You are on page 1of 18

VSL

Appendix Technical Data & Dimensions

Multistrand Post-Tensioning

Bonded Slab Post-Tensioning

2 - 11

12 - 14
1

Monostrand Post-Tensioning

External Post-Tensioning

Ground Anchors

15

16 - 17

18

Multistrand Post - Tensioning

VSL

Strand Properties
Strand Type

13 mm (0.5'')

15 mm (0.6'')

Strand Type
N
S
Nominal diameter mm
12.5
12.9
Nominal area
mm 2
93
100
Tensile strength
MPa
1,860
1,860
Min. breaking load
kN
173
186
195 approx.
Young's modulus
GPa
max 2.5
Relaxation
%
The above values are indicative, and the regional standards must be applied.

N
15.2
140
1,860
260

S
15.7
150
1,860
279

Tendon Properties
Strands Type 0.5''

Number
of strands
per
tendon
u
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Strands Type 0.5'' N


1,860 MPa
Area of
Minimum
the tendon breaking load
2
mm
kN
173
93
346
186
519
279
692
372
865
465
1,038
558
1,211
651
1,384
744
1,557
837
1,730
930
1,903
1,023
2,076
1,116
2,249
1,209
2,422
1,302
2,595
1,395
2,768
1,488
2,941
1,581
3,114
1,674
3,287
1,767
3,460
1,860
3,633
1,953
3,806
2,046
3,979
2,139
4,152
2,232
4,325
2,325
4,498
2,418
4,671
2,511
4,844
2,604
5,017
2,697
5,190
2,790
5,363
2,883
5,536
2,976
5,709
3,069
5,882
3,162
6,055
3,255
6,228
3,348
6,401
3,441
6,574
3,534
6,747
3,627
6,920
3,720
7,093
3,813
7,266
3,906
7,439
3,999
7,612
4,092
7,785
4,185
7,958
4,278
8,131
4,371
8,304
4,464
8,477
4,557
8,650
4,650
8,823
4,743
8,996
4,836
9,169
4,929
9,342
5,022
9,515
5,115

Strands Type 0.5'' S


1,860 MPa
Area of
Minimum
the tendon breaking load
2
mm
kN
186
100
372
200
558
300
744
400
930
500
1,116
600
1,302
700
1,488
800
1,674
900
1,860
1,000
2,046
1,100
2,232
1,200
2,418
1,300
2,604
1,400
2,790
1,500
2,976
1,600
3,162
1,700
3,348
1,800
3,534
1,900
3,720
2,000
3,906
2,100
4,092
2,200
4,278
2,300
4,464
2,400
4,650
2,500
4,836
2,600
5,022
2,700
5,208
2,800
5,394
2,900
5,580
3,000
5,766
3,100
5,952
3,200
6,138
3,300
6,324
3,400
6,510
3,500
6,696
3,600
6,882
3,700
7,068
3,800
7,254
3,900
7,440
4,000
7,626
4,100
7,812
4,200
7,998
4,300
8,184
4,400
8,370
4,500
8,556
4,600
8,742
4,700
8,928
4,800
9,114
4,900
9,300
5,000
9,486
5,100
9,672
5,200
9,858
5,300
10,044
5,400
10,230
5,500

Strands Type 0.6''


Number
of strands
per
tendon
u
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Strands Type 0.6'' N


1,860 MPa
Area of
Minimum
the tendon breaking load
2
mm
kN
260
140
520
280
780
420
1,040
560
1,300
700
1,560
840
1,820
980
2,080
1,120
2,340
1,260
2,600
1,400
2,860
1,540
3,120
1,680
3,380
1,820
3,640
1,960
3,900
2,100
4,160
2,240
4,420
2,380
4,680
2,520
4,940
2,660
5,200
2,800
5,460
2,940
5,720
3,080
5,980
3,220
6,240
3,360
6,500
3,500
6,760
3,640
7,020
3,780
7,280
3,920
7,540
4,060
7,800
4,200
8,060
4,340
8,320
4,480
8,580
4,620
8,840
4,760
9,100
4,900
9,360
5,040
9,620
5,180
9,880
5,320
10,140
5,460
10,400
5,600
10,660
5,740
10,920
5,880
11,180
6,020
11,440
6,160
11,700
6,300
11,960
6,440
12,220
6,580
12,480
6,720
12,740
6,860
13,000
7,000
13,260
7,140
13,520
7,280
13,780
7,420
14,040
7,560
14,300
7,700

