You are on page 1of 37

RG10(BSS) for Network Planners

Customer training material

Nokia Siemens Networks

RN20092EN14GLN0

RG10 for Network Planners


Site Solution Hardware Support
Flexi BSC(3i 3000) and Double Capacity AS7 Unit_BSS21149
Integrated IP card for BSC3i and TCSM3i_BSS21157
PCU2 HW Evolution and Asymmetrical PCU HW configuration_BSS21226
Radio Network Performance
AMR Handover Signaling Optimization_BSS20916
Unpacking AMR_BSS21120
Wideband AMR_BSS20960
Tandem Free Operation (TFO) for AMR_BSS21118
SDCCH and PS Data Channels on DFCA TRX_BSS21161
Downlink Dual Carrier_BSS21228
Improvement in Operability
Energy Saving Mode For BCCH TRX_BSS20958
Flexi EDGE Dual TRX Automatic Power Down_BSS20984

Nokia Siemens Networks

RN20092EN14GLN0

Site Solution
Hardware Support

Flexi BSC and Double Capacity AS7 Unit

Benefits
Architecture
Configuration steps
PCU capacity
Dimensioning rules (BSC, BCSU, PCU, ET)

Nokia Siemens Networks

RN20092EN14GLN0

Site Solution
Hardware Support

Flexi BSC benefits


Flexi BSC reduces OPEX

Circuit-switched capacity for voice 18000

Flexi BSC

PDFU

PDFU

Erlangs

GTIC

ETC

ETC

GSW2KB

GTIC

ETC

ETC

CLS

Packet data capacity for EDGE evolution up to

GSW2KB

30720 Abis links (16kbit/s)


cabinet

New support of IP/Ethernet for all interfaces


Flexible transmission types (E1/T1, STM-1/OC3, IP/Ethernet)

Excellent power consumption efficiency


Nokia Siemens Networks

FTRB
BCSU 4

Very high footprint efficiency

BCSU 1

RN20092EN14GLN0

MCMU

500 TRX to 3000 TRX, license step one TRX

LANU

BCSU 7

OMU

BCSU 2

BCSU 3

FTRB
LANU

Scalable in 6 HW capacity steps (BCSUs) from

FTRB
MCMU

FTRB

CLS

3000 TRXs and 3000 BTS sectors/sites in one

BCSU 5

BCSU 6

Site Solution
Hardware Support

Flexi BSC architecture


Marker and Cellular Management Unit
(MCMU)
Base Station
Controlling and
Signalling Unit
(BCSU)

Supervising of GSWB, executing RRM


functions, internal traffic handling by
Ethernet Message Bus (EMB) and LAN
Switching Units (SWUs)

Handling of
signalling traffic
(LAPD, SS7) incl.
PCU

Exchange Terminal (ET)


Connecting of transmission
systems (E1/T1, STM1/OC3,
PWE3) to GSWB; several ET
types are possible within Flexi
BSC: ET16, ETS2, ETIP

Nokia Siemens Networks

Bit-oriented Group
Switch (GSWB)
Switching CS/PS traffic,
connecting signalling
circuits

RN20092EN14GLN0

Operation and Maintenance Unit


(OMU)
Supporting O&M for Flexi BSC
incl. storage devices (interfaces to
user/OMC/transmission/peripherals
, alarm collection and indications,
system configuration/management,
BSC3i maintenance/administration,
LAN topology management)

Clock and Synchronization


Unit (CLS)
Generating clock signals for BSC3i

Site Solution
Hardware Support

Flexi BSC Configuration Steps


Overview on Flexi BSC capacity
The following table presents the main capacity figures of the Flexi BSC
#TRX per BSC

1500

5011000

10011500

15012000

20012500

25013000

#active BCSU

500

1000

1500

2000

2500

3000

10

15

20

25

30

max #PS Abis chan@16

5120

10240

15360

20480

25600

30720

max #RTSL

4000

8000

12000

16000

20000

24000

max #SS7 links:


