OHE triped while rehostatic braking. 48. --------------will not glow if CCLS melted. 49. EVPHGR terminals are removed if --------------fuse melt on 6th notch. 50. ----------fuse is provided for protection of BA from over current. 51. -------- ----valve gets energise when MP kept on 'P' 52. DJ will tripped if OHE voltage dropped below ------------ kV . 53. VESA gets supply from -------------fuse. 54. The length of PTFE Neutral section is -------------------m . 55. The charging time of single pipe train is ________ Min. 56. To apply Hand brake, the handle is operated ---------------------times. 57. -------------lamp will glow, if CHBA not working. 58. Feed valve gets pressure of MR 2 through -----------59. Max. BC pressure of wagon is ------kg/cm2 if BP pressure drops 1.6 kg /cm2

60. The setting of HS 4 is -----------kg/cm2 . 61. The use of ----------is restricted if Q 50 is wedged.

62. The continuous permissible current rating of WAG-5 loco is _______Amp. if one TM of each block is isolated. 63. ----------relay gets energise while HBA 'ON'. 64. MU2B kept on ________ position in Dead Loco. 65. Stagger on main line is -------------mm. 66. Arno convertor output voltage is -------- volt 67. -----------relay gets energise by SWC switch. 68. -------------blower cools the X-mer oil.

You might also like