Strands Type 0.6'' S


1,860 MPa
Area of
Minimum
the tendon breaking load
2
mm
kN
150
279
300
558
450
837
600
1,116
750
1,395
900
1,674
1,050
1,953
1,200
2,232
1,350
2,511
1,500
2,790
1,650
3,069
1,800
3,348
1,950
3,627
2,100
3,906
2,250
4,185
2,400
4,464
2,550
4,743
2,700
5,022
2,850
5,301
3,000
5,580
3,150
5,859
3,300
6,138
3,450
6,417
3,600
6,696
3,750
6,975
3,900
7,254
4,050
7,533
4,200
7,812
4,350
8,091
4,500
8,370
4,650
8,649
4,800
8,928
4,950
9,207
5,100
9,486
5,250
9,765
5,400
10,044
5,550
10,323
5,700
10,602
5,850
10,881
6,000
11,160
6,150
11,439
6,300
11,718
6,450
11,997
6,600
12,276
6,750
12,555
6,900
12,834
7,050
13,113
7,200
13,392
7,350
13,671
7,500
13,950
7,650
14,229
7,800
14,508
7,950
14,787
8,100
15,066
8,250
15,345

Multistrand Post - Tensioning

VSL

Stressing Anchorage VSL Type CS 2000


C

F1 resp. F2
E

J1 resp J2

K
30

Pxt stirrups or equivalent orthogonal reinforcement

X = Anchorage spacing
X r = Clearance to edge

Stressing Anchorage VSL Type CS 2000


Tendon
Unit
6-7
6-12
6-19
6-27
6-31
6-37

222
258
300
360
390
420

60
80
90
110
122
130

50
60
70
70
70
82

143
178
210
256
274
300

1)

50
55
60
30
30
30

F1

F2

400
500
540
660
620
805

535
638
660
810
740
925

250
325
420
520
555
610

J1

J2

275
62/69
59/73
385
76/83
76/91
450
90/97 100/116
495 115/122 115/131
540 125/132 130/146
600 125/132 130/146

12
16
16
18
20
22

5
7
9
9
9
10

295
370
470
575
610
665

55
55
50
55
60
60

12
12
16
18
18
18

5
7
9
9
9
10

315
390
490
595
630
685

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cube), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
F1: valid for CS STANDARD, F2 valid for CS PLUS and CS SUPER.
J1: standard inner/outer diameter of corrugated steel duct.
J2: standard inner/outer diameter of PT Plus duct.
n: number of spiral turns.
X: anchorage spacing, minimum clearance to edge Xc = 0.5*X + cover.
1) When diameter G too small to clear "nose" of bearing plate, set spiral back (i.e. E + 30mm).

Multistrand Post - Tensioning

VSL

Stressing Anchorage VSL Type Ec

X= Anchorage spacing

Strand
Type 0.5''

Tendon Unit
5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

Dimensions
A
120
135
165
215
270
290
340
370
395
430

B
130
125
155
215
285
335
365
360
380
460

C
50
50
55
60
75
85
95
105
110
130

D
90
95
110
150
180
190
230
240
260
290

E
50
55
74
104
135
150
172
188
201
230

F
35/40
40/45
50/57
65/72
80/87
85/92
100/107
120/127
130/137
140/150

G
145
160
200
270
350
370
440
480
510
550

Strand
Type 0.6''

6-3
135
125
50
95
55
40/45
160
6-4
150
155
55
110
65
45/50
200
6-7
190
170
60
135
84
60/67
250
6-12
250
245
75
170
118
80/87
330
6-19
310
305
95
200
150
100/107
400
6-22
340
365
100
220
178
110/117
430
6-31
390
350
120
260
192
130/137
510
6-37
430
450
135
280
215
140/150
550
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
J: diameter of spiral steels.
n: number of spiral turns.
X: according to a0 of the French approval.

