You are on page 1of 51

Nemo Outdoor User Training

Nemo User Training


Course Contents
Nemo Outdoor_Indoor Basic Installation
Hardware Configuration
Nemo Outdoor Measurement Configuration
Introduction to Graphical User Interface
Nemo Outdoor Playback & File Formats

Nemo Outdoor_Indoor Installation


-

Nemo Outdoor_Indoor License Option


Basic SW Installation

Copy Protection
Nemo Outdoor uses either software or hardware
protection. (Indoor and Outdoor measurement are
restricted by dongle options)
Various available options are configured with each
copy protection module.

Nemo Outdoor/Indoor Installation


Installation:

You need to have local Administrator rights to install Nemo Outdoor


Run the Nemo Outdoor setup.exe file and follow the instructions. Current
Nemo Outdoor SW is 4.20.73 Check the latest versions of Nemo software from
our web pages at (www.nemotechnologies.com) Valid to users with Technical
Support Agreement only.

Install DKU 2 cable driver.


Restart laptop

HARDWARE SETUP

Testing Concept Voice Call


The voice testing
environment consists of
Nemo Outdoor
compatible test
measurement mobiles
Laptop/Tablet PC with
Nemo Outdoor
installed
Necessary connecting
cables
GPS receiver for
Outdoor measurement
(optional) fast
frequency scanner.

Testing Concept PS Data Call


The PS data testing
environment consists
of Nemo Outdoor
Application
Server(e.g. FTP
server, HTTP server,
POP3 server, SMTP
server, or WAP
server)

Nemo Outdoor Measurement Configuration

Manual / Automated Mode


Nemo Outdoor supports manual and automated mode.

Manual mode is based on the user establishing a data transfer connection or


making voice calls.
-

This mode is useful, when user wants to make a single continuous data
transfer session or a voice call to monitor the resource allocation and cell
reselection performance.

This mode requires the user to control phones with Nemo Outdoor. The
user should NOT use the mobile keyboard to establish voice calls or data
calls.

Automated mode is based on scripts that establish data transfer connections or


voice calls on behalf of the user and can repeat the same or different sessions for a
defined period of time. Scripts can be saved and edited. Script files can be, quickly
and easily built with the Script Editor.

Introduction to Graphical User Interface


Device Info
Configuration:
Device Info:
( )view disp parameters
( )define displayed parameters
( )configure notifications
( )control phone
( )configure measurement
parameters

Measurement Properties

Measurement properties for


Voice Calls, Data calls etc.
Need to be defined before the
actual measurement

Manual Measurement Configuration


Information on this tab should be filled in when doing
Manual Measurement. (Press Properties)

Voice Number defines the phone number to which


voice calls will be made.
Data Number defines the phone number for data
calls, user name and password for service, etc.
PDP Context Properties defines used APN for Packet
data connection
Data Protocol defines whether FTP or UDP is used
for data transfer
ICMP Ping Properties defines Ping settings, like Ping
address and size of Ping data

Manual Measurement Control


Measurement can be done from Mobiles
Control Panel or from Measurement menu
by selecting the appropriate mobile

Automatic Measurement
Measurements can be automatically repeated by predefined number of times
Voice calls, data calls, attach, PDP activation, FTP, Web browsing, SMS, MMS, launch of
external application, Ping sessions, etc. can be included in automatic measurement
sequence
Add / Modify / Delete / Move up / Move down / Append script / Repeat script value/ New
/Open / Save / Save As...

Voice Call Script Configuration


Script Editor/ Add / Voice Call
Voice Call Properties
Number defines the
number to be called
Call Duration determines
the time that the call lasts
in seconds
Call Attempt Timeout value
determines the maximum
duration of the call
attempt. After that, the
call attempt is considered
to be failed.

PS Script Configuration

Application Testing

Access Point Name


defines the APN used
User Name/Password etc.
Depend on operators
settings

PS Script Configuration
Host Name: IP address of the FTP server
used.
Username: username for the FTP server.
Password: password for the FTP server.
Passive Mode: Some firewalls may be
configured to refuse any incoming
connection requests, and in that case the
data transfer would fail. With passive
mode, the client always opens those new
connections so the firewall does not block
the connection.
Direction: Receive downloading; Send
uploading
Remote File: File @ FTP Server
Local File: File @ Testing laptop

PS Script Configuration
URL: IP address of the test file that will
be downloaded. For example,
203.125.58.120/1000kb.htm

Local File: File

@ Testing laptop

Script Configuration
Editing PS Script

Ping Test
The ICMP (Internet
Control Message
Protocol) Ping
functionality allows you to
perform ping
measurements
simultaneously with FTP
testing and data transfers

Script Enhancements
Possibility to synchronize scripts
repeats between devices for
benchmarking measurements.
Improved wait function allows
waiting for notifications during
script measurements.
Option to use measurement
settings configured for manual
testing during script
measurements.