64 kbps
128 kbps
256 kbps
512 kbps
1024 kbps
HSL

0
8
4
2
2
1
2

0
16
8
4
4
2
4

0
16
12
6
6
3
6

0
16
16
8
8
4
8

0
16
16
10
10
5
10

0
16
16
12
12
6
12

max #LAPD (*1)

992

1984

2976

3968

4960

5952

50
16
8

50
16
8

50
16
8

50
16
8

50
16
8

50
16
8

max #BTS / #BCF


max #logical PCU2-E

#PCM (*2):
ET16
SET
ETIP

(*1): #LAPD links achievable with low capacity SS7 links. Therefore in 3000 TRX conf. SS7 over IP (SIGTRAN) is recommended.
(*2): #controllable PCM lines does not depend on #BCSU

Nokia Siemens Networks

RN20092EN14GLN0

PCU capacity in Flexi BSC

Site Solution
Hardware Support

PCU functionality in Flexi BSC can be realized by both:


- PCU2-E, a new plug in unit offering significant capacity enhancements
- PCU2-D,

The following PCU configurations are feasible in Flexi BSC :


- Each BCSU can be equipped with up to 5 PCU
- BCSU can have a mixture of PCU2-D/PCU2-E
- With Asymmetric PCU configuration feature all BCSUs within one BSC
do not need identical PCU configurations
- PCU2-D comprises 2 logical PCU, each logical PCU can handle up to
256 Abis PS channels@16
- PCU2-E comprises 1 logical PCU, it can handle up to 1024 Abis PS
channels@16.

Nokia Siemens Networks

RN20092EN14GLN0

Site Solution
Hardware Support

Dimensioning
Flexi BSC
Dimensioning concept same as with BSC3i:

- All static and dynamic limits are checked against the corresponding values determined per
planning area
- The basic formula is used to calculate the number of BSCs in a given area

N TRX , region
min N BSC max
max N TRX , BSC

max N BTS , BSC

N BTS ,region

N BCF ,region

max N BCF , BSC

...
max Erl BSC

;

Erl region

- The initial BSC utilization level is considered to leave capacity for future extensions and traffic
growth

Flexi BSC offers high scalability and configuration variety:


- In a given BSC the following items are calculated
- The number required of BCSUs
- The number of required PCUs
- The number and types of the interface units/ports

Nokia Siemens Networks

RN20092EN14GLN0

Site Solution
Hardware Support

Dimensioning
BCSU

Working BCSU is needed for each 500 TRXs


Every BCSU is equipped with the number of AS7-D units sufficient to handle signalling traffic

produced by 500 TRX


Also other units (power supply, CPU, memory) are always installed and do not need to be computed
Apart from this, BCSU can be equipped with up to 5 PCUs
The number of working BCSU per Flexi BSC can be computed by formula below:
N TRX , BSC
N BCSU , BSC max
500

N PCU , BSC

5

Regardless of the amount of working BCSU an extra spare one is always needed for
redundancy
N+1 redundancy principle applies for the BCSUs

Nokia Siemens Networks

RN20092EN14GLN0

Site Solution
Hardware Support

Dimensioning
PCU2-E

PCU2-E has several static limits (#Abis channels, #TRX, #BTS, #segments, #EDAPs, )
(For details about PCU2-E static limits please refer to product documentation)

Usually the most critical parameter in PCU dimensioning is the number of Abis
channels that can be managed by PCU
PCU2-E serves 1024 Abis channels@16 kbps
PCU2-D serves 256 Abis channels@16 kbps

The number of PCU can be computed by means of the formula below:



N Abis , BSC
N PCU , BSC max
max N Abis , PCU

10

Nokia Siemens Networks

max N TRX , PCU

N TRX , BSC

RN20092EN14GLN0

N cells , BSC

max N cells , PCU

N seg , BSC

N EDAP , BSC

max N seg , PCU

max N EDAP , PCU

;...

