You are on page 1of 51

VERSION 2.

0
Building Telephone
Facilities
HUAWEI GROUP
PHOTOCOPY
& PRINT
Up
U
p
OFFICE
LUNCH
ROOM
OFFICE
OFFICE OFFICE
OFFICE
STAIRS
STAIRS
RECEPTION
OFFICE
I.T. ROOM
EQUIPMENT
ROOM
ENTRANCE
RESTROOM
RESTROOM
1
st
Floor Plan
Up
U
p
OFFICE
OFFICE OFFICE
OFFICE
STAIRS
RECEPTION
STAIRS
CONFERENCE
ROOM
VICE
PRESIDENTS
ROOM
PRESIDENTS
ROOM
OFFICE
RESTROOM RESTROOM
LUNCH
ROOM
RECORDS
PHOTOCOPY
& PRINT
2
nd
Floor
Plan
Up
U
p
BEDROOM BEDROOM
BEDROOM
BEDROOM
BEDROOM
DINING
ROOM
DINING
ROOM
DINING
ROOM
DINING
ROOM
DINING
ROOM
RESTROOM
RESTROOM RESTROOM
RESTROOM
RESTROOM
LIVING ROOM
LIVING ROOM
LIVING ROOM
LIVING ROOM
LIVING ROOM
STAIRS
STAIRS
3
rd
to 6
th

Floor Plan
MTTC
Riser
6th floor 10 lines
5th floor 10 lines
4th floor 10 lines
3rd floor 10 lines
2nd floor 30 lines
1st floor 30 lines
RISER SYSTEM
Open Riser Shaft Slot
Type

DISTRIBUTION
SYSTEM
First and Second Floor
Raised Floor (Unlimited
Access)
Third to Sixth Floor
Underfloor Conduit
SERVICE ENTRANCE
Underground Service
Entrance

MAIN TERMINAL
Main Telephone
Terminal Cabinet
Second
Floor
Riser
Conduits
Ground
Floor
S
I
D
E
W
A
L
K
S
I
D
E
W
A
L
K
SERVICE
BOX
ENTRANCE
CONDUIT
M
T
T
C
COMPANY
MANHOLE
LATERAL CONDUITS
GRADEDTOWARDS
COMPANY MANHOLE
PROPERTY LINE
BUILDING
LINE
STREET
THIS IS TO BEPROVIDEDBY THECOMPANY THIS IS TO BEPROVIDEDBY THEBUILDING OWNER
PROPERTY LINE
M
T
T
C
TTC
0.9 m(H) x 1.2 m(V) x 1.2 m(D)
Concrete service box
Inside property line/ Non-vehicular
R = 10 x D
At least 2-114.5 mm
conduits or as
required
This is to be
provided by owner
up to their property
line
YELLOW LATERAL CONDUITS - AT LEAST
2-114.3 mm diameter CONDUITS
(This is to be provided by the company)
R= not
less
than
3.00 m
1.00m
2-50 mmdiameter
Up
U
p
Underground Service Entrance
TTC 2
Service Box
0.91 x 1.23 x 1.21 m
H V D
Second Floor
TTC 4
TTC 5
TTC 3
TTC 1
10
Fourth Floor
Sixth Floor
Third Floor
Fifth Floor
PROTECTED
HC 1-10
T-5
T-1
T-3
T-2
T-6
10
10
10
25
90
T-4
HC 11-20
HC 21-30
HC 66-90
HC 41-65
HC 31-40
9
0
x
0
.
5
HC 1-90
HC 1-30
Ground Floor
T.
1.0 m
90x0.5
1-12mm of PVC
Ground Pipe
1.22 x 1.37 x 0.15 m
H D V
2

x

5

m
m

o
f

R
S
C
C
O
N
D
U
I
T
0
.
9
1

x

0
.
9
1

x

0
.
1
5

m



H








V









D
2-50 mm of RSC ENTRANCE CONDUIT
ENTRANCECABLEFACILITIES TO BE
PROVIDEDBY THETELEPHONECOMPANY
COPPER
GROUND WIRE
C
O
N
D
U
I
T

R
I
S
E
R

D
I
A
G
R
A
MC
A
B
L
E

R
I
S
E
R

D
I
A
G
R
A
M
Up
U
p
Distribution System for 1st Floor
Raised Floor
Riser
Up 1
st
Floor Plan
Up
U
p
Distribution System for 2nd Floor
Raised Floor
Riser
Down
Riser
Up
2
nd
Floor
Plan
Up
U
p
Distribution System for 3rd to 6th Floor
Conduit
Riser
Down
Riser
Up
3
rd
to 6
th

Floor Plan
Service Box 1
MTTC 1
TTC 6
Junction Boxes 20
Handset 53
The wiring network that carries all the data, voice,
multimedia, security, VoIP, PoE, and even wireless
connections throughout your building or campus.
As important to the success of your organization as the
people are who work in it.
Facilitates the continuous flow of information, enables
the sharing of resources, promotes smooth operations,
accommodates ever-changing technology, offers plenty
of room for growth, and evolves with your organization.
Entrance Facility
Equipment Room
Telecommunication Room
Horizontal Cabling
Backbone Cabling
Work Area

Cost
Installation of Equipment
Standards (Cables, Equipment,
etc.)
Application
Life Cycle
Compatibility
Bandwidth
Growth
MACs (Moves, Adds and Changes)
Encompasses everything between the telecommunications
room cross connects to the outlets in the work area.
Specifies:
Horizontal cabling.
Telecommunications outlets.
Telecommunications connectors.
Cross-connects.
Patch cords.
Consolidation point (if any).

