You are on page 1of 33

A Interface Integration with MML

BSS S14

Nokia Siemens Networks

RN28173EN13GLN0

A Interface Integration
This module describes the A interface signalling hierarchy and traffic channel distribution within the BSC. Following this module you should be able to use the BSS Integration reference material to create an A interface connection as detailed below:

Connecting the A interface ET Creating the transcoder devices Creating the MTP Creating the SCCP Creating the speech channels

Nokia Siemens Networks

RN28173EN13GLN0

A interface configuration

A Interface

MSC
TCSM

BSC

1 FR 2 FR 3 FR 4 FR 1 HR 2 HR 3 HR 4 HR 5 HR 6 HR 7 HR

Highway PCM

GSWS

Highway PCM

Nokia Siemens Networks

RN28173EN13GLN0

Steps to integrate the A interface


Start

Connect the A interface ET Create the transcoder unit

Create the MTP Create the SCCP and BSSAP CCS7 signalling

Create the speech channel

End

Nokia Siemens Networks

RN28173EN13GLN0

Connect the A interface ET


Start no

PIU exists?

Create ET plug-in unit

yes
ET connected to the right IF

no

Connect ET

yes

Check ET settings and change them if necessary

Change working state End

Nokia Siemens Networks

RN28173EN13GLN0

Identify connected ET-Interface


< ZWUP:32&40&96; LOADING PROGRAM VERSION 18.10-0 EXECUTION STARTED BSC3i BSC11 2005-04-21 10:03:36 1

PCM COMP PROC INFO_1 INFO_2 INFO_3 ADD_INFO PAGE 32 BCSU SC7PRB ETPCM VIRTUAL_PCMS 33H 01B1H 0000H 0000H 0100H 1280 40 BCSU ERATES ETPCM 33H 010AH 0000H 0000H 0000H 96 BCSU ABIPRB ETPCM VIRTUAL_PCMS 30H 01BFH 0000H 0000H 0000H 1792 - 1799 TOTAL OF 3 PCM CIRCUITS

Nokia Siemens Networks

RN28173EN13GLN0

Steps to create the TCSM2 unit


Start

Rack exists?

no

Create transcoder rack

yes Create cartridges for ETs and TCSM

Create functional unit for ET and TCSM Create plug-in units for ETs, TR16s and TRCO Connect ETs and TRCO Change TCSM working state yes

TCSM used for CCS7 or X.25

Add through connections

no End

Nokia Siemens Networks

RN28173EN13GLN0

TCSM2 rack and cartridges


ET indexes and tracks: (higher part) ETs 0 and 1: track 0 ETs 2 and 3: track 1 ETs 4 and 5: track 2 ETs 6 and 7: track 3 ET indexes and tracks: (lower part) ETs 0 and 1: track 4 ETs 2 and 3: track 5 ETs 4 and 5: track 6 ETs 6 and 7: track 7 Coordinates of the cartridges ET 0: nnc 120-01 ET 1: nnc 120-13 ET 2: nnc 120-49 ET 3: nnc 120-61 TC1C 0: nnc 088-01 TC1C 1: nnc 088-37 TC1C 2: nnc 058-01 TC1C 3: nnc 058-37 TC1C 4: nnc 030-01 TC1C 5: nnc 030-37 TC1C 6: nnc 002-01 TC1C 7: nnc 002-37 nn=row c = rack

ET1TC
E T 2 E tracks: 0 E T 2 E tracks: 4 E T 2 E 1 E T 2 E 5 E T 2 E 2 E T 2 E 6 E T 2 E 3 E T 2 E 7

TCSM2
POWER INPUT BLOCK

(TCSM2 0) (TCSM2 2) (TCSM2 4) (TCSM2 6) (TCSM2 3) (TCSM2 5) (TCSM2 7) (TCSM2 1)

TC1C 0
TCSM2 0

TC1C 1
TCSM2 1

TC1C 2
TCSM2 2

TC1C 3
TCSM2 3

TC1C TC1C 4
T T T T TT T T T TT R R R R R R R R R RR C1 1 1 1 1 1 1 1 1 1 0 6 66 66 6 6 6 6 6 T R 1 6 T R 1 6 T R 1 6 T R 1 6 P S C 1
TCSM2 4

TC1C 5
TCSM2 5

TC1C 6
TCSM2 6

TC1C 7
TCSM2 7

tracks:

0 1 2 3 4 5 6 7 8 910 11121314 15
RN28173EN13GLN0

Nokia Siemens Networks

Steps to create the TCSM3i unit


Start

Cabinet exists?

no

Create transcoder cabinet

yes Create cartridges for ETs, cabinet clock and TR3

Create TCSM functional unit Create plug-in units : ETs in ET16, TR3 and CL3TG Connect TR3 to BSC Change TCSM working state yes

TCSM used for CCS7?

