You are on page 1of 41

Ventilation with Heat Recovery Dee Fly Single Detached Housing

July 2007

Ventilation with Heat Recovery Dee Fly Single Detached Housing HRV - Principle
The air renewal is guaranteed mechanically with air supply into the main rooms and air exhaust from the sanitary areas and the kitchen thanks to a ductwork and grilles. Thanks to the heat exchanger 90% of the calories of the exhausted air are used to preheat the supplied air.

Ventilation with Heat Recovery Dee Fly Single Detached Housing HRV- Principle

Ventilation with Heat Recovery Dee Fly Single Detached Housing Heat Exchanger Principle
The heat exchange is done through the plates.

Fresh air Exhaust air

Exchanger plates

Ventilation with Heat Recovery Dee Fly Single Detached Housing Heat Exchanger Principle
Cross-flow exchanger, efficiency ~ 70%
Outdoor air = 0C Air exhaust = 20C

Air discharge = 6C

Air supply = 14C

Ventilation with Heat Recovery Dee Fly Single Detached Housing Heat Exchanger Principle
Counter-flow exchanger, efficiency > 90%
Outdoor air = 0C Air exhaust = 20C

Air discharge = 2C

Air supply = 18C

Ventilation with Heat Recovery Dee Fly Single Detached Housing Heat Exchanger Principle
The global efficiency of the heat exchanger is linked to :
The airflow The exchange area The space between the plates The humidity level (condensation, up to +10% efficiency) Temperatures
=
TC air supply - TC fresh air TC air exhaust - TC fresh air

Ventilation with Heat Recovery Dee Fly Single Detached Housing The System
1
5 4

Ventilation with Heat Recovery Dee Fly Single Detached Housing The System
Motorisation Exchanger RCC 160/125+ Algaine D125 Minigaine Ductwork Flat repartition box

Control (kitchen)

BAP Supply grille

BIP

Ventilation with Heat Recovery Dee Fly Single Detached Housing Ductwork in Heated Area
Use of the Minigaine ductwork
Integration in false ceiling
Control of the pressure losses Easy maintenance

Use of the flat repartition box


Connection with minigaine
Integration in false ceiling H < 100 mm

Ventilation with Heat Recovery Dee Fly Single Detached Housing Ductwork in Non Heated Area
Use of the insulated algaine
Insulated after the exchanger only
Be careful to the pressure losses and to the installation

Use of the repartition box in PPE


Make the connection easier Insulation material
14-Dperditions conduits DF MI.XLS

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflow Regulation
Supply
Global regulation of the supply airflow thanks to the micro-watt motor

Exhaust
Regulation in the sanitary areas thanks to the selfbalanced grilles Self airflow amplifier in the kitchen

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflow Regulation
Minigaine 60x200 Minigaine 40x100

Bouche dextraction BAP dans les sanitaires


Auto-amplificateur 125 mm sur bouche cuisine

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflow balancing
Adjustable cover just behind the grille And/or Drilled damper in the ductwork with less pressure losses

Ventilation with Heat Recovery Dee Fly Single Detached Housing Speed selection
V1 : Basic airflow V2 : Peak airflow for the kitchen Timer 30 min Supply airflow balancing V3 : BOOST = 300 m3/h Without timer Kitchen + Supply Ideal for the air quality or the summer comfort with Geothermal Temperation

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflow Regulation thanks to the Motor
Airflow selection according to the quantity of sanitary areas The motor adjusts its speed to guarantee this airflow Limitation of the motor couple to avoid an overconsumption

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflow Regulation thanks to the Motor

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflow Regulation thanks to the Motor
Selection thanks to a switch behind the control keyboard

Ventilation with Heat Recovery Dee Fly Single Detached Housing By-pass version
Addition of an intermediate piece on the heat exchanger Control of the by-pass light switched off : close light blue : open

Ventilation with Heat Recovery Dee Fly Single Detached Housing


Non micro-watt version (Dee Fly 70)
2 speeds available Basic airflow Peak airflow for the kitchen

Regulation of the supply airflow thanks to a self airflow amplifier

Ventilation with Heat Recovery Dee Fly Single Detached Housing Filtration
G4 filters on the heat exchanger Filter unit on the fresh air as option (G4)

Ventilation with Heat Recovery Dee Fly Single Detached Housing Airflows and Power Consumption
Dee Fly 70