Dimensioning
ET

Site Solution
Hardware Support

The number of Exchange Terminals (of given type) depend on how many PCM lines is
terminated in Flexi BSC and what connectivity configuration has been chosen

The number of PCM lines can be computed by means of the formula below:

N PCM , BSC N PCM _ Abis , BSC N PCM _ Ater , BSC N PCM _ Gb , BSC

The next step is to decide which PCM lines will be connected to ET16, ETS2 and ETIP
and to compute the required amount of PIU and cartridges to be installed

11

Nokia Siemens Networks

RN20092EN14GLN0

Site Solution
Hardware Support

Dimensioning
ET

Then the number of particular PIU can be computed as follows (ETSI standard):

N SET , BSC

N PCM , ETS 2

63

N PCM , ET 16

16

N ET 16 , BSC

N ETIP , BSC max PCM , ETIP


126

N PW , BSC
;...
512

Please note that the actual number of ETS2 PIU depends on the number of required SET
and number of optical interfaces activated per ETS2 (1 or 2 optical interfaces may be
active):
NETS 2,BSC NSET,BSC

- 1 optical interface per ETS2 active:


NETS 2,BSC NSET,BSC / 2

- 2 optical interfaces per ETS2 active:

12

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for


BSC3i and TCSM3i

Integrated IP card for BSC3i and TCSM3i

13

Benefits
Hardware Requirements
Functionality
Planning and dimensioning aspect

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for BSC3i and TCSM3i


Benefits
Ethernet based transmission networks are cheaper that E1/T1
networks comparing the same bandwidths
At the same time, more and more transport resources are
expected to be needed due to:
Availability of services which leads to increase in data rates and in the
amount of transport resources
Collaboration on the same site base station operating in different
technologies (e.g. GERAN, UTRAN )

Exchange Terminal for IP (ETIP) is fully integrated with the existing


HW platform
ETIP (ETIP1-A) is designed in such a way that allows to be used instead
of ETS2 or ET16,
Extends BSC3i/TCSM3i products flexibility and gives operator many new
configuration possibilities
Any mixture of all S14 compatible Exchange Terminals is fully allowed

All these reasons cause that IP over Ethernet BSS interfaces are
supposed to be the most efficient realization of transport
network in GERAN
14

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for


BSC3i and TCSM3i

Integrated IP card for BSC3i and TCSM3i


ETIP1-A plug in unit
ETIP1-A characteristics

15

8+8 ETIP can be installed in Flexi BSC


8+8 ETIP can be installed in BSC3i 1000/2000
4+4 ETIP can be installed in TCSM3i (stand-alone)
126 E1 / 168 T1 per ETIP1-A (in BSC3i)
128 E1/T1 per ETIP1-A (in TCSM3i)
512 different WS (Pseudo Wires)
512 different PSN tunnels
Fast Ethernet / Gigabit Ethernet external connectors
FastE: mainly to be used for local O&M interface
GigE: mainly to be used for PSN interface

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for


BSC3i and TCSM3i

Integrated IP card for BSC3i and TCSM3i


Functionality

Integrated IP card for


BSC3i and TCSM3i

TDM links can be replaced by IP over Ethernet links


Mapping of TDM traffic into IP packets possible thanks to PWE3 (Pseudo
Wire Emulation)
PWE3 is a standardized mechanism which emulates the essential attributes of a service
into Packet Switched Network (PSN).
Different services can be emulated by PWE3 with CESoPSN functionality (i.e.PWE3 of
TDM traffic )

IP solution is applicable for Flexi


BSC, BSC3i, TCSM3i and
FlexiEDGE BTS products
PWE for other elements can be
implemented by additional products
e.g. hiD3105/3140HD.

