You are on page 1of 43

An Introduction to S-parameters

S-parameters
Whilst reading through this document you may find it useful to have access to the
Polar Si9000e PCB Transmission Line Field Solver, as this will aid your
understanding of S-parameters. Evaluation licenses are available from our
offices, contact details can be found on slide 43.

www.polarinstruments.com

S-parameters
S-parameters are a useful method for representing a circuit as a black box

www.polarinstruments.com

S-parameters
S-parameters are a useful method for representing a circuit as a black box

The external behaviour of this


black box can be predicted
without any regard for the contents
of the black box.

www.polarinstruments.com

S-parameters
S-parameters are a useful method for representing a circuit as a black box

The external behaviour of this


black box can be predicted
without any regard for the contents
of the black box.
This black box could contain
anything:
a resistor,
a transmission line
or an integrated circuit.

www.polarinstruments.com

S-parameters
A black box or network may have any number of ports.

This diagram shows a simple


network with just 2 ports.

www.polarinstruments.com

S-parameters
A black box or network may have any number of ports.

This diagram shows a simple


network with just 2 ports.

Note :
A port is a terminal pair of lines.

www.polarinstruments.com

S-parameters
S-parameters are measured by sending a single frequency signal into the
network or black box and detecting what waves exit from each port.

Power, voltage and current


can be considered to be in
the form of waves travelling
in both directions.

www.polarinstruments.com

S-parameters
S-parameters are measured by sending a single frequency signal into the
network or black box and detecting what waves exit from each port.

Power, voltage and current


can be considered to be in
the form of waves travelling
in both directions.

For a wave incident on Port 1,


some part of this signal
reflects back out of that port
and some portion of the signal
exits other ports.

www.polarinstruments.com

S-parameters
I have seen S-parameters described as S11, S21, etc. Can you explain?

First lets look at S11.


S11 refers to the signal
reflected at Port 1 for the
signal incident at Port 1.

10

www.polarinstruments.com

S-parameters
I have seen S-parameters described as S11, S21, etc. Can you explain?

First lets look at S11.


S11 refers to the signal
reflected at Port 1 for the
signal incident at Port 1.
Scattering parameter S11
is the ratio of the two
waves b1/a1.

11

www.polarinstruments.com

S-parameters
I have seen S-parameters described as S11, S21, etc. Can you explain?

Now lets look at S21.


S21 refers to the signal
exiting at Port 2 for the
signal incident at Port 1.
Scattering parameter S21
is the ratio of the two
waves b2/a1.

12

www.polarinstruments.com

S-parameters
I have seen S-parameters described as S11, S21, etc. Can you explain?

Now lets look at S21.


S21 refers to the signal
exiting at Port 2 for the
signal incident at Port 1.
Scattering parameter S21
is the ratio of the two
waves b2/a1.

13

S21? Surely that should be S12??

www.polarinstruments.com

S-parameters
I have seen S-parameters described as S11, S21, etc. Can you explain?

Now lets look at S21.


S21 refers to the signal
exiting at Port 2 for the
signal incident at Port 1.
Scattering parameter S21
is the ratio of the two
waves b2/a1.

14

S21? Surely that should be S12??


S21 is correct! S-parameter
convention always refers to the
responding port first!
www.polarinstruments.com

S-parameters

15

www.polarinstruments.com

S-parameters
I have seen S-parameters described as S11, S21, etc. Can you explain?
A linear network can be characterised by a set of simultaneous equations
describing the exiting waves from each port in terms of incident waves.
S11 = b1 / a1
S12 = b1 / a2
S21 = b2 / a1
S22 = b2 / a2
Note again how the subscript follows the parameters in the ratio (S11=b1/a1, etc...)

16

www.polarinstruments.com

S-parameters

17

www.polarinstruments.com

S-parameters

S-parameters are complex (i.e. they have magnitude and angle)


because both the magnitude and phase of the input signal are
changed by the network.
(This is why they are sometimes referred to as complex scattering parameters).