Add through connections

no End

Nokia Siemens Networks

RN28173EN13GLN0

Stand-Alone TCSM3i
1 3 5 7 9 11 2 4 6 8 10 12

10 9

11

12 11

10

Nokia Siemens Networks

RN28173EN13GLN0

Standalone TCSM3i
Indexes

Ater IF ETs
ETC0 ETC1 ETC2

1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_81_2_3_4_5_6_7_8

15

246 8

37

A IF ETs
TC2C-0
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16

TC2C-1

9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8

Only 1 BSC can be connected because of 1 Ater ET piu

2 BSCs can be connected because there are 2 ATER pius

1_2_3_45_6_7_8 9_10_11_12 13_14_15_16


11 Nokia Siemens Networks RN28173EN13GLN0

13_14_15_16 9_10_11_12 1_2_3_45_6_7_8

Standalone TCSM3i
Indexes

ETC0

ETC1

ETC2

1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_81_2_3_4_5_6_7_8

1 5 9 13

2 4 6 8 1012 14 16

3 7 11 15

TC2C-2
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16

TC2C-3

9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8

Only 1 BSC can be connected because of 1 Ater ET piu

10

11

12

13

14

15

16

2 BSCs can be connected because there are 2 ATER pius

1_2_3_45_6_7_8 13_14_15_16 9_10_11_12


12 Nokia Siemens Networks RN28173EN13GLN0

13_14_15_16 9_10_11_12 1_2_3_45_6_7_8

Standalone TCSM3i
Indexes

ETC0

ETC1

ETC2

1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_81_2_3_4_5_6_7_8

1 5 9 13 1719 2123

2 4 6 8 1012 14 16

3 7 11 15 18 202224

TC2C-4
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16

TC2C-5

9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8

Only 1 BSC can be connected because of 1 Ater ET piu

17

18

19

20

21

22

23

24

2 BSCs can be connected because there are 2 ATER pius

1_2_3_4 5_6_7_89_10_11_12 13_14_15_16

13_14_15_16 1_2_3_4 5_6_7_89_10_11_12

13

Nokia Siemens Networks

RN28173EN13GLN0

Standalone TCSM3i
TR3E/TR3A/TR3T roles when using ETIP
For standalone TCSM3i user can use ET16 or ETIP for Ater and A
interface. If ETIP using ETIP, the role of TR3E/TR3A/TR3T will slightly changed as follow:

* acts as a cartridge master when two BSCs are connected to one cartridge

14

Nokia Siemens Networks

RN28173EN13GLN0

Three layers of CCS7 signalling

MSC
BSSAP SCCP MTP

BSC
BSSAP SCCP

TCSM

MTP

15

Nokia Siemens Networks

RN28173EN13GLN0

Creating MTP and adding signalling link


Start Create signalling link
MTP exists?

Yes

Create signalling point code Create signalling link set including sign. link Add signalling link to link set

Create signalling route set


Allow activation of signalling link Allow activation of signalling route Change signalling link state Change route set state Change signalling link state Allow activation of signalling link

End
16 Nokia Siemens Networks RN28173EN13GLN0

MTP layer

MSC 3 SPC=1234

MSC 1 SPC=1233
e.g. TS 31 SLC=0 e.g. TS 31 SLC=1

e.g. TS 16

MSC 2 SPC=1235 Signalling Link Set Signalling Route Set

Signalling Link

BSC

SPC=1223

17

Nokia Siemens Networks

RN28173EN13GLN0

Creating of SCCP and the subsystem BSSAP


Start
Create service for CONS (10F) and CLNS (208)

Create local SCCP and local Subsystem BSSAP (FE)

Create remote SCCP and local Subsystem BSSAP (FE)

Modify broadcast status of SCCP signalling points

Modify local broadcast status of SCCP subsystems Change local and remote SCCP state

Change local and remote Subsystem state

End

18

Nokia Siemens Networks

RN28173EN13GLN0

BSS Application Part: BSSMAP and DTAP

BSSMAP: BSS Management Application Part DTAP: Direct Transfer Application Part

BSSAP BSSAP
BSSMAP DTAP

SCCP

SCCP

MS

MTP
MSC TCSM BSC

MTP
BTS

19

Nokia Siemens Networks

RN28173EN13GLN0

Creating speech channels


Start
yes

Circuit group exists?

no Create a circuit group

Add circuits to the circuit group Change the state of the speech circuits

End

20

Nokia Siemens Networks

RN28173EN13GLN0

Speech circuits

BSC
GSWB

MSC
NCGR=MSC01 TCPCM-1 ET-36 ETPCM-36

TCSM

TCPCM-2 TCPCM-3

21

Nokia Siemens Networks

RN28173EN13GLN0

Exercise: A interface integration

MSC

CCS7 in TSL16

BSC
SPC=............. CCS7 in TSL....... Link set=.............. SLC=...... Sign. network=........ ET.....

