IMPORTANT ELEMENTS OF THE CLEAN AIR EQUIPMENTS

i) Housing- Material of construction should be


compatible to the standards. ii) Filters - Pre filters - Intermediate filters - Fine / Final / Terminal filter iii) Motor Blower assemblyiv) Indicating instrumentv) Lighting arrangementvi) Electrical controls-

IMPORTANT DESIGN PARAMETERS OF THE CLEAN AIR EQUIPMENTS.

i) ii) iii) iv) v) vi) vii) viii) ix)

Material of constructionLaminarity of Air Flow Filtration level & its integritySafety levelSound levelVibrationsLighting level on work surfaceEasy for operations & maintenanceCompetitive Price-

AIR SHOWER

PRINCIPLE OF OPERATION :It gives shower of sterile air with high velocity air jets, which helps to remove suspended particles, bacterias on the clothing of personnel or the material being taken inside the clean room

Application areas for Air Shower


Air shower is installed at entry of i) Clean rooms ii) Operation theaters iii) Calibration laboratory iv) Electronic industries v) Food processing vi) Paint Shop vii) Germs & jewelry for recovering of gold

AIR CURTAINS

PRINCIPLE OF OPERATION :It sucks the surrounding air & blows through special designed rectangular nozzle at a very high speed ( 2400FPM to 3600FPM) which forms invisible curtain between the controlled and uncontrolled environment.

Application areas of Air Curtains


It is fitted or suspended at top of the doors i) Pharmaceutical ii) Operation theaters iii) Food Processing, iv) Dairy v) Sweet mart & Honey collection centers vi) Cold storages as a thermal barrier vii) Show rooms & Offices

LAMINAR FLOW WORK STATION HORIZONTAL

PRINCIPLE OF OPERATION :It sucks the room air through pre-filter and delivers into work area through HEPA filter at laminar air flow. Laminar air flow is horizontal.

LAMINAR FLOW WORK STATION VERTICAL

PRINCIPLE OF OPERATION :It sucks the room air through pre-filter and delivers into work area through HEPA filter at laminar air flow. Laminar air flow is vertical.

Application areas of LAF :i) Laboratories- R& D Biotechnology, Pathology labs ii) Institutes- Agriculture, Pharma, Biotechnology iii)Hospitals- Pathology lab, Blood bank iv) Industries- Electronics, Food processing, Calibration, Watch mfg & repairing, Pharmaceutical, Bearing assly v) Agriculture- Tissue culture

FILTERATION MODULES

PRINCIPLE OF OPERATION :It re-circulates the room air through pre-filter & fine filter so as to achieve the defined no of air changes per hour. It helps to maintain the air borne contamination level of room as per the clean room cleanliness class. All the airborne contaminants gets trapped in the HEPA filter so it needs to be replaced after period of time.

Application areas of FM :i) Laboratories- R& D Biotechnology, Pathology labs ii) Institutes- Pharma, Biotechnology, Agricultural iii)Hospitals- Operation theaters & ICU iv) Industries- Electronics, Food processing, Calibration, Watch mfg & repairing, Pharmaceutical, Bearing assembly v) Agriculture- Tissue culture

ELECTROSTATIC AIR PRECIPITATION UINT

PRINCIPLE OF OPERATION :It consists of pre-filter and electrostatic air precipitator unit, in which fine dust particles up to 0.1 micron are gets collected on stack plates which are connected high DC voltage.

PRINCIPLE OF OPERATION :Main advantage of this ESP unit is that it doesn't require separate blower unit if installed in series with the existing AHU system. Stack assembly can be cleaned & reused again.

Hence power consumption & operational cost is very low compare to HEPA filtration units.
Only drawback of this ESP unit is low filtration efficiency as compare to HEPA filtration units.

Application areas of ESP :i) It is always recommended to use in series with existing Air Handling Unit to reduce the burden on terminal HEPA filters & extend the life . ii) Self air circulating ESP units are suitable to maintain air borne contaminant level in the Telephone exchange, Server Rooms & Broadcasting, which enhances the life of electronics being used. iii)Precision machine shops, calibration labs, quality control depts & banks.

FUME HOODS

Fume hood is confined work chamber and designed to collect all fumes generated on worktop during the process and exhaust directly to the environment through filtration system. Application areas -Research laboratories -Pharma - Chemical industries

STERI AIR

STERI AIR is a small & compact filtration unit with pre-filter, HEPA filter , Activated Carbon Filter and Negative ionizer.

Longevity is suitable for,

-Small Offices, -Bars & Restaurant to minimize the cigarette smoke, -Server Rooms, -Patients having asthma, allergy, headache & fatigue .

GARMENT CABINETS

Garment cabinet consists of pre-filter, HEPA filter Blower assembly & UV light. This provides sterile environment for the sterile Garment, curb growth of bacteria .

CLEAN AIR EQUIPMENTS FOR HAZARDOUS AREA APPLICATIONS


These Clean Air Equipments are designed for hazardous area Zone 1, Gr IIA/ IIB application like, -Pertochemical industries,

-Pharma industries where highly inflammable chemicals are used - Satellite launching station,
- Chemical industries ,ammunition industries