16

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for


BSC3i and TCSM3i

Integrated IP card for BSC3i and TCSM3i


PWE3 realization in BSS: CESoPSN
CESoPSN functionality

Circuit Emulation Service over PSN performs the following activities:


The TDM bit stream is segmented according to the user specified Time Slot Set (TSS)
bits transmitted by indicated PCM TS in subsequent TDM frames
Headers are added to each segment to form a manageable packet (encapsulation)
Packets are forwarded to the PSN tunnel and transmitted to its destination over Ethernet network
At destination, the original bit stream is reconstructed by removing headers, concatenating
frames and regenerating the timing

an E1 line

a resulting PW (also called CESoPSN packet)

TDM frame #1

Ch24
TS31

TDM frame #2

Ch24
TS31

Ch2
TS1

Ch1
TS0

TDM frame #3

Ch24
TS31

Ch2
TS1

Ch1
TS0

Ch2
TS1

Ch1
TS0

- 3 TDM frames mapped


- PW composed of 31 TS
Ch24
TS31

Ch2
TS2

Ch1
TS1

Ch24
TS31

Ch2
TS2

payload
TSS composed of 31 TS

17

Nokia Siemens Networks

RN20092EN14GLN0

Ch1 TS31
TS1
Ch24

TS2
Ch2

Ch1
TS1

CESoPSN Header

header
Ref. P. Spennemann, Internal Ethernet/IP Interfaces for BSS
Feature Request Sheet, FRS 94060, version 2.0, May 2007

Integrated IP card for BSC3i and TCSM3i


Planning and dimensioning aspects

Integrated IP card for


BSC3i and TCSM3i

Number of ETIP are needed to map the desired TDM traffic into a

PSN using Ethernet links with chosen bandwidth (FE vs. GE) . The
following dimensioning aspects are:
Decide/choose which particular lines shall be mapped to a PSN
Define PWs (from TSS) for each PCM line to be mapped to a PSN
Define how many TDM frames shall be multiplexed within particular
CESoPSN packets
Compute a bandwidth required by each and every PW
Compute the number of required ETIP1-A

BSC3i can have mixture of traditional TDM lines (ET16, ETS2)


and PW lines (ETIP)

18

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for


BSC3i and TCSM3i

Integrated IP card for BSC3i and TCSM3i


Planning and dimensioning aspects
Parameters
The number of consecutive TDM frames per CESoPSN packet (Nf)
The time slot set i.e. the number of TSL from the original E1/T1 (TSS)
Use of VLAN (CESoPSN header 74 octets with VLAN and 70 octets without VLAN)
Required Ethernet bandwidth:

BW / PW [ Mbps ]

8 TSS Nf 8 total _ header _ length


125 Nf

Illustration:

19

Nokia Siemens Networks

RN20092EN14GLN0

TS5

TS6

TS29

TS5

TS6

TS29

Packet
Header

TS5

TS4

TS3

TS2

TS1

TS0

TS31

TS30

TS29

TS6

TS5

TS2

TS4
TS4
TS4

TS3
TS3

TS2

=2
TS1

TS29

TS6

TS5

TS4

TS3

TS2

TS2

TS1

TS29

TS6

TS5

TS3

TS4
TS1

TS29

TS6

TS5

TS4

TS3

TS2

TS1

TS29

TS6

TS5

TS4

TS3

TS2

TS1

2 frames multiplexed, packetization time of 2*125s = 250 s

Packet

TS3

TS0

TS1

TS31

TS30

TS29

TS30

TS31

TS6

TS27

TS28
TS29

TS5

TS4

TS3

TS25

TS26
TS2

TS1

bundle 1 - 29
(CESoPSN)

multiplier
Header

Timeslot allocated for Abis


Timeslot unused

TSx
TSx

bundle 1 - 29
(CESoPSN)
TS29

TS6

TS5

TS4

TS3

TS2

TS1

TS2

TS24
TS0

TS1

TS2

TS23
TS31

TS21

TS18
TS6

TS30

TS17
TS5

TS20

TS16
TS4

TS29

TS15
TS3

bundle 1 - 29
(CESoPSN)
TS29

TS6

TS5

TS4

TS3

TS2

TS1

bundle 1 - 29
(CESoPSN)