J
10
10
12
14
16
18
20
22
22
22

n
3
3
4
5
6
6
7
7
8
9

X
145
160
200
270
350
370
440
480
510
550

145
210
260
345
440
480
540
605

10
12
14
16
18
18
22
22

3
4
5
6
7
8
8
9

160
200
250
330
400
430
510
550

Stressing Anchorage VSL Type E

X= Anchorage spacing

Strand
Type 0.5''

Tendon Unit
5-1
5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

Dimensions
A
70
120
140
180
250
300
330
400
420
450
520

B
10
15
20
25
35
45
50
60
65
60
75

C
45
50
50
55
60
75
85
95
105
110
130

D
42
90
95
110
150
180
190
230
240
260
290

E
15
50
55
74
104
135
150
172
188
201
230

F
60
175
170
165
205
355
430
490
505
530
605

G
80
145
170
230
310
395
430
500
550
590
680

H
90
135
150
200
275
330
360
420
455
490
560

6-1
80
10
50
53
18
60
100
100
6-2
120
15
50
90
50
175
145
150
6-3
150
25
50
95
56
165
185
150
6-4
170
25
55
110
65
165
215
200
6-7
220
35
60
135
84
155
290
250
6-12
300
45
75
170
118
325
380
330
6-19
370
55
95
200
150
475
480
420
6-22
400
60
100
220
172
590
520
420
6-31
470
75
120
260
192
615
620
520
6-37
520
80
135
280
215
750
680
585
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
K: diameter of spiral steels.
n: number of spiral turns.
X: according to a0 of the French approval.
Strand
Type 0.6''

H
145
145
210
285
345
380
440
475
540
605

J
25/30
40/45
45/50
55/60
65/72
80/87
85/92
100/107
120/127
130/137
140/150

K
8
10
10
12
14
16
18
18
20
22
22

n
2.5
3.5
3.5
4.5
5.5
6.5
6.5
7.5
7.5
7.5
8.5

X
80
145
170
230
310
395
430
500
550
590
680

30/35
40/45
45/50
50/55
60/67
80/87
95/102
110/117
130/137
140/150

8
10
10
12
14
16
18
18
20
22

2.5
3.5
3.5
4.5
5.5
6.5
7.5
7.5
8.5
9.5

100
145
185
215
290
380
480
520
660
680

Multistrand Post - Tensioning

VSL

Coupler VSL Type K

Coupler VSL Type K


A

Strand
Type 0.5''

5-3
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

430
550
650
740
830
1,140
1,320
1,290
1,370

140
140
140
140
140
140
180
180
200

40
60
60
80
90
90
120
130
150

130
170
200
240
260
350
390
395
420

Strand
Type 0.6''

Tendon Unit

6-2
6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

380
490
520
630
730
860
930
1,090
1,390

150
160
160
160
160
160
160
180
200

30
60
60
70
80
90
90
130
130

140
150
160
190
240
280
310
360
430

Dimensions in mm.
For concrete strength, stressing, and spacing, please refer to anchorages types Ec or E.

Coupler VSL Type V

Coupler VSL Type V


E

Strand
Type 0.5''

5-3
5-7
5-12
5-19
5-22
5-31

275
400
420
560
630
940

205
205
205
205
205
205

220
260
320
455
520
600

30
60
60
80
90
90

140
180
210
240
260
350

Strand
Type 0.6''

Tendon Unit

6-2
6-3
6-4
6-7
6-12
6-19

160
260
290
400
500
630

215
225
225
225
225
225

200
210
210
220
410
580

30
60
60
70
80
90

150
160
170
200
250
290

Dimensions in mm.

Multistrand Post - Tensioning

VSL

Dead-End Anchorage VSL Type H

Dead-End Anchorage VSL Type H


Tendon Unit
5-3
5-4
5-7

6
Strand
Type 0.5''

5-12
5-19
5-22
5-31
5-37
5-42
5-55

Strand
Type 0.6''

6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

Alternative

Type

1
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
1
2
3

I
I
I
II
II
II
I
II
II
II
II
II
II
II
II
II
II
II
II
II
II

230
310
150
370
170
350
310
470
310
570
390
670
470
770
470
870
670
570
1,170
870
570

70
70
170
70
190
190
270
190
390
190
390
310
430
310
550
350
430
550
350
430
670

930
930
930
1,280
1,280
1,280
1,280
1,280
1,280
1,280
1,280
1,480
1,480
1,680
1,680
1,680
1,680
1,680
1,980
1,980
1,980

180
180
200
200
230
230
300
300
350
350
350
350
400
400
400
400
400
400

155
155
155
155
155
155
155
155
155
155
165
165
165
165
165
185
185
185

12
12
14
14
14
14
16
16
16
16
18
18
18
18
18
20
20
20

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1
1
2
1
2
1
2
1
2
1
2
1
2
1
2

