You are on page 1of 19

Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux

0


Overview Of Lighting Fixtures

31-Jan-2013

Presenter Annasaheb Shende


Lighting Fixtures Business
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
1
Headline

One of the factor involved in improving
work efficiency

Quality of light & light Efficiency


NEW ERA OF IMPROVED EFFICIENCY
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
2
QUALITY OF LIGHT
Light with CRI very close to daylight
Light with better Color Temperature
Strobe free light
Glare free light
Uniform spreading of light

This improves the vision quality &
reduces the eye strain
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
3

Best lumen per watt
Better lumen maintenance - @ 90 %
Reduced Total Harmonic Distortion
Unity power factor Reduced load on distribution
system
Longer life of lamp & control gear
Reduced replacement cost

LIGHT EFFICIENCY
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
4

We INTELUX help our product users by
providing the most efficient lighting systems
which meet all the parameters mentioned in
Quality & Efficiency of light.
OUR COMMITMENT
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
5
Types of conventional & energy efficient options
Area Type of
conventional fitting
used
Wattage (Including
choke losses)
Energy efficient
option
Wattage (Incl.
ballast losses)
Cane Yard 250 W / 400 W HPSV 280W / 450 W 4 x 24 W T-5 / 4 x 36
W PLL streetlight
96W / 144W
Cane Handling 250 W / 400 W HPSV 280W / 450 W 4 x 24 W T-5 / 4 x 36
W PLL streetlight
96W / 144W
Mill House 400 W HPMV / MH 450 W 4 x 54 W T-5 Highbay 216 W
Side area 2 x 40W FTL 100 W 2 x 24 W T-5
streetlight fitting
48 W
Basement 1 x 40 W FTL open
type fitting
50 W 2 x 18 W IP -65 36 W
Control Room 1 x 40 W FTL 50 W 1 x 36W FTL 36 W
Boiling House + Sugar
House
400 W HPMV / MH 450 W 4 x 54 W T-5 Highbay 216 W
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
6
Types of conventional & energy efficient options
Area Type of
conventional fitting
Wattage (Including
choke losses)
Energy efficient
option
Wattage (Incl.
ballast losses)
Various floors of
boiling house & sugar
house
2 x 40W FTL open
type fitting
100 W 2 x 36W FTL IP-65 72 W
Boiler Section 70 W HPSV / MH
wellglass fitting
90 W 2 x 24 W T-5 (IP 65 )
fittings
48 W
Power House 2 x 40W FTL
conventional fittings
100 W 2 x 36W FTL Energy
Efficient fitting
72 W
Distillery 125 W HPMV / 160 W
MLL wellglass / 2 x 40
W FTL flameproof
fitting
145 W / 160 W /100
W
2 x 26 W PLL
Flameproof / 40 W
LED flameproof
wellglass fittings
52 W / 40 W
ETP 150 W HPSV /250 W
HPMV streetlight
175 W / 280 W 4 x 24W T-5 streetlight
fitting
96 W
Outdoor streetlights 150 W HPSV / MH
streetlight fittings
175 W 4 x 24W T-5 streetlight
fitting
96 W
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
7
400 W HPMV/MH High bay

Wattage 450 Watts
Lamp life 6,000 / 15000 Br. Hrs
THD < 30 %
Light with full of strobe
Tremendous heat generation
Color difference / shift problem
Lumen maintenance 40 - 50%
CRI 45 / 70 , CCT 5000
0
K


Choke + Capacitor + Igniter + Lamp
More components & less life -
Increased maintenance cost
Reigniting problem it takes
@ 8 -10 minutes, so inverter + extra
emergency lamps required

EELS 454 High bay (T-5)

Wattage 216 Watts
Lamp life 20,000 Br. Hrs
THD < 10 %
Strobe free light
Reduced heat
No color difference / shift
Lumen maintenance 90 %
CRI > 85, CCT 6500
0
K


Ballast + Lamp - Reduced components &
better life
- reduced maintenance cost
Instant start
no need of inverter
COMPARISON
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
8
400 W HMV/MH High bay EELS 454 High bay (T-5)

DETAIL COST ANALYSIS

Wattage 450 W
(Incl. Choke losses)
Current - @ 2.3Amp
Consumption per 365 days
12 hrs
450W x 12 hrs x 365 days
= 1971Units
Electricity charges
(units x Rs. 4.50/-)
= Rs. 8,870 / -

Wattage 216 W
(Incl. ballast losses)
Current - @ 1 Amp
Consumption per 365 days
12 hrs
216W x 12 hrs x 365 days
= 946 Units
Electricity charges
(units x Rs. 4.50/-)
= Rs. 4,257 / -