18

www.polarinstruments.com

S-parameters

These four S-parameters actually contain eight separate numbers:


the real and imaginary parts (or the modulus and the phase angle)
of each of the four complex scattering parameters.

19

www.polarinstruments.com

S-parameters

Quite often we refer to the magnitude only as it is of the most interest.


How much gain (or loss) you get is usually more important than how much
the signal has been phase shifted.

20

www.polarinstruments.com

S-parameters
What do S-parameters depend on?
S-parameters depend upon the network
and the characteristic impedances of the
source and load used to measure it, and
the frequency measured at.
i.e.
if the network is changed, the S-parameters change.
if the frequency is changed, the S-parameters change.
if the load impedance is changed, the S-parameters change.
if the source impedance is changed, the S-parameters change.

21

www.polarinstruments.com

S-parameters
What do S-parameters depend on?
S-parameters depend upon the network
and the characteristic impedances of the
source and load used to measure it, and
the frequency measured at.
i.e.
if the network is changed, the S-parameters change.
if the frequency is changed, the S-parameters change.

In the Si9000e
if the load impedance is changed, the S-parameters
change.

the source and load


impedance default is 50 Ohms,
if the source impedance is changed, the S-parameters change.
although this is configurable.
22

www.polarinstruments.com

S-parameters
What do S-parameters depend on?
S-parameters depend upon the network
and the characteristic impedances of the
source and load used to measure it, and
the frequency measured at.
i.e.
if the network is changed, the S-parameters change.
if the frequency is changed, the S-parameters change.
if the load impedance is changed, the S-parameters change.
if the source impedance is changed, the S-parameters change.

23

www.polarinstruments.com

S-parameters
A little math
This is the matrix algebraic representation
of 2 port S-parameters:

Some matrices are symmetrical. A symmetrical matrix has symmetry about


the leading diagonal.

24

www.polarinstruments.com

S-parameters
A little math
This is the matrix algebraic representation
of 2 port S-parameters:

Some matrices are symmetrical. A symmetrical matrix has symmetry about


the leading diagonal.
In the case of a 2-port network, that means that S21 = S12 and interchanging
the input and output ports does not change the transmission properties.

25

www.polarinstruments.com

S-parameters
A little math
This is the matrix algebraic representation
of 2 port S-parameters:

Some matrices are symmetrical. A symmetrical matrix has symmetry about


the leading diagonal.
In the case of a symmetrical 2-port network, that means that S21 = S12 and
interchanging the input and output ports does not change the transmission
properties.
A transmission line is an example of a symmetrical 2-port network.

26

www.polarinstruments.com

S-parameters
A little math
Parameters along the leading diagonal,
S11 & S22, of the S-matrix are referred to as
reflection coefficients because they refer to
the reflection occurring at one port only.

27

www.polarinstruments.com

S-parameters
A little math
Parameters along the leading diagonal,
S11 & S22, of the S-matrix are referred to as
reflection coefficients because they refer to
the reflection occurring at one port only.

Off-diagonal S-parameters, S12, S21, are referred to as transmission coefficients


because they refer to what happens from one port to another.

28

www.polarinstruments.com

S-parameters
Larger networks:
A Network may have any number of ports.

29

www.polarinstruments.com

S-parameters
Larger networks:
A Network may have any number of ports.

The S-matrix for an n-port network contains n2 coefficients (S-parameters),


each one representing a possible input-output path.

30

www.polarinstruments.com

S-parameters
Larger networks:
A Network may have any number of ports.

The S-matrix for an n-port network contains n2 coefficients (S-parameters),


each one representing a possible input-output path.
The number of rows and columns in an S-parameters matrix is equal to the
number of ports.

31

www.polarinstruments.com

S-parameters
Larger networks:
A Network may have any number of ports.