TS19

TS13

TS14
TS2

TS12
TS0

TS1

TS11
TS31

TS6

TS9

TS6

TS5

TS10

TS5

TS4

TS30

TS4

TS3

TS8

TS3

TS2

TS29

TS2

TS1

TS7

TS0

TS1

TS0

TS31

TS30

TS29

TDM frame (E1) 32 timeslots 125

Planning and dimensioning aspects


Dimensioning aspects

Calculation example
Given:
-

126 E1 lines to be mapped


1 PW per E1 line (each TSS composed of 31 TSs)
8 TDM frames per packet
CESoPSN header length of 74 bytes (VLAN is enabled)
Gigabit Ethernet and Fast Ethernet links shall be checked

Calculations:
-

packetization latency = 125 Nf = 1000 s (cf. eq. 2) => will be needed for time budget
payload = 8 * TSS * Nf = 1984 bits (cf. eq. 2) => 248 bytes; payload size acceptable
header = 8 * header_length = 592 bits (cf. eq. 2)
BW / PW = (1984 + 592) / 1000 = 2.576 Mbit/s (cf. eq. 1)
OHF = (1984 + 592) / 1984 = 1.29 29% (cf. eq. 4)
BW / PSN = 2.576 * 126 = 324.58 Mbit/s (cf. eq. 7)
GE link load = 324.58 / 1000 = 32.5% => all 126 E1 can be served by 1 ETIP
FE link load = 324.58 / 100 = 324.6 % => not possible!!!
-

20

With FE, 5 ETIP would be needed to handle 126 E1


126 E1 can be handled by 1 ETS2 (with 2 optical interfaces)

Nokia Siemens Networks

RN20092EN14GLN0

Integrated IP card for


BSC3i and TCSM3i

Planning and dimensioning aspects

Integrated IP card for


BSC3i and TCSM3i

Impact on implementation planning

TCSM aspects
Stand-alone TCSM3i has the following characteristics
Comprises of 16 TC2C cartridges in a single Transcoder Cabinet
Each TC2C houses 2 TR3E/TR3A PIUs

One TC2C cartridge can house two extension steps


One TC2C cartridge consist of up to 16 TR3E/TR3A units each up to 120 channels plus selected interface cards

Each TR3x has the following transcoding capacity:

TR3E: 960 TCH ETSI (8 E1 Ater lines)


TR3A: 768 TCH ANSI (8 T1 Ater lines)

Fully equipped TCSM3i can support:

6 TC2C 2 TR3E 960 = 11520 TCH ETSI


6 TC2C 2 TR3A 768 = 9216 TCH ANSI
6 TC2C 2 TR3E 8 Ater lines = 96 E1/T1 Ater 384 E1/T1 A-IF
up to 24 BSC can be connected to a single TCSM3i cabinet

Implementation of CESoPSN in TCSM3i


4 (active + spare) ETIP1-A can be installed in TCSM3i:

1 ETIP is used to handle Ater interface


3 ETIP are used to handle A interface, one ETIP can serve 2 (adjacent) TC2C

Ref. P. Koski, M. Saukko, H. Tervonen, J. Toivinen,


PWE Transport Support in BSC3i and TCSM3i,
Requirements Specification, BSS21157, version 1.1.0, January 2008

If the whole Ater is over IP the Ater ETIP in TCSM3i has to be configured as a synch master and an
ETIP in the BSC as a synch slave.