Codec= SPC=............. CCSPCM=...... CGR=........

TCSM......

22

Nokia Siemens Networks

RN28173EN13GLN0

A Interface using SIGTRAN protocol stack


BSC
MSC

BSSAP SCCP M3UA


Sigtran

BSSAP SCCP M3UA SCTP


IP

SCTP
IP

Ethernet

Ethernet

23

Nokia Siemens Networks

RN28173EN13GLN0

Sigtran - Signalling over IP


Sigtran defines a standardized way of carrying any SS7 signalling
over IP networks Defines retransmission and reordering functionalities Physical layer can be any layer 1 technology

Sigtran signalling stack

Application
Signalling adaptation Transport layer Physical layer
24 Nokia Siemens Networks RN28173EN13GLN0

M3UA
SCTP IP Ethernet/SDH/etc .

Application can be ISUP, BICC, SCCP, etc.

Stream Control Transmission Protocol ( SCTP)


Services by SCTP: Application provides reliable data transfer between two IP end points

It offers acknowledged error-free nonduplicated transfer of datagrams (messages).


Detection of data corruption, loss of data and duplication of data is achieved by using checksums and sequence numbers. A selective retransmission mechanism is applied to correct loss or corruption of data.

SCTP

IP

L2 L1

25

Nokia Siemens Networks

RN28173EN13GLN0

M3UA MTP3 User Adaptation


Different adaptation layers possible - M2UA (MTP2 user adaptation layer) - M3UA (MTP3 user adaptation layer) - SUA (SCCP user adaptation layer) M3UA supported in the 1st implementation of Rel4 M3UA (MTP3 User Adaptation) provides MTP3 user adaptation for upper layers to use
MAP TCAP MAP TCAP SUA SCTP IP

SCCP
M3UA SCTP IP

26

Nokia Siemens Networks

RN28173EN13GLN0

Sigtran Terms and Concepts


DX200
Signalling point A
MSC (Server)
CCSU_0 CCSU_1 CCSU_2

Addressing based on SPCs!


Signalling point B

Association Set (up to 16 associations)


SCTP Association
BSC (Client)
BCSU_0

IP

BCSU_1 BCSU_2

CM

MCMU

SPC_1

IP Addresses

SPC_2

Signaling Link Set can only contain one "Sigtran link". "Sigtran link" consists of one SCTP association set. Association is identified by the computer unit and destination address. Only one association allowed per computer unit.
27 Nokia Siemens Networks RN28173EN13GLN0

Sigtran Terms and Concepts

28

Nokia Siemens Networks

RN28173EN13GLN0

Sigtran Terms and Concepts

29

Nokia Siemens Networks

RN28173EN13GLN0

Steps of creating A-IF SIGTRAN in BSC


1. 2. 3. 4.

5.
6. 7. 8. 9.

10.
11. 12. 13. 14. 15. 16. 17.

Create IP network interface for BCSU Create an SCTP parameter set for SIGTRAN Create an association set Add associations to association set Configure association IP Configure source IP address for SCTP Check associations Modify associations if needed Create Signalling Link Set and IP signalling link Create Signalling Route Set Allow and activate IP signalling link Allow and activate signalling route Create SCCP service Create local SCCP & Subsystem Create remote SCCP & subsystem Activate Local & Remote SCCP Activate Local & Remote SCCP subsystem

( ZQRN) ( ZOYE) ( ZOYC) ( ZOYA) ( ZOYP) ( ZOYN) ( ZOYI ) ( ZOYM) ( ZNSP ) ( ZNRC ) ( ZNLA&ZNLC ) ( ZNVA & ZNVC ) ( ZNPC ) ( ZNFD ) ( ZNFD ) ( ZNGC ) ( ZNHC )

30

Nokia Siemens Networks

RN28173EN13GLN0

Ater Connection to MGW

31

Nokia Siemens Networks

RN28173EN13GLN0

Ater IF to MGW

MGW implements the same base transcoding functionality and

features as TCSM2.
MGW doesnt support 8kbit/s submultiplexing on Ater No O&M LAPD between BSC and MGW. No need to equip TCSM unit into BSC HW database User is responsible for creating identical transcoder configurations to both BSC and MGW.

32

Nokia Siemens Networks

RN28173EN13GLN0

Step Create Ater IF to MGW in BSC:


Create ET Connect ET to A-IF Activate ET Set number of through connected channels Create TC-PCM ( ZWTU, ZWTP) ( ZWUC ) ( ZUSC ) ( ZWGS ) ( ZWGC)

1. 2.

3.
4. 5.

33

Nokia Siemens Networks

RN28173EN13GLN0