You are on page 1of 32

CONSTRUCTION OF HIGH LEVEL BRIDGE OVER SUTLEJ RIVER

WELL FOUNDATION

PROJECT BREIFING
This bridge forms a part of a bye-pass project near Ropar

The project is undertaken by B&R division of PWD. Total cost of the bridge over Sutlej is 63 crs. The contract is given to the company on the lump sum basis.
Length
Lanes Spans Length of span

982 m
4 lane 28 36.5 m ( middle 23 spans) 24 m (end spans)

Formation level
High flood level

273.5 m
264.2 m

Alignment
Alignment of the

bridge passes through : New I.I.T. Road Sutlej river

Nwansheher highway
Alignment crosses river

at an angle therefore it is a Skew alignment

Height of Bridge
Bridge is high level bridge i.e. formation

level is above H.F.L. Height if bridge is determined by examining the clearance of bridge over highway As per IRC 5:1998 Min. clearance needed = 5 m Road level =267 Width of beam and slab =1.7 m Req. formation level= 273.7 m Actual formation level=274.7 m

Extent of exploration
The exploration shall cover the entire length of the bridge and also

extend at either side for a distance of about twice the depth below bed of the last main foundations i.e. if depth of foundation below bed is 24mts. then exploration will be done up to 48mts away from ends.
The depth of exploration should be at least 1 times the minimum

width of the foundation below the proposed foundation level in case of open foundations and deep well foundation
Where such investigation end in any unsuitable or questionable foundation

material, the exploration shall be extended to a sufficient depth into firm and stable soil or rock but not less than four times the minimum depth of foundation below the earlier contemplated foundation level.

Scour depth
Depth of scour below the high flood level.

Scour depth has important in determination depth of

foundation. Determination The maximum depth of scour should be measured with reference to existing structures near the proposed bridge site, if this is possible. Such soundings are best done during or immediately after a flood. Mean scour depth (dsm )= 9.2 m Max. scour depth for piers = 2 dsm = 18.4 m

Depth of foundation
Well foundation are taken up to depth such that min.

grip of foundation below max. scour depth is 1/3 rd of max. scour depth. The max. Bearing pressure on the subsoil under the foundation resulting from any combination of the loads and forces except wind and seismic forces should not exceed the safe bearing capacity of the subsoil, after taking into account the effect of scour.

WELL FOUNDATION
Well foundation lies

under the category of open caisson


They are open at both

ends

Well Components
Cutting edge Well curb Well steining Bottom plug Sand fill Top plug Well cap

Cutting edge
Cutting edge is the lowermost part of a well It is the part which cuts through the earth. The mild steel cutting edge shall be made from structural steel sections. The cutting edge shall weigh not less than 40 kg per metre length and be properly anchored into the well curb sections are bent into shape by cold bended no heating is done.

The picture above shows a three 160mm MS Sections curved and welded to form Cutting Edge.

Well curb
Well curb is a structure with outer wall of curb being straight and inner at an appropriate angle which is fabricated over cutting edge. The internal angle of curb can be kept between 30O to 37o . It serves the purpose of transferring Load from steining to bottom plug. Thickness of well curb is 75mm more than that of steining to prevent tilts

A fabricated well curb set atop wooden planks

Well curb

Reinforcements in a well curb

Vertical bars -20 dia. Triangular bars -20 dia.

Well steining
It is the longest part of well and it transfers load from

1.

2. 3.

well cap to the well curb at desired depth. Track of length is taken by marking wells on 4 sides by gauges. Steining is built in lifts of 2.15m and each lift is aligned with previous one. As per IRC 78:200 The amount of vertical reinforcement provided should not be less than .2% of cross sectional area of steining. At the inner face reinforcement must not be less than .06% of area. Transverse reinforcement must not be less than .04% of volume/unit length of steining.

Reinforcements in steining

For wells 12 to 23 Outer dia.= 5.35 m inner dia. = 3.4 m Area of steining= 13.394 Min. reinforcement for steining (20 dia. Bars)= .02*area/area of bar = 85.3 = 86 bars Actual no. =62+26 =88 bars Min. reinforcements for inner wall(20 dia.)=.oo6*area/area of bar =25.59 = 26 bars Actual no. =26 bars

Well steining
Determination of thickness of steining
The min. thickness should not be less than 500mm and should be

according:

h=kdl

where : h- min. thickness in m d=external dia. Of well l=depth of well below well cap k= a constant = 0.03

At the site:

avg. depth of well = 25m dia. = 5.2m

So

Min. thickness required = .78 m

Well steining
But some adjustments are needed in thickness according to

the strata as given by the table:


Strata Very soft clay strata Adjustment -10%

Hard clay strata


Boulder strata or well resting on rock

+10%
+10%

As the strata is sand with boulders

final thickness is = .858 m Original thickness =.78 m (well no. 1-11 and 24 -29) = .88m (well no. 12-23)

Bottom plug- transfers the load of structure from well to the

ground. It is cast under water after the final depth of well is reached. No reinforcement is provided. The mix should have min. cement content of 330Kg/m3 laying of bottom plug. It helps in increasing the weight of the foundation which provides more stability to the structure. It also counteract buoyant force of water. filling sandwiched & undisturbed. The concrete used for intermediate plugging is also M25.