Event Trigger Notifications


By clicking the Notifications sheet, you
can access the Notifications dialog box

Select the Events that you would like to


be notified of and also select whether the
notification will be a textual note in the
Output window, a sound (.wav file), or a
bitmap
Own notifications can be created for
different situations, like bad quality
example below, in Configuration tool

User Defined Event Trigger Configuration I


Static triggers
Static triggers are made available in
Nemo Outdoor by default and can
collect statistics.
User configurable event trigger

User Defined Event Trigger Configuration II

Bitmap image Audio Wave Notification

Event Trigger Configuration

Event bitmap
displayed in map
window

Event bitmap
displayed in line
graph

(1.) Textual Notification


displayed in the Output window

(2.) Sound Notification

Real-time monitoring during measurement

Real-time monitoring during measurement

Introduction to Nemo Outdoor


Graphical User Interface

Introduction to Graphical User Interface

Introduction to Graphical User Interface


Script Status
window

Output window
Status bar

Introduction to Graphical User Interface


Windows: Graphs
Line Graphs allow the user to accurately observe the measurement information.
zoom
thresholds
scale
selectable parameters & values
selectable layers & values
average value presentation
displaying events & notifications

Workspace and Hardware Configuration


By saving the workspace, different views can be saved to a .wor file. The following
views are saved to the file:
Device Information Window views
Grid and Graph views

Color Set and Parameter selected in the Map Window (Map layers must be
saved to MapInfo .gst file)
By saving the hardware configuration file, the information related to device(s) is
saved to the .hwc file:

All information defined in the Measurement Properties Window

Introduction to Graphical User Interface


Windows: Graphs
Line graph

Bar graph

Introduction to Graphical User Interface


Windows: Graphs

Scanning results

Scatter plot

Introduction to Graphical User Interface

Windows: Grids

The user can easily select the events, parameters, and statistics to be
displayed in the grid table. It is also possible to highlight certain events
with color to improve the clarity of the results presented. Double-click on
an event to view more information about that particular event.

Introduction to Graphical User Interface


Windows: Grids
Parameters
Events

Introduction to Graphical User Interface


Windows: Grids

Layer3

Statistics

Decoded Layer3

Introduction to Graphical User Interface

Textual Windows: Grids


Statistics

Graphical Windows: Graphs


Scatter plot

Decoded Layer3
Events

Scanning Plots

Parameters
Layer3

Table

Line graph

Bar graph

Nemo Indoor & Floor plan


Nemo Indoor
supports indoor
floor plan in .tab;
.bmp; .jpg; .tif
formats.

Nemo Indoor & Floor plan


During
measurement,
markers( ) need
to be inserted in
order to plot
route on floor
plan.

Nemo Indoor & Floor plan


Indoor floor plan
properties

Nemo Outdoor and MS BTS File

Multiple Real-time Route Coloring

New multi route feature allows users to compare easily


measurements from different terminals on the same map or to
correlate different parameters from the same terminal.

A line from the test vehicle to


the serving and neighboring
BTS can be drawn.

Playback in Nemo Outdoor

The Play button starts the playback


The Pause button pauses the playback

The Stop button stops the playback


Add Marker
Add Textual Note
Playback Speed

Files Used by Nemo Outdoor

Files Used by Nemo Outdoor


BTS files
.bts, .nbf
MAP files
MapInfo vector and raster maps
Result files
.dt1, .dt2, .dt3, .dt4
.fs1, fs1, fsn
.ft1, ft2, ftn

Workspace files
.wor
Hardware configuration files
.hwc
Script files
.nsf

Nemo Outdoor Measurement File


With Call mode measurements, *.DT1 file is produced.
With Frequency/Pilot Scan (Separate Scanner) measurements , *.FS
file is produced.

Open ASCII non-proprietary file format


Easy to view and use

Nemo Outdoor Measurement File Contents


Field strength results of the serving and neighbouring cells
Quality class values
Mobile output power level
Layer 3, layer 2, RLC/MAC, LLC and RRC messages
Geographical coordinates and time
Call events and handover events
Location update events
Channel information
Other information

Example of Nemo Outdoor Measurement File header


*** Nemo Outdoor 4.12.22

ff ver 1.72

28.01.2004

11:47:41

#ID Id tag for simultaneous measurement files

: {342E0B9C-E2B5-495e-97AC-87D2B710A166}

#AG External antenna gain (dBi)

: 0.00

#BF BTS filename

#CF Call list filename

: d:\Nemo Tools\deactivate.nsf

#CL External cable loss

: 0.00

#CM Call mode

: Originate

#HV Handler version

: 4.01.12

#MF Map filename

#MT Mobile type

: T260

#NN Network name

#NT Network type

: GSM 900/GSM 1800

#PN Test call phone number

#SW Device software version

: af.7f.cb

#HW Device hardware version

: 4C7

GAA 0.000000 0.000000 0 0 0 0 0 11:47:42.827


GAC 0.000000 0.000000 0 0 0 0 0 11:47:42.827 8
LUA 0.000000 0.000000 0 0 0 0 0 11:47:42.827

Questions?

THANK YOU!

You might also like