I
I
I
II
II
II
I
II
II
II
II
II
II
II
II

290
390
190
450
210
430
390
570
390
690
470
810
570
1,050
690

90
90
210
90
230
230
330
230
470
230
490
260
510
370
510

950
950
950
1,300
1,300
1,300
1,300
1,300
1,300
1,300
1,300
1,700
1,700
2,000
2,000

200
200
230
230
300
300
350
350
400
400
400
400

155
155
155
155
155
155
155
155
165
165
185
185

14
14
14
14
16
16
16
16
18
18
20
20

7
7
7
7
7
7
7
7
7
7
7
7

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
n: number of spiral turns.

Multistrand Post - Tensioning

VSL

Dead-End Anchorage VSL Type P

Dead-End Anchorage VSL Type P


A

Strand
Type 0.5''

5-1
5-3
5-7
5-12
5-19
5-22
5-31

120
230
230
230
230
230
230

60
70
140
210
350
350
350

300
350
400
500
600
800

130
190
220
260
260
260

100
150
180
180
180

188
262
264
316
316
316

8
12
12
14
16
16

4
4
5
5
5
5

Strand
Type 0.6''

Tendon Unit

6-1
6-2
6-3
6-4
6-7
6-12
6-19

130
230
230
230
230
230
230

80
60
100
100
185
280
470

250
300
350
400
500
700

130
190
190
220
260
260

100
150
150
150
180
180

188
262
262
264
316
316

8
12
12
14
16
16

4
4
4
5
5
5

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
n: number of spiral turns.

Multistrand Post - Tensioning

VSL

Intermediate Anchorage VSL Type Z

Intermediate Anchorage VSL Type Z


Strand
Type 0.5''

5-2
5-4
5-6
5-12
5-22

1)

Strand
Type 0.6''

Tendon Unit

6-2
6-4
6-6
6-12
6-22

1)

1)

1)

2)

2)

130
160
200
280
350

60
70
90
140
170

80
90
130
140
200

60
65
85
90
120

400
500
600
1,000
1,450

560
720
890
1,440
2,070

170
200
240
320
390

140
170
210
300
400

70
80
100
160
190

90
100
140
160
250

65
70
90
100
145

450
900
1,000
1,350
1,500

620
1,130
1,320
1,910
2,290

180
210
250
340
440

Dimensions in mm.
1) Tension ring only on side 2.
2) Dependent upon the shape of the concrete surface.
The values stated apply for surfaces which are not curved.

Dead-End Anchorage VSL Type ZU

Intermediate Anchorage VSL Type ZU


Tendon Unit
Strand
Type 0.5''

5-2
5-4
5-6

1)

Strand
Type 0.6''

6-2
6-4
6-6

1)

1)

1)

165
165
165
170
170
200

2)

2)

103
103
113

80
88
95

60
65
70

450
600
650

655
835
925

200
200
220

105
105
120

90
92
105

65
65
75

450
560
650

700
815
930

210
220
240

Dimensions in mm.
1) Tension ring only on side 2.
2) Dependent upon the shape of the concrete surface.
The values stated apply for surfaces which are not curved.

Multistrand Post - Tensioning

VSL

Dead-End Anchorage VSL Type L

Dead-End Anchorage VSL Type L


Strand
Type 0.5''

Tendon Unit
5-4
5-7
5-12
5-19
5-22
5-31

A Int/ext

B Int/ext

R min.

50/55
65/72
80/87
90/97
95/102
110/117

45/50
55/60
65/72
80/87
85/92
100/107

600
600
900
1,100
1,200
1,400

Strand
Type 0.6''

6-2
600
50/55
45/50
6-3
600
50/55
45/50
6-4
600
55/60
50/55
6-7
750
75/82
60/67
6-12
1,000
90/97
80/87
6-19
1,300
100/117
95/102
Dimensions in mm.
Dimensions are valid for nominal concrete strength:
28 MPa (cube), 23 MPa (cylinder), at the time
of stressing, for a maximum stressing force
of 80% of the tendon breaking load.

