FIRE MENU Normal Operation 1/20

One of the first things to do before


the first flight of the day is the APU
FIRE Test.

FIRE MENU Normal Operation 2/20


Before you can perform this test,
you have to make sure that:
- the APU FIRE pb sw is in and
guarded
- the AGENT light is extinguished.

FIRE MENU Normal Operation 3/20


Let's perform the test now!

Push the APU FIRE TEST pb.

FIRE MENU Normal Operation 4/20


Let's perform the test now!

No, push the APU FIRE TEST pb.

FIRE MENU Normal Operation 5/20


Let's perform the test now!

No, push the APU FIRE TEST pb.

FIRE MENU Normal Operation 6/20


FIRE MENU Normal Operation 7/20
FIRE MENU Normal Operation 8/20
Observe:
- the APU FIRE pb sw illuminates
red
- SQUIB and DISCH lights come on.
Additionally if AC power is
available, you get the MASTER WARN
light, the CRC and an APU FIRE
warning on the ECAM.

FIRE MENU Normal Operation 9/20


Before you leave the cockpit to
perform the walk-around, you have to
check the emergency equipment.
Ensure that the fire extinguisher
pressure is in the green area.

FIRE MENU Normal Operation 10/20


During the walk-around, you have
to check that the APU Fire
extinguisher overpressure indication
(red disc) is in place. This is an
indication that the fire bottle has not
been discharged.

Note: there is no such indication for


the engine fire bottles.

FIRE MENU Normal Operation 11/20


Back in the cockpit, we proceed with the
ENG FIRE test.
We will do ENG 1 only, the test for ENG 2
is the same.

Note: These tests are not necessary during a


transit check

Push the ENG 1 FIRE TEST pb.

FIRE MENU Normal Operation 12/20


Back in the cockpit, we proceed with the
ENG FIRE test.
We will do ENG 1 only, the test for ENG 2
is the same.

Note: These tests are not necessary during a


transit check

No, push the ENG 1 FIRE TEST pb.

FIRE MENU Normal Operation 13/20


Back in the cockpit, we proceed with the
ENG FIRE test.
We will do ENG 1 only, the test for ENG 2
is the same.

Note: These tests are not necessary during a


transit check

No, push the ENG 1 FIRE TEST pb.

FIRE MENU Normal Operation 14/20


FIRE MENU Normal Operation 15/20
FIRE MENU Normal Operation 16/20
FIRE MENU Normal Operation 17/20
FIRE MENU Normal Operation 18/20
FIRE MENU Normal Operation 19/20
Observe:

- the ENG 1 FIRE pb sw illuminates red


- SQUIB and DISCH lights come on
- the MASTER WARN light illuminates red
- the CRC sounds
- the ENG 1 FIRE warning on the ECAM
appears
- the FIRE light on the ENG panel illuminates.

Module completed

FIRE MENU Normal Operation 20/20 NEXT


LIST OF SUBJECTS
APU FIRE TEST
ENG 1 FIRE TEST

AUDIO GLOSSARY FCOM

RETURN EXIT