21

Nokia Siemens Networks

RN20092EN14GLN0

Planning and dimensioning aspects

Integrated IP card for


BSC3i and TCSM3i

Impact on implementation planning

Redundancy aspects
ETIP1-A PIU is represented by functional unit ETIP
Redundancy implementation concept are:
HW protection (N+N, active PIU has its own spare one)
Line protection (each board has two individual Ethernet interfaces while only one of them is
active at the time)

IP addressing
IP addresses of the devices installed in FlexiBTS, BSC3i, TCSM3i are used
during creation of PSN tunnel and its PWs: any mismatch is to be avoided

22

Nokia Siemens Networks

RN20092EN14GLN0

BSS14 for Network Planners

PCU2 HW Evolution
and Asymmetrical

Hardware Support
Flexi BSC and Double Capacity AS7 Unit.
Integrated IP card for BSC3i and TCSM3i
PCU2 HW Evolution and Asymmetrical PCU HW configuration

23

Nokia Siemens Networks

RN20092EN14GLN0

PCU2 HW Evolution
and Asymmetrical

PCU2 HW Evolution and Asymmetrical PCU HW configuration


Benefits
Configuration and capacity
Dimensioning rules (connectivity and asymmetrical setup)
Modified parameters, new alarms

24

Nokia Siemens Networks

RN20092EN14GLN0

PCU2 HW Evolution and Asym. PCU HW config.


Benefits

PCU2 HW Evolution
and Asymmetrical

PCU related S14 features are expected to bring the following benefits
PCU2-E

Allows to increase packet data capacity within the same space


Optimized for Flexi BSC
Supports higher user peak rates
Better Gb link utilization. More cells per PCU gives better multiplexing gain in Gb.

Asymmetrical PCU HW configuration


Optimizes and simplifies PCU usage in different BCSU
Less PCU plug in units needed with the feature
Its benefit can be immediately seen in the scenarios like:
PCU capacity extension (in a single BCSU):
user needs to add only 1 single PCU to the BCSU where insufficient PCU capacity is observed
TRX capacity extension:
user needs to add another BCSU (without or with minimum PCU configuration)
Various amount of PCUs in different BCSU

25

Nokia Siemens Networks

RN20092EN14GLN0

Benefits of PCU2-E

PCU2 HW Evolution
and Asymmetrical

PCU2-E can also be used in the BSC3i 660 and BSC3i


1000/2000
Performance improvement is a prime reason to install PCU2-E in BSC3i
types
Mixture of PCU2-E and PCU2-D is possible within BSC3i
Due to different internal structure in BSC3i and Flexi BSC the PCU2-E can
reach half of its max possible capacity in when used in BSC3i
660/1000/2000
PCU2-E can handle up to 512 Abis channels in BSC3i 660/1000/2000

26

Nokia Siemens Networks

RN20092EN14GLN0

PCU2 HW Evolution
and Asymmetrical

Characteristics of PCU2-E
PCU2-E capacity

PCU2-E capacity is collected in the table below together with the respective values of
PCU2-D for comparison

The capacities below are achievable per logical PCU in Flexi BSC
Parameter

PCU2-E

PCU2-D

#logical PCU

#Abis channels

1024

256

#BTS objects

384

128

#EGPRS cells

256

64

#GPRS/EGPRS TRX

1024 / 720

256 / 192

#EDAP

60

16

#BCF

384

128

Note: PCU2-D capacity figures are maintained in RG10 in comparison to S13 ones

27

Nokia Siemens Networks

RN20092EN14GLN0

PCU2 HW Evolution
and Asymmetrical

Gb interface capacity for PCU2-E and PCU2-D

Parameter
# max Gb throughput per logical PCU )*
# of bearer channels per logical PCU
capacity per FR link
Total rate of FRLs / logical PCU

PCU2-E
8 Mbps (128 TSL x 64 kbps)
16 FRL/NS-VC
131 TSL (1984 kbps)
128 x 64 kbps

PCU2-D
2 Mbps (32 TSL x 64 kbps)
4 FRL/NS-VC
131 TSL (1984 kbps)
32 x 64 kbps

*) incl. both user traffic and overheads

Overall, applicable for both PCU2-E / PCU2-D


Max Gb throughput can be reached with more than 1 FRL
Gb over FR: capacity of the Frame Relay links may limit the PCU throughput
Gb over IP: Gb connectivity does not limit the PCU throughput