Dead-End Anchorage VSL Type AF


9
F

2nd injection

Overflow of
1st.injection

1st.injection
X = Anchorage spacing
X r = Clearance to edge
A

Dead-End Anchorage VSL Type AF for vertical tendons


Tendon Unit

6-12
6-19
6-22
6-31

265
315
325
375

700
700
750
900

60
60
60
60

460
460
510
660

90
90
90
90

95/102
120/127
130/137
150/157

380
480
520
620

450
540
600
660

16
18
18
20

9
9
10
11

60
60
70
80

410
510
550
650

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
Maximum prestressing force (80% of minimum tendon breaking load) may be applied when mortar of first injection in the
AF anchor reaches 100 MPa (cube).
n: number of spiral turns or ortogonal stirrups.
X: anchorage spacing, minimum clearance to edge Xc = 0.5*X + cover.

Multistrand Post - Tensioning

VSL

Ducts PT-PLUSTM System

Type

Unit
0,5
5-12
5-19
5-31
5-37
5-55

59
76
100
115
130
150

0,6
6-7
6-12
6-19/22
6-27
6-31/37
6-43

58
76
100
115
130
150

63
81
106
121
136
157

73
91
116
131
146
167

2.5
2.5
3.0
3.0
3.0
3.5

42.0
52.5
60.0
60.0
52.0
60.0

82
100
123
138
153
174

108
116
126
127
134
127

106
124
147
162
177
198

Dimensions in mm.

10

Corrugated Steel Ducts


Sizes of the Ducts and Eccentricity of the
Centre of Gravity of Strands

Duct

Eccentricity

Tendon unit

Dia. of Duct
int/ext

Eccentricity

Tendon unit

Dia. of Duct
int/ext

Eccentricity

5-1
5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

20/25
35/40
40/45
50/57
65/72
80/87
85/92
100/107
120/127
130/137
140/150

4
7
7
8
11
13
12
14
23
26
23

6-1
6-2
6-3
6-4
6-7
6-12
6-19
6-31
6-37

25/30
35/40
40/45
45/50
60/67
80/87
100/107
130/137
140/150

5
6
6
6
10
14
17
22
25

Dimensions in mm.

Dimensions in mm.

Multistrand Post - Tensioning

VSL

Block Out Dimensions and Clearance Requirement


Jack Type A min.
ZPE-23FJ
ZPE-30
ZPE-3
ZPE-60
ZPE-7A
ZPE-12St2
ZPE-200
ZPE-19
ZPE-460/31
ZPE-500
ZPE-750
ZPE-1000
ZPE-1250
Dimensions in mm.

30
30
30
30
50
50
50
60
80
80
80
90

300
600
550
650
800
700
1,100
850
700
1,150
1,350
1,300
1,350

1,200
1,100
1,000
1,100
1,200
1,300
2,100
1,500
1,500
2,000
2,300
2,200
2,250

116
140
200
180
300
310
330
390
485
585
570
790
660

90
100
150
140
200
200
210
250
300
330
365
450
375

11

Stressing Jack Data

Type I (ZPE-23FJ)
Designation
Type
Length
(mm)
Diameter
(mm)
Stroke
(mm)
Piston area (cm2)
Capacity
(kN)
Pressure
(bar)
Weight
(kg)
Used for 13 mm
(0.5'') tendon types
Used for 15 mm
(0.6'') tendon types

Type II (ZPE-19)

ZPE-23FJ ZPE-30
I
790
116
200
47.1
230
488
23
5-1

III
720
140
250
58.32
320
549
28
5-1

6-1

6-1

Type III (ZPE-500)

ZPE-3

ZPE-60

ZPE-7A ZPE-12St2 ZPE-200

ZPE-19 ZPE-460/31 ZPE-500 ZPE-750 ZPE-1000 ZPE-1250

III
475
200
160
103.6
500
483
47
5-2
5-3
6-2

III
615
180
250
126.4
632
500
74
5-2
to 5-4
6-2
6-3

III
690
280
160
203.6
1,064
523
115
5-6
5-7
6-4

II
750
390
100
500.3
2,900
580
294
5-18
5-19
6-12

II
550
310
100
309.4
1,850
598
151
5-12

III
960
315
300
325.7
2,000
614
305
5-12

6-6
6-7

6-6
6-7

II
580
485
100
804
4,660
580
435
5-22
5-31
6-18
6-19

III
II
III
II
1,000
1,185
1,200
1,290
550
520
790
620
200
150
200
150
894.6 1,247.00 1,809.50 2,168.00
5,000
7,500 10,000 12,500
559
601
553
577
1,064
1,100
2,290
1,730
5-22
5-31
5-37
5-37
5-31
5-37
to 5-55 to 5-55
6-18
6-31
6-31
6-31
to 6-22
to 6-43 to 6-55

Bonded Slab Post - Tensioning System

VSL

Stressing Anchorage VSL Type SO


X = Anchorage spacing
XR = Clearance to edge
_ + required cover to reinforcement
XR = X
2

Grout tube

The details of the reinforcement in the anchorage zone


should be determined by the engineer of record.
The arrangement shown here is common for slabs in buildings.