Sand filling : Sand filling shall commence after a period of 3 days of

Intermediate plug :The function of the plug is to keep the sand

Top plug :After filling sand up to the required level a plug of

concrete is provided over it as shown on the drawing. It at least serves as a shuttering for laying well cap. pier to the well or wells below. It is designed as two way slab.

Well cap- It is needed to transfer the loads and moments from the

Well parameters
Parameters Data 59 n0. 1. 2. Total no. of wells to be sunk M 30 Grade of concrete used for well curb and steinning: M 25 OPC 43-G 3. Grade of concrete used for bottom, intermediate and top plugging

4.
5. 7. 9.

Type of Cement used


FE 500 Grade of steel used for reinforcement: 9m Scouring levels from previous years data: 16 mm Thickness of the cutting edge:

Well parameters
Parameters Depth of the wells below ground: Data Well no. 1 to 11:24.0 m Well no. 12 to 23: 26.5 m Well no. 24 to 29: 24.0 m Height of well curb: well no. 1 to 11 and 24,25: 1.410 m Well no. 12 to 25: 1.530

Thickness of the well steinning:

Well no. 1 to 11: 780 mm


Well no. 12 to 23: 880 mm Well no. 24 to 29: 780 mm

Construction of well

Setting of well curb


Sinking of well Bottom plugging

Sand filling
Closing of top by well cap

Setting of well curb


The centre of the well is marked

accurately with help of theodolite. Cutting edge is placed on the wooden sleepers such that centre of cutting edge coincide with the marked centre. Reinforcements and formwork for curb is fabricated on the cutting edge and concreting is done. After curing of well curb is complete the wooden slippers below the curb are removed by making soil below them diluted by water and is allowed to sink under its own weight.

In this picture a well curb is resting on the wooden slippers

Sinking of well/Construction of steinning

3. Dredging of earth to support sinking

1. Fabrication of formwork and reinforcements

2. Concreting

Sinking of Well
Fabrication of Formwork
Fabrication
The formwork for

Concreting

casting are supported on the channels bolted with steining on both sides. As per design lap is provided after every fourth reinforcement at same section.

Concreting is done by pumping the concrete to the mould by concrete pump. The concrete is placed in 400mm thick layers along with continues vibrations. On avg. about 23m3 of concrete is needed for casting of one lift.

Sinking of Well
Dredging In order to sink the well, continuous dredging is done. Soil is excavated from the dredge hole inside the well. The dredging operation is performed evenly along the hole circular hole

Construction of well
Bottom plugging : it is done after the well

has reached the founding level. Concreting is done inside water. For this tremie pipe is used. A tremie is long funnel made of mild steel . A flap door is provided at its bottom. Well cap:After water filling, a truss system consisting of three trusses supported in well steining and cribs welded with it in criss-cross manner are used for top plugging. This system is covered with strong plywood and sealed with concrete slurry so that nothing can enter inside the well. Hence preparing it for the casting of well cap.

Methods to promote sinking


Kentledge -Total of 125 concrete cubes of 1m3 in size

are made for kentledge loading which is approximately equal to 25t 125. Chiseling- When the boulders are very firmly cemented then chiselling is done. In this soil is hit hard by sharp end chisel. Dewatering- dewatering of dredge hole is done to reduce buyout force on well thus promoting sinking. Flushing with jet of water on the outside face of well reducing skin friction

Tilt and shift


Tilt and shift are deviation of well from its proposed position

and orientation. Max. tilt allowed is 1/80 Max. shift allowed is 150mm Measures to avoid tilt and shift The outer surface of steining and curb should be kept as smooth as possible. The radius of well curb should be kept more than the steining. The dredging should be done on all sides of well uniformly. Causes Eccentric dredging Can be caused due to boulder under one side

Method of checking tilt and shift


Tilt and shift are calculated with the help of

a level and total station. Method Difference between height of points (1& 3)= R.L.(1)-R.L.(3) Tilt = [ R.L.(1)-R.L.(3)]/diameter Shift at bottom from top position = tilt/ length Note : this process is repeated on sides (2 & 4) and in similar manner tilt is obtained and then combined tilt and shift is reported. Shift of well at top is measured by total station.

Correcting tilt and shift


Regulation of Grabbing

Eccentric Loading
Strutting The well Water jetting or Digging Pit outside the higher side

of well Pulling the well or caisson Excavation on the higher side outside the well

Problems
Sand blowing- This problem occurs when well bottom rests on

sandy strata and dewatering is done below water table. In this sand from ground gushes into the well and there is sudden sinking of well. This sudden sinking is very dangerous and is very difficult to rectify. Bridge scour -is the removal of sediment from bed such as sand and rocks from around bridge, abutments or piers. Scour, caused by swiftly moving water, can scoop out scour holes, compromising the integrity of a structure. Sand heaving-When a well passes through soft strata over a considerable depth, the upward resistance acting on the outside surface of the well is less than the weight of the well. In that situation the well sinks down and quite often a heap is formed inside the dredge hole.

Problems
Bridge scour Sand heaving

Thank You

You might also like