Ventilation with Heat Recovery Dee Fly Single Detached Housing Thermal efficiceny

Conditions : TC air extrait = 25C/13C BH / TC air neuf = 5C/0C BH

Ventilation with Heat Recovery Dee Fly Single Detached Housing Installation
In-line Allows the installation of the motor in the attics Makes the integration of the heat exchanger in the heated area easier

Ventilation with Heat Recovery Dee Fly Single Detached Housing Installation
Put together

Ventilation with Heat Recovery Dee Fly Single Detached Housing Installation
Boiler assembly Makes the installation in a cellar easier Connections on the top side

Ventilation with Heat Recovery Dee Fly Single Detached Housing


The Condensates
In the winter the heat exchange between a cold airflow and a hot and humid airflow causes the development of condensation It is necessary to evacuate it Connection for condensate evacuation integrated in the Dee Fly casing for each type of installation

Ventilation with Heat Recovery Dee Fly Single Detached Housing The Condensates
Ceiling installation Evacuation from the bottom side

Ventilation with Heat Recovery Dee Fly Single Detached Housing The Condensates
Installation on the floor Addition of a piece to protect the evacuation and guarantee the tightness

Ventilation with Heat Recovery Dee Fly Single Detached Housing The Condensates
Hoizontal installation on the wall Addition of a water recuperation tray Evacuation from the bottom side

Ventilation with Heat Recovery Dee Fly Single Detached Housing The Defrosting
Risk of condensates frosting when the outdoor temperature < 0C When using micro-watt version,decrease of the fresh airflow to facilitate the defrosting When using the standard version, use of an electrical coil integrated in the motor casing

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Why to require the new HRV ALDES ?

Ventilation with Heat Recovery Dee Fly Single Detached Housing

The comfort power 3


Indoor air quality :
Filtered fresh air = healthier and less dirty

Thermal comfort :
Winter : Heat recovery => nos cold draft and comfort temperature maintained in the housing Summer comfort : Possiblity to associate the Dee Fly with a buried well to refresh the fresh air (Geothermal Temperation)

Sound insulation :
No air inlets in the facade = total sound insulation / outdoor.

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Energy savings and and Ecology


Up to 20% decrease of the heating consumption * :
With limitating the losses linked to the air renewal Dee Fly allows to realize savings (up to 200 / year)

Ecological ventilation :
Dee Fly recovers the energy from the exhaust air. Used in association with a buried well: Dee Fly uses the geothermal energy of the ground to refresh the air during the summer time. (avoids the use of air conditioning)

Low consumption motorisation micro-watt :


New technology of motors which allows a low power consumption
* In regards to a self-balanced CMEV according to the French standard of calculation

Ventilation with Heat Recovery Dee Fly Single Detached Housing

A modular system
1 motorisation casing + 1 exchanger casing = All the installations possibles
Separated / Put together Floor / ceiling Horizontal / Vertical

>> Easier integration >> Adaptability >> Exchanger in heated area = efficiency

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Directional air supply grille


Directional Adjustable (cover) Design
>> Wall/Ceiling installation >> Comfort of the air jet (summer / winter) >> Discreet integration

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Speed selection
V1 : basic airflow V2 : peak airflow in the kitchen, 30 min timer V3 : BOOST Function maxi 300 m3/h without timer,
>> Air quality comfort according to the demand >> Air speed higher in the summer >> Efficiency for the geothermal Temperation >> Supplied and exhausted airflows balanced

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Installation
Ceiling : Threaded rod + mountings

Floor : Feet sold as accessory

>> Duct connections thanks to quick and airtight connection collars. Patented system in 160 mm

Ventilation with Heat Recovery Dee Fly Single Detached Housing

The Range
Dee Fly micro-watt 90 Dee Fly micro-watt 90 + by-pass Dee Fly 70 Dee Fly 70 + by-pass

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Codification / accessories
Supply accessories set 5 grilles
5 grilles BIO (new grille when available) 5 elbows for grilles

Additional supply set 1 grille


1 grille BIO (new grille when available) 1 elbow for grille

Ventilation with Heat Recovery Dee Fly Single Detached Housing

Codification / accessories
Exhaust accessories set Kitchen + 2 sanitary areas
1 BIP + self amplifier 125 2 BAP 30 m3/h 3 elbows for grilles

Additional sanitary area


BAP