Detail of reinforcement

General slab
reinforcement

12

Type

H1)

Kmin

Lmin2)

306
SO 5-4
144
250
96
65
103
K-30
75
110 1.5 x K
330
SO 6-4
168
280
115
75
127
K-30
75
120 1.5 x K
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
1) Use actual K when calculating H.
2) L shall be the maximum permitted by the slab thickness and cover, whereas Lmin = 1.5 x K.

10
12

14
16

370
400

Dimensions of Ducts
Tendon unit

18

21

72

75

0.3

21

35

72

86

2.0

5-4
Steel Duct
Polyethylene
Duct
PT-PLUSTM
Dimensions in mm.

6-4
5-4
6-4

Bonded Slab Post - Tensioning System

VSL

Dead-End Anchorages VSL Type H and Type P


Type H

Type

70
H 5-4
310
90
H 6-4
390
Dimensions in mm.
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

930
950

Type P

13
Type

65
H 5-4
230
80
H 6-4
260
Dimensions in mm.
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

360
430

Coupler VSL Type SK

Type

SK 5-4
SK 6-4

408
510

150
330

140
150

170
220

Dimensions in mm.
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Bonded Slab Post - Tensioning System


Stressing Jack Clearance Requirements

Jack Type
ZPE-23FJ
DKP-5
DKP-6

Tendon unit

A (mm)

B (mm)

C (mm)

5-4

1,100

260

280

6-4
5-4
6-4

1,100
1,000
1,200

260
260
400

300
270
300

Stressing Jack Data

14

Jack Type
A
B
C
D
Stroke
Piston area
Capacity
Pressure
Weight

ZPE-23FJ
(mm)
(mm)
(mm)
(mm)
(mm)
(cm2)
(kN)
(bar)
(kg)

DKP-5

790
116

560
162
105
150
200
31.03
147
473
19

195
200
47.10
230
488
23

Typical Recess

DKP-6
615
240
84
165
200
49.26
230
467
30

VSL

Monostrand Post - Tensioning System

VSL

Stressing Anchorage VSL Type S-6


*

* for 20-mm cover, to be adjusted for other values as needed.


Dimensions in mm.
Dimensions are valid for nominal concrete strength: 24 MPa (cube), 20 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Dead-End Anchorage VSL Type SF-6


15

Dimensions in mm.
Dimensions are valid for nominal concrete strength: 24 MPa (cube), 20 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Coupler VSL Type SK-6

Dimensions in mm.
Dimensions are valid for nominal concrete strength: 24 MPa (cube), 20 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

External Post - Tensioning System

VSL

Stressing Anchorage VSL Type E

2)

Mmin

80
120
150
170
220
300
370
400
470
520

18
50
56
65
84
118
150
172
192
215

10
15
25
25
35
45
55
60
75
80

53
90
95
110
135
170
200
220
260
280

50
50
50
55
60
75
95
100
120
135

80
80
80
85
90
105
125
130
150
165

100
145
185
215
290
380
480
520
620
680

100
150
150
200
250
330
420
420
520
585

8
10
10
12
14
16
18
18
20
22

50
50
50
50
50
55
60
60
65
65

2.5
3.5
3.5
4.5
5.5
6.5
7.5
7.5
8.5
9.5

70
190
190
190
190
370
530
650
690
830

P
position and diameter according
to the grout material

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
1) Bearing plate also made of cast iron.
2) L: number of spiral turns if the last spiral turn is welded, or L + 1 if the last spiral is opened.

Stressing Anchorage VSL Type Ec

Tendon Unit

Strand
Type 0.6''

16

6-1
6-2
6-3
6-4
6-7
6-12
6-19 1)
6-22
6-31 1)
6-37 1)

Dimensions
according to the material
and dimensions of the duct

Strand
Type 0.6''

Tendon Unit

6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

Dimensions
A

135
150
190
250
310
340
390
430

95
110
135
170
200
220
260
280

65
77
96
115
135
135
165
175

100
115
145
190
235
255
295
320

125
155
170
245
305
365
350
450

50
55
60
75
95
100
120
135

80
85
90
105
125
130
150
165

50
60
55
60
65
67
70
80

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
1) L: number of spiral turns.