The S-matrix for an n-port network contains n2 coefficients (S-parameters),


each one representing a possible input-output path.
The number of rows and columns in an S-parameters matrix is equal to the
number of ports.
For the S-parameter subscripts ij, j is the port that is excited (the input port)
and i is the output port.

32

www.polarinstruments.com

S-parameters
Larger networks:
A Network may have any number of ports.

Yes i for output j for input


logical ;-)

The S-matrix for an n-port network contains n2 coefficients (S-parameters),


each one representing a possible input-output path.
The number of rows and columns in an S-parameters matrix is equal to the
number of ports.
For the S-parameter subscripts ij, j is the port that is excited (the input port)
and i is the output port.

33

www.polarinstruments.com

S-parameters
Larger networks:
A Network may have any number of ports.

The S-matrix for an n-port network contains n2 coefficients (S-parameters),


each one representing a possible input-output path.
The number of rows and columns in an S-parameters matrix is equal to the
number of ports.
For the S-parameter subscripts ij, j is the port that is excited (the input port)
and i is the output port.

34

www.polarinstruments.com

S-parameters

35

www.polarinstruments.com

S-parameters
Sum up

S-parameters are a powerful way to describe an electrical network


S-parameters change with frequency / load impedance / source impedance / network
S11 is the reflection coefficient
S21 describes the forward transmission coefficient (responding port 1st!)
S-parameters have both magnitude and phase information
Sometimes the gain (or loss) is more important than the phase shift and the phase
information may be ignored
S-parameters may describe large and complex networks
If you would like to learn more please consider evaluating the Polar Si9000e PCB
Transmission Line Field Solver. A 5 step process to generate, plot and export Sparameters is included in the following slides.

36

www.polarinstruments.com

S-parameters
Using Polar Si9000e Field Solver to generate, plot and export S-parameters
Step 1: Select the transmission line structure and enter the parameters

37

www.polarinstruments.com

S-parameters
Using Polar Si9000e Field Solver to generate, plot and export S-parameters
Step 2: Switch to the Frequency Dependent tab and enter the frequency range

38

www.polarinstruments.com

S-parameters
Using Polar Si9000e Field Solver to generate, plot and export S-parameters
Step 3: Select Calculate to generate S-parameters and plot graph

39

www.polarinstruments.com

S-parameters
Using Polar Si9000e Field Solver to generate, plot and export S-parameters
Step 4: The S-parameter data may be plotted in a number of useful ways

40

www.polarinstruments.com

S-parameters
Using Polar Si9000e Field Solver to generate, plot and export S-parameters
Step 5: The same S-parameter data may be exported to a number of formats

Touchstone

Excel

.CSV

41

www.polarinstruments.com

S-parameters
Further reading:
Agilent papers
http://www.sss-mag.com/pdf/an-95-1.pdf
http://www.sss-mag.com/pdf/AN154.pdf
National Instruments paper
http://zone.ni.com/devzone/nidzgloss.nsf/webmain/D2C4FA88321195FE86256
86B00542EDB?OpenDocument
Other links:
http://www.sss-mag.com
http://www.microwaves101.com/index.cfm
http://www.reed-electronics.com/tmworld/article/CA187307.html
http://en.wikipedia.org/wiki/S-parameters
Online lecture OLL-140 Intro to S-parameters - Eric Bogatin
Online lecture OLL-141 S11 & Smith charts - Eric Bogatin
www.bethesignal.com
42

www.polarinstruments.com

S-parameters

For more information:


Contact Polar now:
USA / Canada / Mexico
Ken Taylor
Asia / Pacific
Terence Chew
Japan
Terumitsu Tsuji

Phone

( 503) 356 5270


+65 6873 7470
+81 45 339 0155

UK / Europe
Neil Chamberlain

+44 23 9226 9113

Germany / Austria / Switzerland


Hermann Reischer

+43 7666 20041-0

www.polarinstruments.com

43

www.polarinstruments.com

You might also like