Professional Documents
Culture Documents
BY
ROUTHU SATYANARAYANA
FORMER CHIEF ENGINEER
FORMER ADVISOR, GOVERNMENT OF A.P
Modular Outlets
DESIGN - EXAMPLES
HYDRAULIC DESIGN
OFM APM - PSM
proportional
Module
Modular Outlets
The suitability of the type of the semi module outlet is determined based on the ratio of parent
canal discharge (Q) to the discharge of the out let (q) and the throat width (Bt) as detailed
below.
i) for (Q/q ) < or = 20 and B t 6 cm
If the above requirements do not suit the site condition, provide pipe semi module (where
possible) with diaphragm of required diameter inserted at the first joint. The minimum diameter
of pipe used will be 150 mm.
Modular Outlets
Details
Parent Canal
Off Take
Kopparam
Major
13 R Minor
0.939
1.200
0.730
0.610
2640
1.5 : 1
0.561
0.020
81.589
0.080
0.300
0.310
0.460
2000
1.5 : 1
0.339
0.020
81.662
82.319
81.972
82.929
82.432
82.929
82.432
Unit
Cumecs
m
m
m
1 in
m/sec
Design of OFM
Hydraulic Design:
Ratio of Q/q = 0.939 / 0.08
= 11.738 < 20
Hence O.F.M. is Proposed.
FSD in the parent channel, D = 0.730 m
Depth of flow in the parent channel at 2/3 rd discharge:
Dn = 0.594 m (assumed)
For 2/3rd Discharge in Parent Canal Q n = 2/3 x Q = 0.626 cumecs
Let Dn = 0.594 m , Area = 1.242 m2
Perimeter = 3.342 m, R = 0.372, and R2/3 = 0.517
Velocity = 0.504 m/sec
Discharge = 0.626 cumecs
Hence Dn i.e., depth of flow of 0.594 m in the parent channel assumed for
2/3rd discharge is correct.
Difference in depths of flow for full discharge and 2/3 rd discharge
x = D - Dn = 0.730 - 0.594 = 0.136 m
Design of OFM
Hs 0.80 D
y
> (2/3 ) H
Setting of crest, H = 0.750 x D , where D = Full supply depth in the parent
canal
Setting of crest shall not be below D/S B.L.
Design of APM
Hydraulic Particulars:
S.No. Details
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Kuppam Major
DP 17-R
At FS Discharge Condition
0.018
0.300
0.150
2000
0.020
0.231
1.5 : 1
0.450
80.422
80.572
81.022
81.489
Kuppam major
DP 17-R
At 2/3 FS Discharge Condition
0.424
1.100
0.495
2500
0.020
0.464
1.5 : 1
0.610
80.269
80.764
0.012
0.300
0.120
2000
0.020
0.183
1.5 : 1
0.450
80.422
80.542
Design of APM
Design of APM
Design of APM
--------------equation (1)
--------------equation (2)
Design of APM
Y = q / 4.03xBtx(Hs)1/2
= 0.018 / 4.03 x 0.06 x 0.455
Y = 0.164 m
say 0.165 m
Q = 4.03 Bt Y ( Hs )
= 4.03 x 0.06 x 0.165 x 0.455 = 0.018 cumecs
qn = 4.03 Bt Y ( Hsn )
= 4.03 x 0.06 x 0.165 x 0.303 = 0.012 cumecs
The following Parameters may be adopted
Bt = 0.060 m
Crest Level =
U/S FSL - H = + 80.507
H = 0.372 m
Y = 0.165 m
Hs = 0.207 m
W= Setting forward of the D/S wing wall of the approach =0.15
The setting of the Wing wall W = K q/Q (Bu + D/2)
Design of APM
Design criteria
The discharge through pipe semi module is given by
Q = Cd . A (2g hc )1/2
Where Cd = 0.62 for free pipe out let
hc = head on U/S above the centre of pipe
hc should be more than 1.5 times the dia of the pipe proposed.
The above formulae can be reduced to
Q = 0.62 x (2x 9.81 ) A (hcnt)
=2.746 A hc 1/2
For free fall condition set the F.S.L of OT Channel below the pipe sill level keeping in view
the command under the pipe sluice .It is a simplest type and the users will appreciate.
Modular Outlets
DESIGN OF PIPE SEMI MODULE (for DIRECT OUTLET )
HYDRAULIC PARTICULARS
DESCRIPTION
UNIT `
PARENT CHANNEL
1 Ayacut
Acres
597.0
PARTICULARS
OUTLET CHANNEL
75.00
0.2370 / 0.3460
3 Bed width
1.100
0.300
0.500
0.220
5 Free board
0.300
0.300
1.50 / 2 : 1 1.50 / 2 : 1
4.000 / 2.50
8 C.B.L.
+ 473.655 + 473.500
9 F.S.L.
+ 474.155 + 473.720
10 T.B.L.
+ 474.455 + 474.020
11 G.L.
+ 474.855 + 474.855
0.030 / 0.033
0.900 / 0.900
Modular Outlets
Discharge through the Pipe Outlet by using Orifice formula:
Q = CA (2g hcnt)1/2
where C = 2. 476
Q = Discharge of Out Let
A = Cross section Area of Pipe
h(cnt) = Head of U/s water surface over the center of pipe
Q = CA (2g hcnt)1/2
Where C = 2.476
Provide Dia of Pipe = 16 cm
Area A = 0.020 m2
Q = 0.033 cumec
hcnt = Q CA 2
= 0.033 2.476x0.02
= 0.350 m > 1.5 times dia of pipe
Provide did. of pipe = 200mm
Design of PSM
THANK YOU