28

Nokia Siemens Networks

RN20092EN14GLN0

Possible configuration of PCU2-E

PCU2 HW Evolution
and Asymmetrical

PCU2-E can be installed in Flexi BSC and any BSC3i but certain additional rules exist
BSC type

max #PCU2-E
per BCSU

#Abis channels
per PCU2-E

#active BCSU per BSC /


#logical PCU per BSC

Abis bw in max conf

BSC3i 660

1 (not 2)

512

6/6

~ 98 Mbps

BSC3i 1000

3 (not 5)

512

5 / 15

~204 Mbps

BSC3i 2000

3 (not 5)

512

10 / 30

~ 409 Mbps

Flexi BSC

1024

6 / 30

~ 491 Mbps

PCU2-E can be installed neither in BSCi nor in BSC2i


There are 2 rules to be considered when using PCU2-E in BSC3i 660/1000/2000
Limited number of PCU slots in BCSU can host PCU2-E due to limitations of power supply
and cooling systems
512 Abis channels can be reached due to connectivity implementation in BSC3i
660/1000/2000

29

Nokia Siemens Networks

RN20092EN14GLN0

Mixed PCU configuration

PCU2 HW Evolution
and Asymmetrical

Different amount of PCUs in different BCSUs of the same BSC or different


PCU HW variants in the same slots of different BCSUs

mixed PCU configuration is possible however some restrictions exist, i.e.


the following mixtures are allowed within the same BCSU track of different
BCSU
PCU, PCU-S, PCU-T, PCU2-U, empty slot
PCU-B, PCU2-D, empty slot
PCU2-E, empty slot

Mixed PCU configuration in such context is a new functionality that


leads to asymmetrical PCU configuration

30

Nokia Siemens Networks

RN20092EN14GLN0

Asymmetrical PCU configuration

PCU2 HW Evolution
and Asymmetrical

Asymmetrical PCU configuration is available as a


separate RG10 feature

Before the feature:


- Each BCSU in the BSC is equipped with the same PCU configuration

(number of PCUs and their type)


For e.g. lets assume a BSC3i 2000 equipped with 10 (active) BCSUs
and 1 PCU in each BCSU
Lets say that 1 out of 10 BCSUs needs another PCU to be installed
(due to PS traffic)
To do so, each and every BCSU would need to have second PCU
installed
10 extra PCUs are needed in case of fully equipped BSC3i 2000 to add
1 PCU in 1 BCSU

31

Nokia Siemens Networks

RN20092EN14GLN0

Asymmetrical PCU configuration


With the feature:
- PCU can be installed and activated according to actual traffic
needs with granularity 1 in every BCSU separately

- Each active BCSU can have different number of PCUs

(depending on actual traffic requirements), i.e. it may happen


that some BCSU have no PCU units while the other ones
have some PCU installed

- Different PCU types can be mixed in the same BSC/BCSU


(restrictions concerning the same BCSU track exist -> see
previous slide)

- BCSU which is marked as primary spare must

be equipped with the number of PCU sufficient to replace any


of the active BCSU

32

Nokia Siemens Networks

RN20092EN14GLN0

PCU2 HW Evolution
and Asymmetrical

PCU2 HW Evolution
and Asymmetrical

for spare BCSU


In maximum four PCU2 BSW licenses per one PCU2-E HW
plug-in unit
One PCU2 BSW license = 256 Abis channels (16 kbit/s)

Example :
Minimum configuration for 1 BSC =>
1 + 1 PCU2-E HW units + one PCU2 BSW license

PCU2-E HW

PCU2 BSW
PCU2 BSW
PCU2 BSW
PCU2 BSW

PCU2-E HW

OPTIONAL
activated according
traffic requirements

For E.g. with Flexi BSC and with Asymmetrical PCU HW


Configuration
PCU2-E HW is installed according traffic requirements
PCU2-E SW is activated according traffic requirements
In minimum one PCU2-E HW unit + one PCU2-E HW unit