1)

3
4
5
6
7
8
8
9

160
200
250
330
400
430
510
550

145
210
260
345
440
480
540
605

10
12
14
16
18
18
22
22

45
50
50
55
60
60
65
65

External Post - Tensioning System

VSL

Stressing Anchorage VSL Type Ed

Strand
Type 0.6''

Tendon Unit
6-7
6-12
6-19
6-31
6-37

Dimensions
A

250
310
390
430
520

245
305
350
450
530

60
65
70
80
90

175
225
275
305
320

95
115
145
155
183

75
90
110
125
140

190
235
295
320
420

100
115
135
160
170

45
45
45
55
55

345
235
540
605
745

16
18
22
22
26

55
60
65
65
80

330
400
510
550
640

6
7
8
9
9

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
Special anchorage permitting easy tendon replacement.
1) N: number of spiral turns.

17

Stressing Anchorage VSL Type Edm

BMIN

80
120
150
170
220
300
370
400
470
520

35
155
155
145
145
325
485
605
635
775

10
15
25
25
35
45
55
60
75
80

35
35
35
45
45
45
45
45
55
55

according to the dimensions of


the opening at the anchorage

according to the material and


dimensions of the duct

6-1
6-2
6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

Dimensions
according to the dimensions
of the work at the anchorage

Strand
Type 0.6''

Tendon Unit

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
Special anchorage permitting easy tendon replacement..
Spirals: according to the dimensions of the opening at the anchorage.

1)

Ground Anchors

VSL

VSL Permanent Anchors (K1)


Number
of strands
13 mm
(0.5)

Ultimate
capacity based
on 0.5S strand

Weight
of
strands

Cross sectional
area

Diameter of anchors
GA
without Pi
(mm)
85
85
95
115
125

RA without Pi,
GA with Pi
(mm)
90
90
100
120
130

GA
with Pi
(mm)
95
95
105
125
135

(kN)
(kg / m)
(mm2)
3
558
2.4
300
4
744
3.1
400
7
1,302
5.5
700
12
2,232
9.4
1,200
19
3,534
14.9
1,900
Data for anchors with higher capacity on request
Dimensions are same for ASTM A 416 strands, with respective ultimate capacity.
Drill hole diameter is approx. 20 mm bigger than anchor diameter, but need to be confirmed by local drilling company.
For dimensions of anchorages and other data please contact your local VSL office.
- K1 :
Permanent Anchor.
- GA:
Ground Anchor.
- RA :
Rock Anchor.
- Pi :
Post-Injection.

VSL Temporary Anchors (K2 and K3)


18
Number
of strands
13 mm
(0.5)
3
4
7
12
19
Data for

Ultimate
capacity based
on 0.5S strand

Weight
of
strands

(kN)
(kg / m)
558
2.4
744
3.1
1,302
5.5
2,232
9.4
3,534
14.9
anchors with higher capacity on request
K2:
with external spacer for thick grout cover.
K3:
without external spacer.

Cross sectional
area
(mm2)
300
400
700
1,200
1,900

VSL Extractable Anchors


Number
of strands
15 mm
(0.6)

Ultimate
capacity based
on 0.6S strand

Test
load

Max. diameter of anchors


with or without post-injection
Type K2
(mm)

Type K3
(mm)

83
83
90
99
119

48
48
64
74
84

(extractability of free length)


Weight
of
strands

Cross sectional
area

Max.
diameter
of anchor

(kN)
(kN)
(kg / m)
(mm2)
(mm)
2
379
323
2.4
300
90
3
568
485
3.5
450
90
4
758
647
4.7
600
90
5
948
808
5.9
750
90
6
1,137
970
7.1
900
100
7
1,327
1,132
8.2
1,050
100
Data for anchors with higher capacity on request
Dimensions are same for ASTM A 416 strands, with respective ultimate capacity.
Drill hole diameter is approx. 20 mm bigger than anchor diameter, but need to be confirmed by local drilling company.
For dimensions of anchorages and other data please contact your local VSL office.
Please note reduced strands ultimate capacity to permit extractability.