Saving of Rs. 4,613/- per fixture per annum
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
9
70 W HPSV Well glass
Wattage 450 Watts
Lamp life 6,000 / 15000 Br. Hrs
THD < 30 %
Light with full of strobe
Tremendous heat generation
Color difference / shift problem
Lumen maintenance 40 - 50%
CRI 45 / 70 , CCT 5000
0
K


Choke + Capacitor + Igniter + Lamp
More components & less life -
Increased maintenance cost
Reigniting problem it takes
@ 8 -10 minutes, so inverter + extra
emergency lamps required

EELS 224 IP - 65

Wattage 216 Watts
Lamp life 20,000 Br. Hrs
THD < 10 %
Strobe free light
Reduced heat
No color difference / shift
Lumen maintenance 90 %
CRI > 85, CCT 6500
0
K


Ballast + Lamp - Reduced components &
better life
- reduced maintenance cost
Instant start
no need of inverter
COMPARISON
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
10
70 W HPSV Well glass

EELS 224 IP - 65

DETAIL COST ANALYSIS

Wattage 90 W
(Incl. Choke losses)
Current - @ 0.8 Amp
Consumption per 365 days
12 hrs
90W x 12 hrs x 365 days
= 394Units
Electricity charges
(units x Rs. 4.50/-)
= Rs. 1,773 / -

Wattage 48 W
(Incl. ballast losses)
Current - @ 0.21 Amp
Consumption per 365 days
12 hrs
48W x 12 hrs x 365 days
= 210 Units
Electricity charges
(units x Rs. 4.50/-)
= Rs. 945 /
Saving of Rs. 828/- per fixture per annum
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
11

250 W HPSV/ HPMV Streetlight
EELS 424 Streetlight (T-5)

COMPARISON
Wattage 280 Watts
Lamp life 15000 Br. Hrs
THD < 30 %
Light with full of strobe
Tremendous heat generation
Colour difference / shift problem
Lumen maintenance 40 - 50%
CRI 25 / 45 , CCT 2,700 /5000
0
K


Choke + Capacitor + Igniter + Lamp
More components & less life -
Increased maintenance cost
Reignition problem it takes
@ 8 -10 minutes, so inverter + extra
emergency lamps required

Wattage 96 Watts
Lamp life 15,000 Br. Hrs
THD < 10 %
Strobefree light
Reduced heat
No colour difference / shift
Lumen maintenance 90 %
CRI > 85, CCT 6500
0
K


Ballast + Lamp - Reduced components &
better life
- reduced maintenance cost
Instant start no need of inverter + extra
emergency lamps


Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
12
250 W HPSV/ HPMV Streetlight

EELS 424 Streetlight (T-5)

DETAIL COST ANALYSIS

Saving of Rs. 3627/- per fixture per annum
Wattage 96 W
(Incl. ballast losses)
Current - @ 0.42 Amp
Consumption per 365 days
12 hrs
96W x 12 hrs x 365 days
= 420 Units
Electricity charges
(units x Rs. 4.50/-)
= Rs. 1,890 / -

Wattage 280 W
(Incl. Choke losses)
Current - @ 1.5 Amp
Consumption per 365 days
12 hrs
280W x 12 hrs x 365 days
= 1226 Units
Electricity charges
(units x Rs. 4.50/-)
= Rs. 5,517 / -
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
13
ENERGY EFFICIENT SEMI HIGH MAST
There is an option of energy efficient semi high mast using 12 No's of
4 x 24 W T-5 Energy efficient streetlight fittings (@ 12 No's) on a
single pole.


Results are-

Substantial energy saving of @ 50 %.
Very good area coverage (i.e. area of @ 60 mtrs Diameter)
Very good visibility .
Reduction in pole investment for streetlights.
Saving in cable length.
thus drastically reduction in initial investment.
Easier for maintenance.
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
14
Length of Semi High Mast Pole 11 mtrs
Energy Efficient lighting system 12 Nos. EELS 424 SL (Total Wattage = 1.15 KW,
Very good light quality, Best vision, CRI >80, Colour Temp - 6500
0
K ) ,
No maintenance problem, I nstant start.
ENERGY EFFICIENT SEMI HIGH MAST
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
15
BOILER MILL HOUSE & TURBINE
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
16

Vision under previous HPSV Streetlight Vision under T -5 Energy Efficient streetlight
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
17
Vision under HPMV fittings Vision under T-5 fittings

Comparison of vision under HPMV & T-5 Fittings
Intelux 2012, no part of this document may be circulated, quoted or reproduced without prior written approval of Intelux
18


Thank You

You might also like