OPTIONAL activated
according traffic requirements

PCU2 HW and SW Activation in S14

PCU2-E HW

PCU2 BSW
PCU2 BSW
PCU2 BSW
PCU2 BSW
PCU2 BSW
PCU2 BSW
PCU2 BSW
PCU2 BSW

Spare BCSU

PCU2-E HW

33

Nokia Siemens Networks

RN20092EN14GLN0

PCU2-E Dimensioning

PCU2 HW Evolution
and Asymmetrical

Impact of PCU2-E introduction on PCU dimensioning/planning


Overall PCU HW requirements for BSS14
All existing PCU units (PCU1, PCU2) could still be used with the basic S14 SW
release
All new packet data related application SW features would require PCU2

Impact of introduction of PCU2-E on PCU dimensioning


- Dimensioning concept does not need to be modified
- All static limits must be checked against the corresponding values determined
per BSC (planning area)
- Utilization rate should be additionally taken into account
- The basic formula used for PCU dimensioning is


N Abis _ ch,BSC


NBTS,BSC
NTRX,BSC
NEDAP,BSC
NBCF,BSC
NPCU2E,BSC max
;
;
;
;
;...
UR Abis _ ch max N Abis _ ch,PCU2E max NBTS,PCU2E max NTRX,PCU2E max NEDAP,PCU2E max NBCF,PCU2E

34

Nokia Siemens Networks

RN20092EN14GLN0

PCU2 HW Evolution
and Asymmetrical

Parameters

No new parameters
Modified parameters: only ranges of those parameters that are explicitly dependent on

modified static limits should be subject to modification, e.g. new PCU variant (PCU2-E)
must be configurable in addition to former types

Parameter name
(abbreviation)

Range and step, default value

Description

Object
name

Plug-in Unit Type


(piuType)

Range: 276 (pcu_c),


365 (pcu_s_c), 379 (pcu_t_c), 398
(pcu2_u_c), 979 (pcu_b_c), 985
(pcu2_d_c),
995 (pcu2_e_c),
1023 (no_piu_type_info_c)
Default: 1023

PCU plug-in unit type. The attribute describes the PCU HW variant.

PCU

Bearer Channel
Identifier
(frBearerChannelId)

Range: 0479
Step: 1
Default: -

Bearer channel identifier. The attribute allows to define the bearer channel ID.

NSVC,
FRBC

35

Nokia Siemens Networks

RN20092EN14GLN0

Note! Range:
0..95 for BSC3i 660
0..399 for BSC3i 2000
0..479 for BSC3i 3000 (6 BCSU/BSC 5 PCU2-E/BSCU 16 FRLorNSVC/PCU)
0..63 for other BSCs

Counters and alarms

PCU2 HW Evolution
and Asymmetrical

PCU2-E requires no new counters nor measurements (apart from FRL


measurement), it does not affect functional triggering points either)

- only the amount of FRL measurements is extended due to increase in the number of FRL supported

No new alarms are introduced due to PCU2-E


- only the amount of alarms (since the alarm count parameter is generally scaled according to the number of

object instances raising the alarm) is to be extended (e.g. EGPRS DYNAMIC ABIS POOL FAILURE from 16
to 60 objects)

New alarms related to Asymmetrical PCU configuration


- primary_spare_bcsu_missing_a: PCU configuration of BSC is asymmetrical and primary spare BCSU unit
definition is missing
- primary_spare_bcsu_invalid_a: Primary spare BCSU unit PCU configuration is invalid. Primary spare
BCSU unit can not replace all BCSUs

36

Nokia Siemens Networks

RN20092EN14GLN0

Thank you
for your attention!

37

Nokia Siemens Networks

RN20092EN14GLN0

You might also like