Provides the main information conduit connecting all your
horizontal cabling within a building and between buildings.
Specifies:
Cabling
Intermediate and main cross-connects
Mechanical terminations
Patch cords or jumpers for backbone-to- backbone
connections

Consists of all the components between the
telecommunications outlet and the users desktop
workstation equipment.
Covers:
Telecommunications outlets, including wallplates,
faceplates, surface-mount boxes, etc.
Patch cables.
Adapters, including connectors, and modular jacks.
Workstation equipment, such as PCs, telephones,
printers, etc. although they arent included in the standard.

Houses all the equipment associated with connecting the
backbone wiring to the horizontal wiring.
Includes:
Intermediate cross-connects
Main cross-connects
Patch cords
All connecting equipment
The telecommunications room can also house auxiliary
equipment such as a PBX, security equipment, etc.

Houses telecommunications systems, such as PBXs, servers,
routers, switches, and other core electronic components as
well as the mechanical terminations.

Point where the outdoor plant cable connects with
the buildings backbone cabling.
Includes:
Cables.
Connecting hardware.
Protection devices.
Fibre Optic Hand Tools
Single mode & Multimode
Internal/External Fibre Optic
Cables
Splice Enclosures
Wall/Rack mounted Patch
Panels












Up
U
p
RESTROOM
RESTROOM
OFFICE
PHOTOCOPY
LUNCH
ROOM
OFFICE
OFFICE OFFICE
OFFICE
STAIRS
STAIRS
RECEPTION
OFFICE
I.T. ROOM
EQUIPMENT
ROOM
VESTIBULE
Second
Floor
Riser
Conduits
Ground
Floor
S
I
D
E
W
A
L
K
S
I
D
E
W
A
L
K
SERVICE
BOX
ENTRANCE
CONDUIT
M
T
T
C
COMPANY
MANHOLE
LATERAL CONDUITS
GRADEDTOWARDS
COMPANY MANHOLE
PROPERTY LINE
BUILDING
LINE
STREET
THIS IS TO BEPROVIDEDBY THECOMPANY THIS IS TO BEPROVIDEDBY THEBUILDING OWNER
PROPERTY LINE
M
T
T
C
TTC
0.9 m(H) x 1.2 m(V) x 1.2 m(D)
Concrete service box
Inside property line/ Non-vehicular
R = 10 x D
At least 2-114.5 mm
conduits or as
required
This is to be
provided by owner
up to their property
line
YELLOW LATERAL CONDUITS - AT LEAST
2-114.3 mm diameter CONDUITS
(This is to be provided by the company)
R= not
less
than
3.00 m
1.00m
2-50 mmdiameter
TTC 2
Second Floor
TTC 4
TTC 5
TTC 3
TTC 1
10
Fourth Floor
Sixth Floor
Third Floor
Fifth Floor
PROTECTED
HC 1-10
T-5
T-1
T-3
T-2
T-6
10
10
10
30
100
T-4
HC 11-20
HC 21-30
HC 70-100
HC 41-70
HC 31-40
1
0
0
x
0
.
5
HC 1-90
HC 1-30
Ground Floor
T.
100x0.5
2

x

5

m
m

o
f

R
S
C
C
O
N
D
U
I
T
0
.
9
1

x

0
.
9
1

x

0
.
1
5

m



H








V









D
ENTRANCECABLEFACILITIES TOBE
PROVIDEDBY THETELEPHONECOMPANY
COPPER
GROUND WIRE
C
O
N
D
U
I
T

R
I
S
E
R

D
I
A
G
R
A
MC
A
B
L
E

R
I
S
E
R

D
I
A
G
R
A
M
IP-PBX
Service Box
0.91 x 1.23 x 1.21 m
H V D
1.0 m
1-12mm of PVC
Ground Pipe
2-50 mm of RSC ENTRANCE CONDUIT
1.22 x 1.37 x 0.15 m
H D V
TTC
Up
U
p
Horizontal Cabling for 1st Floor
Riser
Up
IP-PBX
Up
U
p
Horizontal Cabling for 2nd Floor
Riser
Down
Riser
Up
Up
U
p
Horizontal Cabling for 3rd to 6th Floor
Riser
Down
Riser
Up
Service Box 1
MTTC 1
TTC 6
Junction Boxes 20
Handset 53
Wallplates 53
Description of the System
Internet Protocol Private Branch Exchange
(IP PBX)
Users adopt to various types of terminals
Design Considerations
Design Parameters
Item Application
Ports 284 ports
Built in Voice Mail 10 channels concurrently
System Reliability 99.995%
Manageability Centralized/Remote equipment management,
signaling tracing, resource tracing, alarm
management, and quick deployment
The following table lists some of the technical specifications of the eSpace
U1930.
Up
U
p
M
T
T
C
Equipment
Room
Up
U
p
M
T
T
C
Equipment
Room
IP
PBX
Riser System
Features of IP PBX
High integration and hybrid design.

It supports different types of terminals

The u1930 designs to support both ac
and dc power supplies with backup,
unified management, and intuitive quick
deployment.
Cost OF IP PBX
Php 206,329.20
IP PBX
1
st
Floor 1
TOTAL 1
List of Materials

You might also like